Skip to content

LBG Products vs LPS Legacy: heat pump ratings compared

Against heat pumps of the same size and type, a typical LBG Products model beats 54% and a typical LPS Legacy model 53%. LBG Products rates slightly higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

LBG Products

54%

of similar heat pumps beaten by its typical model

About average

60 models listed

LPS Legacy

53%

of similar heat pumps beaten by its typical model

About average

58 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FLBG Products: Beats 47%LPS Legacy: Beats 52%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FLBG Products: Beats 61%LPS Legacy: Beats 50%
  • Winter-long heating efficiencyHSPF2LBG Products: Beats 66%LPS Legacy: Beats 62%
  • Summer-long cooling efficiencySEER2LBG Products: Beats 55%LPS Legacy: Beats 55%
  • Hot-day cooling efficiencyEER2LBG Products: Beats 43%LPS Legacy: Beats 42%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    LBG Products
    67%
    LPS Legacy
    59%
  • Xcel CC

    LBG Products
    58%
    LPS Legacy
    40%
  • CEE Advanced

    LBG Products
    2%
    LPS Legacy
    3%
  • ENERGY STAR CC

    LBG Products
    50%
    LPS Legacy
    43%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

LBG Products

  1. 1LMHB27DOLBG Products2.5 tons · 28,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    75.4score / 100Heating 65 · Cooling 86
  2. 2LMUHB27DOLBG Products2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 66.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    74.7score / 100Heating 67 · Cooling 83
  3. 3LMUHB36DOLBG Products3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 64.0Meets none of the standards tracked here
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Good
    71.4score / 100Heating 64 · Cooling 79

LPS Legacy

  1. 1DLCMHBH30DAKLPS Legacy2.5 tons · 30,000 Btu/h · DuctedNot a cold-climate pick: keeps 60% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    60% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    72.1score / 100Heating 54 · Cooling 90
  2. 2DLCMHBH36DAKLPS Legacy3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 64.0Meets none of the standards tracked here
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Good
    71.4score / 100Heating 64 · Cooling 79
  3. 3DLCMRBH36DAKLPS Legacy3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 64% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.68 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    56.5score / 100Heating 44 · Cooling 69

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter