OUTES vs TRUENORTH heat pumps
Measured against models of the same size and duct type, TRUENORTH scores higher on 5 of the 6 ratings. OUTES has 7 outdoor models, TRUENORTH has 19 outdoor models. OUTES and TRUENORTH have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- OUTES
- TRUENORTH
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | OUTES | TRUENORTH |
|---|---|---|
| Efficiency index | 29%median — | 42%median — |
| COP at 5°F | 23%median 1.80 | 37%median 1.80 |
| Capacity retention at 5°F | 12%median 46% | 59%median 72% |
| HSPF2 | 25%median 7.5 | 47%median 8.5 |
| SEER2 | 17%median 14.3 | 39%median 17.5 |
| EER2 | 59% (higher)median 11.5 | 33% (higher)median 10.5 |
| Heating capacity at 5°F | 11%median 13,500 Btu/h | 61%median 20,000 Btu/h |
| Outdoor models | 7 | 19 |
| AHRI certifications | 11 | 71 |
Share of models meeting each standard
| Standard | OUTES | TRUENORTH |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 57.9%11 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 52.6%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 68.4%13 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 57.9%11 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- OUTES
- TRUENORTH
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | OUTES | TRUENORTH |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 14% | 3 · index 29% |
| Ducted, 2 tons | 1 · index 23% | 3 · index 40% |
| Ducted, 2.5 to 3 tons | 2 · index 30% | 5 · index 45% |
| Ducted, 3.5 to 4.5 tons | 3 · index 35% | 3 · index 35% |
| Non-ducted, up to 1.5 tons | None | 6 · index 34% |
| Non-ducted, 2 tons | None | 2 · index 49% |
| Non-ducted, 2.5 to 3 tons | None | 3 · index 69% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | OUTESCold-climate score, best model | TRUENORTHCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 36.3(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models qualify · AHRI 218593150 |
| Ducted, 2 tons | None on this board (0 of 1 models qualify) | 50.3(50 is the typical model of its size class)WLWHD(24)ND3MO4 of 4 models qualify · AHRI 218593151 |
| Ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | 55.4(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD36AH2/A-D(U)4 of 4 models qualify · AHRI 218828997 |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 3 models qualify) | 58.2(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)1 of 3 models qualify · AHRI 218828999 |
| Non-ducted, up to 1.5 tons | No models in this size class | 74.0(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147 |
| Non-ducted, 2 tons | No models in this size class | 77.3(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 74.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146 |
All-around best
| Size and duct type | OUTESAll-around score, best model | TRUENORTHAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 13.9(50 is the typical model of its size class)OTD-H18SMR5-A01/SE150with ducted air handler OAH-C18SMR5-A01/SE1501 of 1 models have all five ratings · AHRI 210665591 | 31.8(50 is the typical model of its size class) (higher)WLWHD(18)ND3MO3 of 3 models have all five ratings · AHRI 218593150 |
| Ducted, 2 tons | 23.3(50 is the typical model of its size class)OTD-H24SMR5-A01/SE150with ducted air handler OAH-C24SMR5-A01/SE1501 of 1 models have all five ratings · AHRI 210665592 | 60.8(50 is the typical model of its size class) (higher)WLUD36W/A-D(U)with ducted air handler WLUD24AH2/A-D(U)5 of 5 models have all five ratings · AHRI 218828996 |
| Ducted, 2.5 to 3 tons | 30.2(50 is the typical model of its size class)OTD-H30SMR5-A01/SE150with ducted air handler OAH-C30UMR5-A01/SE1502 of 2 models have all five ratings · AHRI 210665593 | 53.0(50 is the typical model of its size class) (higher)WLWHD(30)ND3MO3 of 3 models have all five ratings · AHRI 218593152 |
| Ducted, 3.5 to 4.5 tons | 35.7(50 is the typical model of its size class)OTD-H42SMR5-C01/SE150with ducted air handler OAH-C42UMR5-A01/SE1503 of 3 models have all five ratings · AHRI 210665595 | 63.3(50 is the typical model of its size class) (higher)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)3 of 3 models have all five ratings · AHRI 218828999 |
| Non-ducted, up to 1.5 tons | No models in this size class | 58.6(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147 |
| Non-ducted, 2 tons | No models in this size class | 72.2(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models have all five ratings · AHRI 218593148 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 70.9(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | OUTES | TRUENORTH |
|---|---|---|
| COP at 5°F | beats 29% · 1.80OTD-H30SMR5-A01/SE150Ducted, 2.5 to 3 tons | beats 89% · 2.21WLWHD(18)ND3MONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 16% · 46%OTD-H42SMR5-C01/SE150Ducted, 3.5 to 4.5 tons | beats 86% · 89%WLWHD(30)ND3MODucted, 2.5 to 3 tons |
| HSPF2 | beats 29% · 7.5OTD-H42SMR5-C01/SE150Ducted, 3.5 to 4.5 tons | beats 82% · 10.0WLWHD(36)ND3MONon-ducted, 2.5 to 3 tons |
| SEER2 | beats 19% · 14.3OTD-H42SMR5-C01/SE150Ducted, 3.5 to 4.5 tons | beats 77% · 17.0WLUD60W/A-D(U)Ducted, 3.5 to 4.5 tons |
| EER2 | beats 68% · 11.5OTD-H42SMR5-C01/SE150Ducted, 3.5 to 4.5 tons | beats 84% · 12.5WLWHD(30)ND3MONon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 15% · 21,000 Btu/hOTD-H60UMR5-C01/SE150Ducted, 3.5 to 4.5 tons | beats 85% · 13,800 Btu/hWLWHD(18)ND3MONon-ducted, up to 1.5 tons |