Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
MANUFLOW vs Wells heat pumps
Measured against models of the same size and duct type, Wells scores higher on 5 of the 6 ratings. MANUFLOW has 34 outdoor models, Wells has 35 outdoor models. MANUFLOW and Wells have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- MANUFLOW
- Wells
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | MANUFLOW | Wells |
|---|---|---|
| Efficiency index | 56%median — | 57%median — |
| COP at 5°F | 34%median 1.80 | 40%median 1.85 |
| Capacity retention at 5°F | 48%median 70% | 60%median 79% |
| HSPF2 | 28%median 8.6 | 70%median 9.5 |
| SEER2 | 39%median 19.8 | 65%median 20.2 |
| EER2 | 50%median 11.7 | 50%median 11.0 |
| Heating capacity at 5°F | 45%median 8,400 Btu/h | 59%median 23,000 Btu/h |
| Outdoor models | 34 | 35 |
| AHRI certifications | 34 | 70 |
Share of models meeting each standard
| Standard | MANUFLOW | Wells |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 35.3%12 models | 74.3%26 models |
| CEE 2026 Tier 1 (Split ASHP) | 35.3%12 models | 68.6%24 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 29.4%10 models | 60%21 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 60%21 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- MANUFLOW
- Wells
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | MANUFLOW | Wells |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index 59% |
| Ducted, 2 tons | None | 1 · index 53% |
| Ducted, 2.5–3 tons | None | 9 · index 62% |
| Ducted, 3.5–4.5 tons | None | 8 · index 58% |
| Ducted, 5 tons and up | None | 1 · index 57% |
| Non-ducted, up to 1.5 tons | 26 · index 55% | 11 · index 56% |
| Non-ducted, 2 tons | 6 · index 59% | 2 · index 49% |
| Non-ducted, 2.5–3 tons | 2 · index — | 7 · index 57% |
| Non-ducted, 3.5–4.5 tons | None | 4 · index 51% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | MANUFLOWCold-climate score, best model | WellsCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 52.0(50 is the typical model of its size class)WMMA-18HFMO2 of 2 models qualify · AHRI 213286761 |
| Ducted, 2 tons | No models in this size class | 66.5(50 is the typical model of its size class)WUCA-24HFMOwith ducted air handler WUA-24HFMAH1 of 1 models qualify · AHRI 213307899 |
| Ducted, 2.5–3 tons | No models in this size class | 80.4(50 is the typical model of its size class)WMCA-27HFMO7 of 9 models qualify · AHRI 213286779 |
| Ducted, 3.5–4.5 tons | No models in this size class | 74.9(50 is the typical model of its size class)WMCA-48HFMO5 of 8 models qualify · AHRI 213286782 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 75.7(50 is the typical model of its size class) (higher)AS-09UW3SXEDJ(O)with ductless indoor unit AS-09UW3SXEDJ(I)9 of 26 models qualify · AHRI 202021915 | 74.8(50 is the typical model of its size class)WSA-09HFMOwith ductless indoor unit WSA-09HFMI7 of 11 models qualify · AHRI 214421469 |
| Non-ducted, 2 tons | 64.0(50 is the typical model of its size class) (higher)AST-24UW3SDBDJ01(O)with ductless indoor unit AST-24UW3SDBDJ01(I)1 of 6 models qualify · AHRI 203446798 | 61.1(50 is the typical model of its size class)WSA-24HFMOwith ductless indoor unit WSA-24HFMI1 of 2 models qualify · AHRI 214421472 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 87.0(50 is the typical model of its size class)WMCA-36HFMO4 of 7 models qualify · AHRI 213307896 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 80.5(50 is the typical model of its size class)WMCA-48HFMO2 of 4 models qualify · AHRI 213286781 |
All-around best
| Size and duct type | MANUFLOWAll-around score, best model | WellsAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 59.4(50 is the typical model of its size class)WMMA-18HFMO2 of 2 models have all five ratings · AHRI 213286761 |
| Ducted, 2 tons | No models in this size class | 65.8(50 is the typical model of its size class)WUCA-24HFMOwith ducted air handler WUA-24HFMAH1 of 1 models have all five ratings · AHRI 213307899 |
| Ducted, 2.5–3 tons | No models in this size class | 83.7(50 is the typical model of its size class)WMCA-36HFMO9 of 9 models have all five ratings · AHRI 213307897 |
| Ducted, 3.5–4.5 tons | No models in this size class | 82.0(50 is the typical model of its size class)WMCA-48HFMO8 of 8 models have all five ratings · AHRI 213286782 |
| Ducted, 5 tons and up | No models in this size class | 57.1(50 is the typical model of its size class)WSMA-60HFMOwith ducted air handler WSMA-60HFMD1 of 1 models have all five ratings · AHRI 214797744 |
| Non-ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)AS-09UW3SXEDJ(O)with ductless indoor unit AS-09UW3SXEDJ(I)12 of 26 models have all five ratings · AHRI 202021915 | 84.4(50 is the typical model of its size class)WSA-09HFMOwith ductless indoor unit WSA-09HFMI11 of 11 models have all five ratings · AHRI 214421469 |
| Non-ducted, 2 tons | 58.5(50 is the typical model of its size class)AST-24UW3SDBDJ01(O)with ductless indoor unit AST-24UW3SDBDJ01(I)1 of 6 models have all five ratings · AHRI 203446798 | 70.7(50 is the typical model of its size class) (higher)WSA-24HFMOwith ductless indoor unit WSA-24HFMI2 of 2 models have all five ratings · AHRI 214421472 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models have all five ratings) | 76.8(50 is the typical model of its size class)WMCA-36HFMO7 of 7 models have all five ratings · AHRI 213307896 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 73.8(50 is the typical model of its size class)WMCA-48HFMO4 of 4 models have all five ratings · AHRI 213286781 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | MANUFLOW | Wells |
|---|---|---|
| COP at 5°F | beats 81% · 2.13AST-24UW3SDBDJ01(O)Non-ducted, 2 tons | beats 83% · 2.16WSB-09HFBONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 73% · 89%AS-09UW3SXEDJ(O)Non-ducted, up to 1.5 tons | beats 96% · 101%WMCA-27HFMODucted, 2.5–3 tons |
| HSPF2 | beats 79% · 10.5AS-09UR3SXEDJ(O)Non-ducted, up to 1.5 tons | beats 97% · 10.9WMCA-36HFMONon-ducted, 2.5–3 tons |
| SEER2 | beats 96% · 27.5AS-09UR3SXEDJ(O)Non-ducted, up to 1.5 tons | beats 99% · 20.9WMCA-48HFMODucted, 3.5–4.5 tons |
| EER2 | beats 93% · 15.5AS-09UR3SXEDJ(O)Non-ducted, up to 1.5 tons | beats 95% · 15.8WSA-09HFMONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 83% · 13,770 Btu/hAST-18UW3SBBDJ00(O)Non-ducted, up to 1.5 tons | beats 96% · 20,000 Btu/hWMCA-18HFMONon-ducted, up to 1.5 tons |