Skip to content

MITS AIR vs TK'S: heat pump ratings compared

Against heat pumps of the same size and type, a typical MITS AIR model beats 42% and a typical TK'S model 49%. TK'S rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

MITS AIR

42%

of similar heat pumps beaten by its typical model

Below average

16 models listed

TK'S

49%

of similar heat pumps beaten by its typical model

About average

16 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FMITS AIR: Beats 46%TK'S: Beats 36%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FMITS AIR: Beats 51%TK'S: Beats 32%
  • Winter-long heating efficiencyHSPF2MITS AIR: Beats 68%TK'S: Beats 56%
  • Summer-long cooling efficiencySEER2MITS AIR: Beats 39%TK'S: Beats 61%
  • Hot-day cooling efficiencyEER2MITS AIR: Beats 20%TK'S: Beats 46%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    MITS AIR
    31%
    TK'S
    63%
  • Xcel CC

    MITS AIR
    50%
    TK'S
    19%
  • CEE Advanced

    MITS AIR
    0%
    TK'S
    0%
  • ENERGY STAR CC

    MITS AIR
    56%
    TK'S
    0%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

MITS AIR

  1. 1MOX630-36HFN1-M3Xwith ducted air handler MVC-36HWFN1-MMITS AIR3 tons · 35,000 Btu/h · DuctedCold-climate pick, score 68.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    97% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.3 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Good
    68.6score / 100Heating 69 · Cooling 68
  2. 2MOE31U-36HFN1-Mwith ducted air handler MVC-36HWFN1-MMITS AIR3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 78.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.97 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    56.1score / 100Heating 75 · Cooling 37
  3. 3MOD30U-30HFN1-MR0(X)with ducted air handler MAC-36HWDN1-MN0MITS AIR2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 68.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.7 (HSPF2)
    Great
    Cooling efficiency
    15.5 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    52.5score / 100Heating 68 · Cooling 37

TK'S

  1. 1T3C-30HFN1*TK'S2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 57.6Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.83 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    71.7score / 100Heating 58 · Cooling 86
  2. 2T4C-36HFN1TK'SAlso listed as T4C-36HFN13 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 64% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.68 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    56.5score / 100Heating 44 · Cooling 69

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter