Skip to content

LG vs Nortek Global HVAC heat pumps

Measured against models of the same size and duct type, LG scores higher on 5 of the 6 ratings. LG has 78 outdoor models, Nortek Global HVAC has 75 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
LG and Nortek Global HVAC on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, LG scores higher on 5 of the 6 ratings.
  • LG
  • Nortek Global HVAC
  • Other ranked manufacturers
LGNortek G…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingLGNortek Global HVAC
Efficiency index65% (higher)median — · 2nd ranked51% (higher)median — · 20th ranked
COP at 5°F59% (higher)median 2.06 · 7th ranked44% (higher)median 1.85 · 23rd ranked
Capacity retention at 5°F64%median 80% · 5th ranked64%median 80% · 4th ranked
HSPF270% (higher)median 9.5 · 3rd ranked38% (higher)median 8.2 · 22nd ranked
SEER263% (higher)median 20.2 · 6th ranked39% (higher)median 16.5 · 22nd ranked
EER269% (higher)median 12.5 · 1st ranked46% (higher)median 11.0 · 21st ranked
Heating capacity at 5°F67% (higher)median 19,900 Btu/h · 3rd ranked56% (higher)median 14,500 Btu/h · 10th ranked
Outdoor models7875
AHRI certifications175280

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardLGNortek Global HVAC
CEE 2025 Tier 1 (Split ASHP)74.4%58 models38.7%29 models
CEE 2026 Tier 1 (Split ASHP)74.4%58 models38.7%29 models
CEE Advanced Tier (Split ASHP)9%7 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)67.9%53 models41.3%31 models
DOE Cold Climate Heat Pump Challenge9%7 models0%0 models
ENERGY STAR Cold Climate44.9%35 models29.3%22 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • LG
  • Nortek Global HVAC
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeLGNortek Global HVAC
Ducted, up to 1.5 tons11 · index 57%10 · index 47%
Ducted, 2 tons7 · index 71%7 · index 52%
Ducted, 2.5–3 tons9 · index 80%20 · index 55%
Ducted, 3.5–4.5 tons15 · index 79%13 · index 58%
Ducted, 5 tons and up3 · index 72%None
Non-ducted, up to 1.5 tons35 · index 54%23 · index 47%
Non-ducted, 2 tons10 · index 61%7 · index 53%
Non-ducted, 2.5–3 tons10 · index 69%10 · index 56%
Non-ducted, 3.5–4.5 tons11 · index 70%1 · index 45%
Non-ducted, 5 tons and up3 · index 55%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeLGCold-climate score, best modelNortek Global HVACCold-climate score, best model
Ducted, up to 1.5 tons78.7(50 is the typical model of its size class) (higher)LUU090HVwith ducted air handler LHN098HV18 of 11 models qualify · AHRI 21257884655.9(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models qualify · AHRI 207237540
Ducted, 2 tons92.9(50 is the typical model of its size class) (higher)ARUN024GSS45 of 7 models qualify · AHRI 1007056368.1(50 is the typical model of its size class)WHM24SZA21Swith ducted air handler D(A,C,E)24D44+TDR4 of 6 models qualify · AHRI 214640590
Ducted, 2.5–3 tons97.0(50 is the typical model of its size class) (higher)ARUN038GSS47 of 9 models qualify · AHRI 871793278.1(50 is the typical model of its size class)WHU36SZA21Swith ducted air handler WHU36DHA21S7 of 21 models qualify · AHRI 207237544
Ducted, 3.5–4.5 tons86.4(50 is the typical model of its size class) (higher)LMU480HHV12 of 15 models qualify · AHRI 20671700973.0(50 is the typical model of its size class)WHM60SZA21Swith ducted air handler D(A,C,E)60B44+TDR4 of 13 models qualify · AHRI 214640596
Ducted, 5 tons and up81.7(50 is the typical model of its size class)LMU601HV2 of 3 models qualify · AHRI 206717003No models in this size class
Non-ducted, up to 1.5 tons95.4(50 is the typical model of its size class) (higher)LAU090HYV3with ductless indoor unit LAN090HYV322 of 35 models qualify · AHRI 20482517778.4(50 is the typical model of its size class)WHU09SZA21Swith ductless indoor unit WHU09CTA21S17 of 23 models qualify · AHRI 207237535
Non-ducted, 2 tons92.9(50 is the typical model of its size class) (higher)ARUN024GSS47 of 10 models qualify · AHRI 1007056276.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-15 of 7 models qualify · AHRI 210276801
Non-ducted, 2.5–3 tons92.2(50 is the typical model of its size class) (higher)ARUN038GSS47 of 10 models qualify · AHRI 871793177.2(50 is the typical model of its size class)WHU36SZA21Swith ductless indoor unit WHU36CTA21S7 of 10 models qualify · AHRI 207237539
Non-ducted, 3.5–4.5 tons97.4(50 is the typical model of its size class) (higher)LMU421HHV8 of 11 models qualify · AHRI 20671700142.0(50 is the typical model of its size class)WHP42M5A21S1 of 1 models qualify · AHRI 208404161
Non-ducted, 5 tons and up71.5(50 is the typical model of its size class)ARUB060GSS43 of 3 models qualify · AHRI 10271659No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeLGAll-around score, best modelNortek Global HVACAll-around score, best model
Ducted, up to 1.5 tons64.8(50 is the typical model of its size class) (higher)LUU180HHVwith ducted air handler LVN181HV48 of 11 models have all five ratings · AHRI 20578877457.7(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models have all five ratings · AHRI 207237540
Ducted, 2 tons86.9(50 is the typical model of its size class) (higher)ARUN024GSS46 of 7 models have all five ratings · AHRI 1007056371.6(50 is the typical model of its size class)WHP24M3A21S6 of 7 models have all five ratings · AHRI 208404156
Ducted, 2.5–3 tons97.5(50 is the typical model of its size class) (higher)ARUN038GSS48 of 9 models have all five ratings · AHRI 871793278.6(50 is the typical model of its size class)WHP36M4A21S7 of 20 models have all five ratings · AHRI 208404158
Ducted, 3.5–4.5 tons89.8(50 is the typical model of its size class) (higher)LMU480HHV15 of 15 models have all five ratings · AHRI 20671700965.5(50 is the typical model of its size class)WHM48SZA21Swith ducted air handler DC61A44-245R4 of 13 models have all five ratings · AHRI 213886028
Ducted, 5 tons and up78.9(50 is the typical model of its size class)LMU601HV2 of 3 models have all five ratings · AHRI 206717003No models in this size class
Non-ducted, up to 1.5 tons95.3(50 is the typical model of its size class) (higher)LAU090HYV3with ductless indoor unit LAN090HYV331 of 35 models have all five ratings · AHRI 20482517785.4(50 is the typical model of its size class)WHZ09SZA21Swith ductless indoor unit WHZ09WMA21S19 of 24 models have all five ratings · AHRI 207337194
Non-ducted, 2 tons88.3(50 is the typical model of its size class) (higher)LAU240HYV3with ductless indoor unit LAN240HYV39 of 10 models have all five ratings · AHRI 20482518171.5(50 is the typical model of its size class)GXH24(7.0)FMK4DH-16 of 7 models have all five ratings · AHRI 210276801
Non-ducted, 2.5–3 tons87.4(50 is the typical model of its size class) (higher)LMU361HHV10 of 10 models have all five ratings · AHRI 20671700770.2(50 is the typical model of its size class)GXH42(12.3)FMK4DH-18 of 10 models have all five ratings · AHRI 210276799
Non-ducted, 3.5–4.5 tons92.1(50 is the typical model of its size class)LMU421HHV11 of 11 models have all five ratings · AHRI 206717001No models in this size class
Non-ducted, 5 tons and up61.0(50 is the typical model of its size class)LMU601HV3 of 3 models have all five ratings · AHRI 206717015No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingLGNortek Global HVAC
COP at 5°Fbeats 100% · 3.19ARUN038GSS4Non-ducted, 2.5–3 tonsbeats 96% · 2.28WHU36SZA21SNon-ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 100% · 114%ARUM036GSS5Non-ducted, 2.5–3 tonsbeats 99% · 113%WHP36M4A21SNon-ducted, 2.5–3 tons
HSPF2beats 99% · 9.5LMU601HVDucted, 5 tons and upbeats 83% · 9.5WHU36SZA21SDucted, 2.5–3 tons
SEER2beats 99% · 18.5LMU601HVDucted, 5 tons and upbeats 96% · 27.5WHZ09SZA21SNon-ducted, up to 1.5 tons
EER2beats 100% · 15.5ARUM036GSS5Non-ducted, 2.5–3 tonsbeats 93% · 15.5WHZ09SZA21SNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 48,000 Btu/hARUM036GSS5Non-ducted, 2.5–3 tonsbeats 92% · 18,000 Btu/hWHP18M2A21SNon-ducted, up to 1.5 tons

More comparisons