Innovair vs JANITROL heat pumps
Measured against models of the same size and duct type, Innovair scores higher on 5 of the 6 ratings. Innovair has 132 outdoor models, JANITROL has 6 outdoor models. JANITROL has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Innovair
- JANITROL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Innovair | JANITROL |
|---|---|---|
| Efficiency index | 59% (higher)median — · 8th ranked | 58% (higher)median — |
| COP at 5°F | 60% (higher)median 2.00 · 9th ranked | 52% (higher)median 2.00 |
| Capacity retention at 5°F | 61% (higher)median 78% · 6th ranked | 29% (higher)median 50% |
| HSPF2 | 61% (higher)median 9.5 · 7th ranked | 55% (higher)median 8.2 |
| SEER2 | 59% (higher)median 20.0 · 8th ranked | 51% (higher)median 15.6 |
| EER2 | 51%median 11.5 · 16th ranked | 91%median 12.5 |
| Heating capacity at 5°F | 60% (higher)median 19,200 Btu/h · 8th ranked | 32% (higher)median 26,300 Btu/h |
| Outdoor models | 132 | 6 |
| AHRI certifications | 945 | 29 |
Share of models meeting each standard
| Standard | Innovair | JANITROL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 80.3%106 models | 50%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 78.8%104 models | 50%3 models |
| CEE Advanced Tier (Split ASHP) | 1.5%2 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 77.3%102 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 1.5%2 models | 0%0 models |
| ENERGY STAR Cold Climate | 67.4%89 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Innovair
- JANITROL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Innovair | JANITROL |
|---|---|---|
| Ducted, up to 1.5 tons | 20 · index 70% | None |
| Ducted, 2 tons | 13 · index 61% | None |
| Ducted, 2.5 to 3 tons | 28 · index 62% | None |
| Ducted, 3.5 to 4.5 tons | 24 · index 65% | 4 · index 56% |
| Ducted, 5 tons and up | 4 · index 63% | 2 · index 63% |
| Non-ducted, up to 1.5 tons | 48 · index 55% | None |
| Non-ducted, 2 tons | 9 · index 54% | None |
| Non-ducted, 2.5 to 3 tons | 20 · index 55% | None |
| Non-ducted, 3.5 to 4.5 tons | 12 · index 53% | None |
| Non-ducted, 5 tons and up | 2 · index 59% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | InnovairCold-climate score, best model | JANITROLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)SHV18H2BAwith ducted air handler SWV18BDA16 of 19 models qualify · AHRI 216027612 | No models in this size class |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)MOS24H2BH0Awith ducted air handler MDH24H2MHWA11 of 14 models qualify · AHRI 215725473 | No models in this size class |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)MOS36H2BH0Awith ducted air handler MDH36H2MHWA22 of 28 models qualify · AHRI 215735335 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B21 of 24 models qualify · AHRI 215725526 | None on this board (0 of 4 models qualify) |
| Ducted, 5 tons and up | 58.6(50 is the typical model of its size class)PXV60H2A1 of 4 models qualify · AHRI 217753792 | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB39 of 48 models qualify · AHRI 215725442 | No models in this size class |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)MOS24H2BH0Awith ductless indoor unit MCS24H2BHRA9 of 9 models qualify · AHRI 217230001 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)MOS36H2BH0Awith ductless indoor unit MFC36H2BHRA16 of 20 models qualify · AHRI 217230015 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 73.7(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B11 of 12 models qualify · AHRI 215725527 | No models in this size class |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | No models in this size class |
All-around best
| Size and duct type | InnovairAll-around score, best model | JANITROLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)MOS09H2BH0Awith ducted air handler MDL09H2MHWA17 of 19 models have all five ratings · AHRI 215725467 | No models in this size class |
| Ducted, 2 tons | 79.5(50 is the typical model of its size class)GOV36H2BAwith ducted air handler GAV24B2A11 of 13 models have all five ratings · AHRI 215318726 | No models in this size class |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B25 of 29 models have all five ratings · AHRI 215725523 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)MOM48H2BM6AAlso listed as MOM48H2BM6B21 of 24 models have all five ratings · AHRI 215725499 | 64.0(50 is the typical model of its size class)GLZT7CA4810A*with ducted air handler AMVT60DP1300A4 of 4 models have all five ratings · AHRI 216369309 |
| Ducted, 5 tons and up | 65.9(50 is the typical model of its size class) (higher)MOS60H2BM0Awith ducted air handler MDH60H2MHWA4 of 4 models have all five ratings · AHRI 215725466 | 63.5(50 is the typical model of its size class)GLZS5BA6010A*with ducted air handler AMST60DU1300A2 of 2 models have all five ratings · AHRI 216369273 |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB48 of 48 models have all five ratings · AHRI 215725442 | No models in this size class |
| Non-ducted, 2 tons | 87.8(50 is the typical model of its size class)MOS24H2BM0Awith ductless indoor unit MHW24H2BHRB9 of 9 models have all five ratings · AHRI 215725441 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B20 of 20 models have all five ratings · AHRI 215725522 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 75.5(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B12 of 12 models have all five ratings · AHRI 215725525 | No models in this size class |
| Non-ducted, 5 tons and up | 59.0(50 is the typical model of its size class)MOM60H2BM6AAlso listed as MOM60H2BM6B2 of 2 models have all five ratings · AHRI 215835696 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Innovair | JANITROL |
|---|---|---|
| COP at 5°F | beats 100% · 2.53QOS18H2XE5ANon-ducted, up to 1.5 tons | beats 54% · 2.00GLZS4BA6010A*Ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 100% · 133%QOS09H2BH0ADucted, up to 1.5 tons | beats 32% · 57%GLZT7CA6010A*Ducted, 3.5 to 4.5 tons |
| HSPF2 | beats 99% · 14.8MOS06H2BH0ANon-ducted, up to 1.5 tons | beats 66% · 8.2GLZS5BA6010A*Ducted, 5 tons and up |
| SEER2 | beats 98% · 21.0POM27H2BM3ADucted, 2.5 to 3 tons | beats 67% · 17.2GLZT7CA4810A*Ducted, 3.5 to 4.5 tons |
| EER2 | beats 99% · 18.0MOS06H2BH0ANon-ducted, up to 1.5 tons | beats 94% · 12.5GLZS4BA6010A*Ducted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 98% · 19,600 Btu/hSHV18H2BADucted, up to 1.5 tons | beats 55% · 31,000 Btu/hGLZT7CA6010A*Ducted, 5 tons and up |