Skip to content

Lennox vs Trane: heat pump ratings compared

Against heat pumps of the same size and type, a typical Lennox model beats 54% and a typical Trane model 53%. Lennox rates slightly higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Lennox

54%

of similar heat pumps beaten by its typical model

About average

375 models listed

Trane

53%

of similar heat pumps beaten by its typical model

About average

309 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FLennox: Beats 56%Trane: Beats 70%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FLennox: Beats 49%Trane: Beats 44%
  • Winter-long heating efficiencyHSPF2Lennox: Beats 46%Trane: Beats 35%
  • Summer-long cooling efficiencySEER2Lennox: Beats 47%Trane: Beats 37%
  • Hot-day cooling efficiencyEER2Lennox: Beats 54%Trane: Beats 65%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Lennox
    40%
    Trane
    31%
  • Xcel CC

    Lennox
    33%
    Trane
    22%
  • CEE Advanced

    Lennox
    1%
    Trane
    0%
  • ENERGY STAR CC

    Lennox
    17%
    Trane
    9%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Lennox

  1. 1A-VMH36QV-1ALennox (sold as Comfort-Aire)3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 79.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.4 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    83.7score / 100Heating 80 · Cooling 88
  2. 2SL25XPV-036-230A**with indoor coil CRX35-50/60C-**-*+TDR and furnace SLP99DF090XV36CLennox3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 65.3Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.86 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.4 (HSPF2)
    Great
    Cooling efficiency
    22.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.5 (EER2)
    Top 10%
    82.7score / 100Heating 65 · Cooling 100
  3. 34SHP22LX136P-**Awith indoor coil C(A,C,D,E)48C34+TDR and furnace A97US2V080C16XLennox (sold as Armstrong Air)3 tons · 33,400 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    66% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.69 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    80.9score / 100Heating 72 · Cooling 90

Trane

  1. 14TWV0X36A1with indoor coil D(A,C,E)48C34+TDR and furnace S9V2C080U5PSC+RPTrane3 tons · 33,400 Btu/h · DuctedCold-climate pick, score 82.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.59 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    19.5 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    85.1score / 100Heating 82 · Cooling 88
  2. 24TWV8X36A1with indoor coil D(A,C,E)48C34+TDR and furnace S9V2C080U5PSC+RPTrane3 tons · 33,200 Btu/h · DuctedCold-climate pick, score 72.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.22 (COP at 5°F)
    Great
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    77.7score / 100Heating 72 · Cooling 83
  3. 34A6V0X36A1with indoor coil 4PX*CU48BS3 and furnace S9V2C100U4PSB+RPTrane (sold as American Standard)3 tons · 35,600 Btu/h · DuctedCold-climate pick, score 54.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    63% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.94 (COP at 5°F)
    Good
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    12.7 (EER2)
    Top 10%
    75.5score / 100Heating 54 · Cooling 97

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter