Both views use the same certified data. This device remembers your choice.
Mitsutomo vs THERMOCORE SYSTEMS heat pumps
Measured against models of the same size and duct type, Mitsutomo and THERMOCORE SYSTEMS split the 6 ratings 3 to 3. Mitsutomo has 57 outdoor models, THERMOCORE SYSTEMS has 17 outdoor models. Mitsutomo and THERMOCORE SYSTEMS have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Mitsutomo
- THERMOCORE SYSTEMS
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Mitsutomo | THERMOCORE SYSTEMS |
|---|---|---|
| Efficiency index | 59%median — | 62%median — |
| COP at 5°F | 61%median 2.00 | 62%median 2.00 |
| Capacity retention at 5°F | 59% (higher)median 79% | 56% (higher)median 81% |
| HSPF2 | 70% (higher)median 9.7 | 69% (higher)median 10.1 |
| SEER2 | 57%median 19.0 | 66%median 21.4 |
| EER2 | 52%median 11.7 | 58%median 12.5 |
| Heating capacity at 5°F | 63% (higher)median 21,600 Btu/h | 62% (higher)median 19,700 Btu/h |
| Outdoor models | 57 | 17 |
| AHRI certifications | 166 | 35 |
Share of models meeting each standard
| Standard | Mitsutomo | THERMOCORE SYSTEMS |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 82.5%47 models | 100%17 models |
| CEE 2026 Tier 1 (Split ASHP) | 78.9%45 models | 94.1%16 models |
| CEE Advanced Tier (Split ASHP) | 3.5%2 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75.4%43 models | 70.6%12 models |
| DOE Cold Climate Heat Pump Challenge | 3.5%2 models | 0%0 models |
| ENERGY STAR Cold Climate | 77.2%44 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Mitsutomo
- THERMOCORE SYSTEMS
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Mitsutomo | THERMOCORE SYSTEMS |
|---|---|---|
| Ducted, up to 1.5 tons | 11 · index 77% | 1 · index 78% |
| Ducted, 2 tons | 5 · index 69% | 1 · index 65% |
| Ducted, 2.5 to 3 tons | 14 · index 62% | 3 · index 77% |
| Ducted, 3.5 to 4.5 tons | 12 · index 66% | 2 · index 70% |
| Ducted, 5 tons and up | 2 · index 65% | 1 · index 66% |
| Non-ducted, up to 1.5 tons | 19 · index 53% | 6 · index 65% |
| Non-ducted, 2 tons | 5 · index 50% | 2 · index 56% |
| Non-ducted, 2.5 to 3 tons | 9 · index 50% | 6 · index 59% |
| Non-ducted, 3.5 to 4.5 tons | 7 · index 42% | 3 · index 38% |
| Non-ducted, 5 tons and up | 1 · index 27% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | MitsutomoCold-climate score, best model | THERMOCORE SYSTEMSCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q10 of 11 models qualify · AHRI 217162571 | 71.3(50 is the typical model of its size class)T7HH25D-H224-C1 of 1 models qualify · AHRI 218003246 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class) (higher)HO-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models qualify · AHRI 217162578 | 48.1(50 is the typical model of its size class)T725D-H236-C1 of 1 models qualify · AHRI 218003240 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class) (higher)HO-SG36-LA-Qwith ducted air handler HD-UG36LA-Q10 of 14 models qualify · AHRI 217162598 | 82.7(50 is the typical model of its size class)T7HH25Q-H248-C3 of 3 models qualify · AHRI 218003252 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class) (higher)HO-MS48-LA-Q12 of 12 models qualify · AHRI 217162519 | 81.2(50 is the typical model of its size class)T7HH22X-H272-C2 of 2 models qualify · AHRI 218003255 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 94.9(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ductless indoor unit HJ-UZ06-LA-Q12 of 19 models qualify · AHRI 217162582 | 75.2(50 is the typical model of its size class)T7HH21S-H218-Cwith ductless indoor unit T7HH21S-H218-E3 of 6 models qualify · AHRI 218003230 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class) (higher)HO-SZ24-LA-Qwith ductless indoor unit HC-UZ24-LA-Q5 of 5 models qualify · AHRI 217162570 | 89.6(50 is the typical model of its size class)T7HH21S-H224-Cwith ductless indoor unit T7HH21S-H224-E2 of 2 models qualify · AHRI 218003231 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class) (higher)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q7 of 9 models qualify · AHRI 217162601 | 78.3(50 is the typical model of its size class)T7HH25Q-H248-C5 of 6 models qualify · AHRI 218003253 |
| Non-ducted, 3.5 to 4.5 tons | 70.3(50 is the typical model of its size class) (higher)HO-MS60-LA-Q6 of 7 models qualify · AHRI 217162523 | 66.5(50 is the typical model of its size class)T7HH22X-H272-C2 of 3 models qualify · AHRI 218003256 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | MitsutomoAll-around score, best model | THERMOCORE SYSTEMSAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 95.1(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q11 of 11 models have all five ratings · AHRI 217162571 | 77.9(50 is the typical model of its size class)T7HH25D-H224-C1 of 1 models have all five ratings · AHRI 218003246 |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class) (higher)RU-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models have all five ratings · AHRI 217162558 | 64.6(50 is the typical model of its size class)T725D-H236-C1 of 1 models have all five ratings · AHRI 218003240 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class)HO-MP36-LA-Q14 of 14 models have all five ratings · AHRI 217162516 | 83.9(50 is the typical model of its size class)T7HH25Q-H248-C3 of 3 models have all five ratings · AHRI 218003252 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)RO-MS48-LA-Q12 of 12 models have all five ratings · AHRI 217162504 | 82.5(50 is the typical model of its size class)T7HH22X-H272-C2 of 2 models have all five ratings · AHRI 218003255 |
| Ducted, 5 tons and up | 65.9(50 is the typical model of its size class)RU-SG60-LA-Qwith ducted air handler HD-UG60AL-Q2 of 2 models have all five ratings · AHRI 217162592 | 65.9(50 is the typical model of its size class)T7C20S-H260-Cwith ducted air handler T7C20S-H260-EDT1 of 1 models have all five ratings · AHRI 218003237 |
| Non-ducted, up to 1.5 tons | 94.5(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ductless indoor unit HW-UZ06-LA-Q19 of 19 models have all five ratings · AHRI 217162538 | 83.1(50 is the typical model of its size class)T7HH25D-H224-C6 of 6 models have all five ratings · AHRI 218003245 |
| Non-ducted, 2 tons | 75.9(50 is the typical model of its size class)RU-SZ24-LA-Qwith ductless indoor unit HW-UZ24-LA-Q5 of 5 models have all five ratings · AHRI 217162547 | 78.3(50 is the typical model of its size class) (higher)T7HH21S-H224-Cwith ductless indoor unit T7HH21S-H224-E2 of 2 models have all five ratings · AHRI 218003231 |
| Non-ducted, 2.5 to 3 tons | 67.1(50 is the typical model of its size class)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q9 of 9 models have all five ratings · AHRI 217162601 | 78.8(50 is the typical model of its size class) (higher)T7HH25Q-H248-C6 of 6 models have all five ratings · AHRI 218003251 |
| Non-ducted, 3.5 to 4.5 tons | 62.6(50 is the typical model of its size class)HO-MS60-LA-Q7 of 7 models have all five ratings · AHRI 217162521 | 63.6(50 is the typical model of its size class) (higher)T7HH22X-H272-C3 of 3 models have all five ratings · AHRI 218003254 |
| Non-ducted, 5 tons and up | 32.9(50 is the typical model of its size class)RO-MS60-LA-Q1 of 1 models have all five ratings · AHRI 217162506 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Mitsutomo | THERMOCORE SYSTEMS |
|---|---|---|
| COP at 5°F | beats 99% · 2.51RU-SZ12-LA-QNon-ducted, up to 1.5 tons | beats 95% · 2.34T7HH21S-H224-CNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 98% · 126%HO-SZ09-LA-QNon-ducted, up to 1.5 tons | beats 94% · 106%T7HH25Q-H248-CDucted, 2.5 to 3 tons |
| HSPF2 | beats 99% · 11.0HO-MS48-LA-QDucted, 3.5 to 4.5 tons | beats 98% · 13.5T7HH21S-H224-CNon-ducted, 2 tons |
| SEER2 | beats 96% · 20.4RO-MS48-LA-QDucted, 3.5 to 4.5 tons | beats 97% · 25.0T725D-H236-CNon-ducted, 2.5 to 3 tons |
| EER2 | beats 99% · 14.4HO-SZ06-LA-QDucted, up to 1.5 tons | beats 92% · 15.0T7HH25D-H224-CNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 98% · 39,500 Btu/hHO-SG36-LA-QNon-ducted, 2.5 to 3 tons | beats 97% · 19,000 Btu/hT7HH25D-H224-CNon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Mitsutomo (median, middle 50%)
- THERMOCORE SYSTEMS (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Mitsutomo, 47°F | 57 | 100% | 100% | 100% | 100% | 100% |
| Mitsutomo, 17°F | 57 | 63% | 67% | 72% | 80% | 85% |
| Mitsutomo, 5°F | 57 | 56% | 62% | 69% | 80% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Mitsutomo, 47°F | 57 | 2.86 | 3.09 | 3.23 | 3.46 | 3.61 |
| Mitsutomo, 17°F | 57 | 2.07 | 2.19 | 2.3 | 2.45 | 2.6 |
| Mitsutomo, 5°F | 57 | 1.85 | 1.97 | 2 | 2.12 | 2.26 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| THERMOCORE SYSTEMS, 47°F | 17 | 100% | 100% | 100% | 100% | 100% |
| THERMOCORE SYSTEMS, 17°F | 17 | 69% | 73% | 77% | 82% | 85% |
| THERMOCORE SYSTEMS, 5°F | 17 | 61% | 63% | 66% | 79% | 86% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| THERMOCORE SYSTEMS, 47°F | 17 | 2.88 | 3.09 | 3.19 | 3.44 | 3.52 |
| THERMOCORE SYSTEMS, 17°F | 17 | 2 | 2.12 | 2.35 | 2.45 | 2.62 |
| THERMOCORE SYSTEMS, 5°F | 17 | 1.9 | 2 | 2 | 2.15 | 2.24 |
Source: NEEP ccASHP list · as of