Skip to content

Mitsutomo vs THERMOCORE SYSTEMS heat pumps

Measured against models of the same size and duct type, Mitsutomo scores higher on 3 of the 6 ratings. Mitsutomo has 56 outdoor models, THERMOCORE SYSTEMS has 17 outdoor models. Mitsutomo and THERMOCORE SYSTEMS have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Mitsutomo and THERMOCORE SYSTEMS on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Mitsutomo scores higher on 3 of the 6 ratings.
  • Mitsutomo
  • THERMOCORE SYSTEMS
  • Other ranked manufacturers
MitsutomoTHERMOCO…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMitsutomoTHERMOCORE SYSTEMS
Efficiency index58%median —61%median —
COP at 5°F61%median 2.0061%median 2.00
Capacity retention at 5°F58% (higher)median 78%55% (higher)median 81%
HSPF269% (higher)median 9.768% (higher)median 10.1
SEER257%median 18.965%median 21.4
EER251%median 11.757%median 12.5
Heating capacity at 5°F62% (higher)median 21,100 Btu/h61% (higher)median 19,700 Btu/h
Outdoor models5617
AHRI certifications16535

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMitsutomoTHERMOCORE SYSTEMS
CEE 2025 Tier 1 (Split ASHP)82.1%46 models100%17 models
CEE 2026 Tier 1 (Split ASHP)78.6%44 models94.1%16 models
CEE Advanced Tier (Split ASHP)3.6%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)75%42 models70.6%12 models
DOE Cold Climate Heat Pump Challenge3.6%2 models0%0 models
ENERGY STAR Cold Climate76.8%43 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 9 groups where both have models
  • Mitsutomo
  • THERMOCORE SYSTEMS
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMitsutomoTHERMOCORE SYSTEMS
Ducted, up to 1.5 tons11 · index 76%1 · index 77%
Ducted, 2 tons5 · index 69%1 · index 65%
Ducted, 2.5–3 tons14 · index 62%3 · index 77%
Ducted, 3.5–4.5 tons12 · index 66%2 · index 69%
Ducted, 5 tons and up2 · index 64%1 · index 65%
Non-ducted, up to 1.5 tons19 · index 51%6 · index 64%
Non-ducted, 2 tons5 · index 48%2 · index 55%
Non-ducted, 2.5–3 tons8 · index 49%6 · index 58%
Non-ducted, 3.5–4.5 tons7 · index 42%3 · index 38%
Non-ducted, 5 tons and up1 · index 27%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMitsutomoCold-climate score, best modelTHERMOCORE SYSTEMSCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q10 of 11 models qualify · AHRI 21716257170.8(50 is the typical model of its size class)T7HH25D-H224-C1 of 1 models qualify · AHRI 218003246
Ducted, 2 tons85.7(50 is the typical model of its size class) (higher)HO-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models qualify · AHRI 21716257848.6(50 is the typical model of its size class)T725D-H236-C1 of 1 models qualify · AHRI 218003240
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class) (higher)HO-SG36-LA-Qwith ducted air handler HD-UG36LA-Q10 of 14 models qualify · AHRI 21716259882.5(50 is the typical model of its size class)T7HH25Q-H248-C3 of 3 models qualify · AHRI 218003252
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class) (higher)HO-MS48-LA-Q12 of 12 models qualify · AHRI 21716251981.2(50 is the typical model of its size class)T7HH22X-H272-C2 of 2 models qualify · AHRI 218003255
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons94.4(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ductless indoor unit HJ-UZ06-LA-Q12 of 19 models qualify · AHRI 21716258273.8(50 is the typical model of its size class)T7HH21S-H218-Cwith ductless indoor unit T7HH21S-H218-E3 of 6 models qualify · AHRI 218003230
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)HO-SZ24-LA-Qwith ductless indoor unit HC-UZ24-LA-Q5 of 5 models qualify · AHRI 21716257088.4(50 is the typical model of its size class)T7HH21S-H224-Cwith ductless indoor unit T7HH21S-H224-E2 of 2 models qualify · AHRI 218003231
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class) (higher)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q6 of 8 models qualify · AHRI 21716260178.0(50 is the typical model of its size class)T7HH25Q-H248-C5 of 6 models qualify · AHRI 218003253
Non-ducted, 3.5–4.5 tons69.9(50 is the typical model of its size class) (higher)HO-MS60-LA-Q6 of 7 models qualify · AHRI 21716252366.0(50 is the typical model of its size class)T7HH22X-H272-C2 of 3 models qualify · AHRI 218003256
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMitsutomoAll-around score, best modelTHERMOCORE SYSTEMSAll-around score, best model
Ducted, up to 1.5 tons95.0(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q11 of 11 models have all five ratings · AHRI 21716257177.4(50 is the typical model of its size class)T7HH25D-H224-C1 of 1 models have all five ratings · AHRI 218003246
Ducted, 2 tons78.8(50 is the typical model of its size class) (higher)RU-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models have all five ratings · AHRI 21716255864.5(50 is the typical model of its size class)T725D-H236-C1 of 1 models have all five ratings · AHRI 218003240
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)HO-MP36-LA-Q14 of 14 models have all five ratings · AHRI 21716251683.6(50 is the typical model of its size class)T7HH25Q-H248-C3 of 3 models have all five ratings · AHRI 218003252
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class) (higher)RO-MS48-LA-Q12 of 12 models have all five ratings · AHRI 21716250482.0(50 is the typical model of its size class)T7HH22X-H272-C2 of 2 models have all five ratings · AHRI 218003255
Ducted, 5 tons and up65.3(50 is the typical model of its size class)RU-SG60-LA-Qwith ducted air handler HD-UG60AL-Q2 of 2 models have all five ratings · AHRI 21716259265.3(50 is the typical model of its size class)T7C20S-H260-Cwith ducted air handler T7C20S-H260-EDT1 of 1 models have all five ratings · AHRI 218003237
Non-ducted, up to 1.5 tons93.8(50 is the typical model of its size class) (higher)HO-SZ06-LA-Qwith ductless indoor unit HW-UZ06-LA-Q19 of 19 models have all five ratings · AHRI 21716253881.9(50 is the typical model of its size class)T7HH25D-H224-C6 of 6 models have all five ratings · AHRI 218003245
Non-ducted, 2 tons74.3(50 is the typical model of its size class)RU-SZ24-LA-Qwith ductless indoor unit HW-UZ24-LA-Q5 of 5 models have all five ratings · AHRI 21716254776.4(50 is the typical model of its size class) (higher)T7HH21S-H224-Cwith ductless indoor unit T7HH21S-H224-E2 of 2 models have all five ratings · AHRI 218003231
Non-ducted, 2.5–3 tons66.3(50 is the typical model of its size class)HO-MP36-LA-Q8 of 8 models have all five ratings · AHRI 21716251578.3(50 is the typical model of its size class) (higher)T7HH25Q-H248-C6 of 6 models have all five ratings · AHRI 218003251
Non-ducted, 3.5–4.5 tons62.6(50 is the typical model of its size class)HO-MS60-LA-Q7 of 7 models have all five ratings · AHRI 21716252163.6(50 is the typical model of its size class) (higher)T7HH22X-H272-C3 of 3 models have all five ratings · AHRI 218003254
Non-ducted, 5 tons and up32.5(50 is the typical model of its size class)RO-MS60-LA-Q1 of 1 models have all five ratings · AHRI 217162506No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMitsutomoTHERMOCORE SYSTEMS
COP at 5°Fbeats 99% · 2.51RU-SZ12-LA-QNon-ducted, up to 1.5 tonsbeats 94% · 2.34T7HH21S-H224-CNon-ducted, 2 tons
Capacity retention at 5°Fbeats 98% · 126%HO-SZ09-LA-QNon-ducted, up to 1.5 tonsbeats 94% · 106%T7HH25Q-H248-CDucted, 2.5–3 tons
HSPF2beats 99% · 11.0HO-MS48-LA-QDucted, 3.5–4.5 tonsbeats 98% · 13.5T7HH21S-H224-CNon-ducted, 2 tons
SEER2beats 96% · 20.4RO-MS48-LA-QDucted, 3.5–4.5 tonsbeats 97% · 25.0T725D-H236-CNon-ducted, 2.5–3 tons
EER2beats 99% · 14.4HO-SZ06-LA-QDucted, up to 1.5 tonsbeats 91% · 15.0T7HH25D-H224-CNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 39,500 Btu/hHO-SG36-LA-QNon-ducted, 2.5–3 tonsbeats 97% · 19,000 Btu/hT7HH25D-H224-CNon-ducted, up to 1.5 tons

More comparisons