Skip to content

Mitsutomo vs THERMOCORE SYSTEMS heat pumps

Measured against models of the same size and duct type, Mitsutomo scores higher on 5 of the 6 ratings. Mitsutomo has 31 outdoor models, THERMOCORE SYSTEMS has 32 outdoor models. Mitsutomo and THERMOCORE SYSTEMS have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Mitsutomo and THERMOCORE SYSTEMS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Mitsutomo scores higher on 5 of the 6 ratings.
  • Mitsutomo
  • THERMOCORE SYSTEMS
  • Other ranked manufacturers
MitsutomoTHERMOCO…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMitsutomoTHERMOCORE SYSTEMS
Efficiency index60% (higher)median —54% (higher)median —
COP at 5°F49%median 1.9553%median 1.92
Capacity retention at 5°F73% (higher)median 88%38% (higher)median 66%
HSPF272% (higher)median 9.556% (higher)median 9.1
SEER260% (higher)median 20.058% (higher)median 20.9
EER250% (higher)median 11.748% (higher)median 10.9
Heating capacity at 5°F69% (higher)median 22,600 Btu/h41% (higher)median 17,200 Btu/h
Outdoor models3132
AHRI certifications7152

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMitsutomoTHERMOCORE SYSTEMS
CEE 2025 Tier 1 (Split ASHP)71%22 models59.4%19 models
CEE 2026 Tier 1 (Split ASHP)71%22 models50%16 models
CEE Advanced Tier (Split ASHP)3.2%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)67.7%21 models34.4%11 models
DOE Cold Climate Heat Pump Challenge3.2%1 models0%0 models
ENERGY STAR Cold Climate77.4%24 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • Mitsutomo
  • THERMOCORE SYSTEMS
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMitsutomoTHERMOCORE SYSTEMS
Ducted, up to 1.5 tons5 · index 65%None
Ducted, 2 tons2 · index 73%1 · index 74%
Ducted, 2.5 to 3 tons8 · index 66%2 · index 35%
Ducted, 3.5 to 4.5 tons6 · index 61%2 · index 58%
Ducted, 5 tons and upNone3 · index 51%
Non-ducted, up to 1.5 tons10 · index 56%13 · index 60%
Non-ducted, 2 tons2 · index 48%4 · index 60%
Non-ducted, 2.5 to 3 tons9 · index 59%7 · index 43%
Non-ducted, 3.5 to 4.5 tons4 · index 51%6 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMitsutomoCold-climate score, best modelTHERMOCORE SYSTEMSCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)HO-SZ09-AB-Qwith ducted air handler HD-UZ09-AB-Q5 of 5 models qualify · AHRI 214056566No models in this size class
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)HO-SZ24-AB-Qwith ducted air handler HD-UZ24-AB-Q2 of 2 models qualify · AHRI 21405656954.5(50 is the typical model of its size class)T423D-H224-C1 of 1 models qualify · AHRI 209549027
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class)HO-MT28-AC-Q7 of 8 models qualify · AHRI 213785766None on this board (0 of 2 models qualify)
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class)HO-SZ48-BB-Qwith ducted air handler HD-UZ48-BB-Q6 of 6 models qualify · AHRI 214056577None on this board (0 of 2 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tons83.1(50 is the typical model of its size class)HO-SZ06-AB-Qwith ductless indoor unit HJ-UZ06-AB-Q7 of 10 models qualify · AHRI 21130639789.8(50 is the typical model of its size class) (higher)T5HH27S-H206-Cwith ductless indoor unit T5HH27S-H206-E8 of 13 models qualify · AHRI 209549006
Non-ducted, 2 tons87.1(50 is the typical model of its size class) (higher)HO-SZ24-AB-Qwith ductless indoor unit HC-UZ24-AB-Q1 of 2 models qualify · AHRI 21405656585.5(50 is the typical model of its size class)T5HH22S-H224-Cwith ductless indoor unit T5HH22S-H224-E2 of 4 models qualify · AHRI 209549010
Non-ducted, 2.5 to 3 tons87.5(50 is the typical model of its size class)HO-MQ36-AC-Q6 of 9 models qualify · AHRI 213785768None on this board (0 of 7 models qualify)
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class) (higher)HO-MP48-AB-Q4 of 4 models qualify · AHRI 21130641056.2(50 is the typical model of its size class)T4C18S-H248-Cwith ductless indoor unit T3C18S-H248-ED1 of 6 models qualify · AHRI 209549023

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMitsutomoAll-around score, best modelTHERMOCORE SYSTEMSAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)HO-SZ09-AB-Qwith ducted air handler HD-UZ09-AB-Q5 of 5 models have all five ratings · AHRI 214056566No models in this size class
Ducted, 2 tons80.2(50 is the typical model of its size class) (higher)HO-SZ24-AB-Qwith ducted air handler HD-UZ24-AB-Q2 of 2 models have all five ratings · AHRI 21405656974.4(50 is the typical model of its size class)T423D-H224-C1 of 1 models have all five ratings · AHRI 209549027
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)HO-MQ36-AC-Q8 of 8 models have all five ratings · AHRI 21378576956.5(50 is the typical model of its size class)T424D-H236-C2 of 2 models have all five ratings · AHRI 209549030
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)HO-MP48-AB-Q6 of 6 models have all five ratings · AHRI 21130641163.5(50 is the typical model of its size class)T425D-H248-C2 of 2 models have all five ratings · AHRI 209549033
Ducted, 5 tons and upNo models in this size class57.2(50 is the typical model of its size class)T4C18S-H260-C-2with ducted air handler T3C18S-H260-EDT3 of 3 models have all five ratings · AHRI 209549019
Non-ducted, up to 1.5 tons85.0(50 is the typical model of its size class)HO-SZ09-AB-Qwith ductless indoor unit HW-SZ09-AB-Q10 of 10 models have all five ratings · AHRI 21130639392.3(50 is the typical model of its size class) (higher)T5HH27S-H206-Cwith ductless indoor unit T5HH27S-H206-E13 of 13 models have all five ratings · AHRI 209549006
Non-ducted, 2 tons71.9(50 is the typical model of its size class)HO-SZ24-AB-Qwith ductless indoor unit HW-SZ24-AB-Q2 of 2 models have all five ratings · AHRI 21130639684.9(50 is the typical model of its size class) (higher)T5HH22S-H224-Cwith ductless indoor unit T5HH22S-H224-E4 of 4 models have all five ratings · AHRI 209549010
Non-ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class) (higher)HO-MQ36-AC-Q9 of 9 models have all five ratings · AHRI 21378576861.0(50 is the typical model of its size class)T424D-H236-C5 of 7 models have all five ratings · AHRI 209549029
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class) (higher)HO-MP48-AB-Q4 of 4 models have all five ratings · AHRI 21130641056.0(50 is the typical model of its size class)T425D-H248-C4 of 6 models have all five ratings · AHRI 209549032

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMitsutomoTHERMOCORE SYSTEMS
COP at 5°Fbeats 87% · 2.01RO-SZ36-AB-QAlso listed as RO-SZ36-AC-QNon-ducted, 2.5 to 3 tonsbeats 96% · 2.38T424S-H218-CNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 101%HO-MT28-AC-QDucted, 2.5 to 3 tonsbeats 93% · 107%T5HH27S-H206-CNon-ducted, up to 1.5 tons
HSPF2beats 99% · 10.3HO-SZ48-BB-QDucted, 3.5 to 4.5 tonsbeats 99% · 13.6T5HH27S-H206-CNon-ducted, up to 1.5 tons
SEER2beats 99% · 20.9HO-MP48-AB-QDucted, 3.5 to 4.5 tonsbeats 99% · 24.6T423D-H224-CNon-ducted, 2 tons
EER2beats 95% · 15.8HO-SZ09-AB-QNon-ducted, up to 1.5 tonsbeats 98% · 16.2T5HH28S-H209-CNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hHW-SZ60-BB-QNon-ducted, 3.5 to 4.5 tonsbeats 92% · 18,000 Btu/hT5HH22S-H218-CNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Mitsutomo vs THERMOCORE SYSTEMS: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Mitsutomo (median, middle 50%)
  • THERMOCORE SYSTEMS (median, middle 50%)
Heating capacity, % of its 47°F maximum72%59%COP at maximum capacity1.911.98

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
Mitsutomo: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsutomo, 47°F30100%100%100%100%100%
Mitsutomo, 17°F3070%75%80%85%93%
Mitsutomo, 5°F3057%65%72%81%83%
Mitsutomo: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsutomo, 47°F302.642.792.993.213.45
Mitsutomo, 17°F301.92.052.152.232.34
Mitsutomo, 5°F301.81.841.9122.04
THERMOCORE SYSTEMS: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
THERMOCORE SYSTEMS, 47°F22100%100%100%100%100%
THERMOCORE SYSTEMS, 17°F2262%66%71%75%79%
THERMOCORE SYSTEMS, 5°F2255%57%59%64%69%
THERMOCORE SYSTEMS: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
THERMOCORE SYSTEMS, 47°F222.742.93.053.23.55
THERMOCORE SYSTEMS, 17°F221.982.062.182.382.49
THERMOCORE SYSTEMS, 5°F221.811.91.982.112.21

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter