Skip to content

Manuflow vs Wells heat pumps

Measured against models of the same size and duct type, Wells scores higher on 6 of the 6 ratings. Manuflow has 23 outdoor models, Wells has 37 outdoor models. Manuflow and Wells have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Manuflow and Wells on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Wells scores higher on 6 of the 6 ratings.
  • Manuflow
  • Wells
  • Other ranked manufacturers
ManuflowWells

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingManuflowWells
Efficiency index47%median —63%median —
COP at 5°F37%median 1.8064%median 2.10
Capacity retention at 5°F42%median 73%61%median 75%
HSPF256%median 10.074%median 10.0
SEER258%median 22.062%median 19.4
EER238%median 11.259%median 12.0
Heating capacity at 5°F51%median 13,200 Btu/h62%median 19,000 Btu/h
Outdoor models2337
AHRI certifications23121

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardManuflowWells
CEE 2025 Tier 1 (Split ASHP)82.6%19 models86.5%32 models
CEE 2026 Tier 1 (Split ASHP)82.6%19 models83.8%31 models
CEE Advanced Tier (Split ASHP)0%0 models2.7%1 models
Xcel Energy Colorado cold-climate ASHP (2025)78.3%18 models81.1%30 models
DOE Cold Climate Heat Pump Challenge0%0 models2.7%1 models
ENERGY STAR Cold Climate0%0 models83.8%31 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 6 groups where both have models
  • Manuflow
  • Wells
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeManuflowWells
Ducted, up to 1.5 tons2 · index 50%9 · index 80%
Ducted, 2 tons1 · index 56%5 · index 73%
Ducted, 2.5–3 tonsNone7 · index 67%
Ducted, 3.5–4.5 tonsNone7 · index 63%
Ducted, 5 tons and upNone1 · index 63%
Non-ducted, up to 1.5 tons12 · index 47%16 · index 58%
Non-ducted, 2 tons4 · index 44%4 · index 53%
Non-ducted, 2.5–3 tons3 · index 46%4 · index 54%
Non-ducted, 3.5–4.5 tons1 · index 42%3 · index 57%
Non-ducted, 5 tons and upNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeManuflowCold-climate score, best modelWellsCold-climate score, best model
Ducted, up to 1.5 tons54.1(50 is the typical model of its size class)TSDUC18HR2VIR45I*2 of 2 models qualify · AHRI 21676301493.5(50 is the typical model of its size class) (higher)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models qualify · AHRI 215864077
Ducted, 2 tons60.1(50 is the typical model of its size class)TSDUC24CD2VIR45I*1 of 1 models qualify · AHRI 21676301585.7(50 is the typical model of its size class) (higher)WOS-24PRE/230with ducted air handler WIDH-24MOC/2305 of 5 models qualify · AHRI 215864084
Ducted, 2.5–3 tonsNo models in this size class82.5(50 is the typical model of its size class)WOM-36HH5/2307 of 7 models qualify · AHRI 215864112
Ducted, 3.5–4.5 tonsNo models in this size class82.7(50 is the typical model of its size class)WOM-48HH6/2307 of 7 models qualify · AHRI 215864115
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons68.6(50 is the typical model of its size class)TFM2G18CHAIR454B9 of 12 models qualify · AHRI 21676300394.4(50 is the typical model of its size class) (higher)WOS-06PRE/230with ductless indoor unit WI1C-06MOC/23011 of 16 models qualify · AHRI 215864073
Non-ducted, 2 tons58.8(50 is the typical model of its size class)TSCAS24CD2VIR45I*with ductless indoor unit TSCAS24CD2VIR45I3 of 4 models qualify · AHRI 21676301289.4(50 is the typical model of its size class) (higher)WOS-24PRE/230with ductless indoor unit WI4C-24MOC/2304 of 4 models qualify · AHRI 215864072
Non-ducted, 2.5–3 tons57.5(50 is the typical model of its size class)TFM3G27CHAIR454B2 of 3 models qualify · AHRI 21676300472.6(50 is the typical model of its size class) (higher)WOM-36HH5/2304 of 4 models qualify · AHRI 215864113
Non-ducted, 3.5–4.5 tons31.2(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models qualify · AHRI 21676300669.9(50 is the typical model of its size class) (higher)WOM-60HH6/2303 of 3 models qualify · AHRI 215864119
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeManuflowAll-around score, best modelWellsAll-around score, best model
Ducted, up to 1.5 tons57.0(50 is the typical model of its size class)TSDUC18HR2VIR45I*2 of 2 models have all five ratings · AHRI 21676301495.0(50 is the typical model of its size class) (higher)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models have all five ratings · AHRI 215864077
Ducted, 2 tons55.8(50 is the typical model of its size class)TSDUC24CD2VIR45I*1 of 1 models have all five ratings · AHRI 21676301579.6(50 is the typical model of its size class) (higher)WDHP-2436T-Gwith ducted air handler WDAH-24MOC-G5 of 5 models have all five ratings · AHRI 217048501
Ducted, 2.5–3 tonsNo models in this size class83.6(50 is the typical model of its size class)WOM-36HH5/2307 of 7 models have all five ratings · AHRI 215864112
Ducted, 3.5–4.5 tonsNo models in this size class85.1(50 is the typical model of its size class)WOM-48RH6/2307 of 7 models have all five ratings · AHRI 215864100
Ducted, 5 tons and upNo models in this size class62.5(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864103
Non-ducted, up to 1.5 tons74.4(50 is the typical model of its size class)THH12E2S25NAR454Owith ductless indoor unit THH12E2S25NAR454I12 of 12 models have all five ratings · AHRI 21670786193.8(50 is the typical model of its size class) (higher)WOS-06PRE/230with ductless indoor unit WIHW-06MOC/23016 of 16 models have all five ratings · AHRI 215864044
Non-ducted, 2 tons56.5(50 is the typical model of its size class)TSCAS24CD2VIR45I*with ductless indoor unit TSCAS24CD2VIR45I4 of 4 models have all five ratings · AHRI 21676301274.3(50 is the typical model of its size class) (higher)WOS-24QUA/230with ductless indoor unit WIHW-24MOC/2304 of 4 models have all five ratings · AHRI 215864043
Non-ducted, 2.5–3 tons65.1(50 is the typical model of its size class)TFM3G27CHAIR454B3 of 3 models have all five ratings · AHRI 21676300466.3(50 is the typical model of its size class) (higher)WOM-36HH5/2304 of 4 models have all five ratings · AHRI 215864111
Non-ducted, 3.5–4.5 tons42.4(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models have all five ratings · AHRI 21676300662.6(50 is the typical model of its size class) (higher)WOM-60HH6/2303 of 3 models have all five ratings · AHRI 215864117
Non-ducted, 5 tons and upNo models in this size class32.5(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864102

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingManuflowWells
COP at 5°Fbeats 81% · 2.03TSHG36E2S19NAR45ONon-ducted, 2.5–3 tonsbeats 99% · 2.51WOS-12QUA/230Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 87% · 100%THH12E2S25NAR454ONon-ducted, up to 1.5 tonsbeats 98% · 126%WOS-09PRE/230Non-ducted, up to 1.5 tons
HSPF2beats 81% · 10.4TSCAS24CD2VIR45I*Non-ducted, 2 tonsbeats 99% · 11.0WOM-48HH6/230Ducted, 3.5–4.5 tons
SEER2beats 91% · 24.0TFM3G27CHAIR454BNon-ducted, 2.5–3 tonsbeats 96% · 20.4WOM-48RH6/230Ducted, 3.5–4.5 tons
EER2beats 83% · 14.0THH12E2S25NAR454ONon-ducted, up to 1.5 tonsbeats 99% · 14.4WOS-06PRE/230Ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 90% · 17,800 Btu/hTHH18E2S24NAR454ONon-ducted, up to 1.5 tonsbeats 97% · 39,000 Btu/hWDHP-36HHDucted, 2.5–3 tons

More comparisons