Skip to content

Innovair vs JANITROL heat pumps

Measured against models of the same size and duct type, Innovair scores higher on 5 of the 6 ratings. Innovair has 48 outdoor models, JANITROL has 47 outdoor models. JANITROL has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Innovair and JANITROL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Innovair scores higher on 5 of the 6 ratings.
  • Innovair
  • JANITROL
  • Other ranked manufacturers
InnovairJANITROL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingInnovairJANITROL
Efficiency index50% (higher)median — · 19th ranked39% (higher)median —
COP at 5°F45% (higher)median 1.90 · 23rd ranked40% (higher)median 1.92
Capacity retention at 5°F58% (higher)median 75% · 10th ranked14% (higher)median 46%
HSPF249% (higher)median 8.7 · 16th ranked21% (higher)median 7.0
SEER247% (higher)median 17.0 · 16th ranked30% (higher)median 15.2
EER241%median 10.5 · 25th ranked67%median 11.4
Heating capacity at 5°F59% (higher)median 19,400 Btu/h · 7th ranked14% (higher)median 15,200 Btu/h
Outdoor models4847
AHRI certifications953,377

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardInnovairJANITROL
CEE 2025 Tier 1 (Split ASHP)50%24 models6.4%3 models
CEE 2026 Tier 1 (Split ASHP)45.8%22 models2.1%1 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)43.8%21 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate47.9%23 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 5 groups where both have models
  • Innovair
  • JANITROL
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeInnovairJANITROL
Ducted, up to 1.5 tons5 · index 54%3 · index 39%
Ducted, 2 tons5 · index 63%8 · index 38%
Ducted, 2.5 to 3 tons7 · index 51%15 · index 39%
Ducted, 3.5 to 4.5 tons6 · index 54%19 · index 42%
Ducted, 5 tons and up1 · index 42%2 · index 37%
Non-ducted, up to 1.5 tons14 · index 50%None
Non-ducted, 2 tons5 · index 55%None
Non-ducted, 2.5 to 3 tons8 · index 35%None
Non-ducted, 3.5 to 4.5 tons1 · index 44%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeInnovairCold-climate score, best modelJANITROLCold-climate score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R194 of 5 models qualify · AHRI 213255597None on this board (0 of 3 models qualify)
Ducted, 2 tons75.7(50 is the typical model of its size class)MHD-24with ducted air handler MHD-CC2.0-17.5-M4 of 5 models qualify · AHRI 210365430None on this board (0 of 8 models qualify)
Ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class)SHV36H2R20with ducted air handler MAC36H2124E4 of 7 models qualify · AHRI 213160476None on this board (0 of 15 models qualify)
Ducted, 3.5 to 4.5 tons74.0(50 is the typical model of its size class)SHV48H2R20with ducted air handler DEV48H2R193 of 6 models qualify · AHRI 210343157None on this board (0 of 19 models qualify)
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons80.8(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 14 models qualify · AHRI 206330207No models in this size class
Non-ducted, 2 tons69.9(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models qualify · AHRI 206330210No models in this size class
Non-ducted, 2.5 to 3 tons65.0(50 is the typical model of its size class)VOM36H7R4P71 of 8 models qualify · AHRI 207821954No models in this size class
Non-ducted, 3.5 to 4.5 tons41.8(50 is the typical model of its size class)VOM42H7R5P71 of 1 models qualify · AHRI 207821958No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeInnovairAll-around score, best modelJANITROLAll-around score, best model
Ducted, up to 1.5 tons82.9(50 is the typical model of its size class) (higher)SHV18H2R20with ducted air handler WEV18H2R195 of 5 models have all five ratings · AHRI 21325559740.3(50 is the typical model of its size class)GSZB401810A*with indoor coil CAPTA3626*4A and furnace GM9S960403BUAAlso listed as GSZM401810A3 of 3 models have all five ratings · AHRI 212836164
Ducted, 2 tons71.7(50 is the typical model of its size class) (higher)VOM24H7R3P75 of 5 models have all five ratings · AHRI 20782195059.1(50 is the typical model of its size class)GSZC702410A*with ducted air handler AMVT30BP1400A6 of 8 models have all five ratings · AHRI 211945057
Ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class) (higher)VOM36H7R4P77 of 7 models have all five ratings · AHRI 20782195364.3(50 is the typical model of its size class)GSZC703610A*with ducted air handler CAPTA4230*4A*+MBVC2001**-1A11 of 15 models have all five ratings · AHRI 211945087
Ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class)VOM42H7R5P76 of 6 models have all five ratings · AHRI 20782195668.4(50 is the typical model of its size class) (higher)GSZC704810A*with ducted air handler CAPT4961*4A*+MBVC2001**-1A10 of 19 models have all five ratings · AHRI 211945125
Ducted, 5 tons and up41.9(50 is the typical model of its size class)SEV60H2R19with ducted air handler DEV60H2R191 of 1 models have all five ratings · AHRI 20810686352.1(50 is the typical model of its size class) (higher)GPHH56041A*2 of 2 models have all five ratings · AHRI 211944535
Non-ducted, up to 1.5 tons89.1(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)11 of 14 models have all five ratings · AHRI 206330207No models in this size class
Non-ducted, 2 tons77.1(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)4 of 5 models have all five ratings · AHRI 206330210No models in this size class
Non-ducted, 2.5 to 3 tons70.2(50 is the typical model of its size class)VOM36H7R4P77 of 8 models have all five ratings · AHRI 207821954No models in this size class
Non-ducted, 3.5 to 4.5 tons44.4(50 is the typical model of its size class)VOM42H7R5P71 of 1 models have all five ratings · AHRI 207821957No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingInnovairJANITROL
COP at 5°Fbeats 91% · 2.37VEA36H2V18Ducted, 2.5 to 3 tonsbeats 95% · 2.51GPHH56041A*Ducted, 5 tons and up
Capacity retention at 5°Fbeats 99% · 144%EIN10H2V32(O)Non-ducted, up to 1.5 tonsbeats 39% · 60%GSZC706010A*Ducted, 3.5 to 4.5 tons
HSPF2beats 93% · 10.8SHV18H2R20Ducted, up to 1.5 tonsbeats 55% · 8.2GSZC704810A*Ducted, 3.5 to 4.5 tons
SEER2beats 96% · 21.0VOM24H7R3P7Ducted, 2 tonsbeats 81% · 17.2GSZC704810A*Ducted, 3.5 to 4.5 tons
EER2beats 99% · 16.6EIN10H2V32(O)Non-ducted, up to 1.5 tonsbeats 92% · 12.5GSZB404810A*Ducted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hEIN18H2V32(O)Non-ducted, up to 1.5 tonsbeats 41% · 30,600 Btu/hGSZC706010A*Ducted, 3.5 to 4.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter