816 models

Sorted by manufacturer and model.
Page 17 of 33
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
401D5CMTAH48FAKARCOAIRE · D5C Series4 tons48,000 Btu/h · Non-ducted1.8575%9.518.710.036,000CEE 25CEE 26XcelES CC9216765606
402D5CPRAH06AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH06XAK0.5 tons6,000 Btu/h · Non-ducted2.00150%15.633.116.513,500CEE 25CEE 26XcelES CC9215413211
403D5CPRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH09XAK1 ton9,000 Btu/h · Non-ducted2.00113%14.631.516.013,500CEE 25CEE 26XcelES CC9215413212
404D5CPRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH12XAK1 ton12,000 Btu/h · Non-ducted2.00113%12.728.013.513,500CEE 25CEE 26XcelES CC10215413213
405D5CPRAH18AAARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH18XAK1.5 tons18,000 Btu/h · Non-ducted2.34113%15.224.514.022,600CEE 25CEE 26CEE AdvXcelDOEES CC10215413214
406D5CSHAH06AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH06XAK0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.514.57,800CEE 25CEE 26CEE AdvXcelDOEES CC27215324104
407D5CSHAH09AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH12XAK1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.513.511,200CEE 25CEE 26XcelES CC54215324109
408D5CSHAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSOAH12XAK1 ton12,000 Btu/h · Ducted and non-ducted1.9992%10.223.013.011,500CEE 25CEE 26XcelES CC54215324112
409D5CSHAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH18XBK1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.118.212.018,000CEE 25CEE 26XcelES CC73215318904
410D5CSHAH24AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH24XAK2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.213.024,200CEE 25CEE 26XcelES CC46215324124
411D5CSHAH33AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH36XBK3 tons33,000 Btu/h · Ducted and non-ducted2.0097%10.016.711.734,000CEE 25CEE 26XcelES CC19215318906
412D5CSRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH09XAK1 ton9,000 Btu/h · Ducted and non-ducted2.3780%12.526.014.98,000CEE 25CEE 26XcelES CC54215324130
413D5CSRAH12AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH12XAJ1 ton12,000 Btu/h · Non-ducted2.3364%9.523.513.07,700CEE 25CEE 2610215324129
414D5CSRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSFAH12XAK1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.712.78,900CEE 25CEE 26XcelES CC54215324139
415D5CSRAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH18XHK1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.420.013.314,200CEE 25CEE 26XcelES CC73215324148
416D5CSRAH24AAKARCOAIREwith ductless indoor unit D5FPHAH18XAK2 tons24,000 Btu/h · Ducted and non-ducted2.5478%11.723.114.019,600CEE 25CEE 26XcelES CC56215324149
417D5CSRAH30AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH30XBK2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.817.011.020,400CEE 25CEE 2629215413032
418D5CSRAH36AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH36XBK3 tons36,000 Btu/h · Ducted and non-ducted2.0062%7.716.08.623,000None20215413033
419D5CUHAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR1.5 tons17,700 Btu/h · Ducted2.8680%8.516.011.715,000CEE 25CEE 26CEE AdvXcelDOEES CC1,263217906663
420D5CUHAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL1.5 tons18,400 Btu/h · Ducted2.0483%9.016.011.016,800CEE 25CEE 26XcelES CC1,684218483199
421D5CUHAH18AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL1.5 tons18,400 Btu/h · Ducted2.0483%9.016.011.016,800CEE 25CEE 26XcelES CC1,804217399865
422D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR2 tons23,800 Btu/h · Ducted2.8879%8.516.09.819,500CEE 25CEE 26XcelES CC5,100217906665
423D5CUHAH24AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*B2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC4,433218486193
424D5CUHAH24AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*B2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC4,378217635077
425D5CUHAH30AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR2.5 tons28,000 Btu/h · Ducted2.4880%7.815.29.823,800CEE 25CEE 26XcelES CC1,044217906667