Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

816 models

Sorted by manufacturer and model.
Page 4 of 33
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
7627SPA648A**30*CARRIERwith ducted air handler 98-887+TXV+RDS+TDR+E30B5D4 tons45,000 Btu/h · Ducted2.4855%7.815.212.023,800None666218795702
7727SPA660A**30*CARRIERwith ducted air handler 98-8812+TXV+RDS+TDR+E30B6D4.5 tons52,000 Btu/h · Ducted2.2452%7.514.512.028,600None13216411462
7827TPA824A**30*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 58SU*B040M17**122 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 251,669215647843
7927TPA836A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 261,405215628934
8027TPA848A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L4 tons48,500 Btu/h · Ducted2.3251%8.118.013.524,600CEE 25CEE 261,171215560636
8127TPA860A**30*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace 58TN*B135C24**224.5 tons56,000 Btu/h · Ducted2.3452%8.515.511.531,400CEE 25CEE 26729215626616
8227VNA024A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNXB24L*+UI2 tons23,400 Btu/h · Ducted2.0470%9.017.510.516,600CEE 25CEE 26XcelES CC428215662625
8327VNA036A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC852215670616
8427VNA048A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI4 tons46,500 Btu/h · Ducted2.2070%9.519.510.533,000CEE 25CEE 26XcelES CC416215675343
8527VNA060A*030*CARRIER · Infinity 20 VS Heat Pumpwith indoor coil CVAMA6021XMA*+UI and furnace 58CU*B040C17**124.5 tons56,000 Btu/h · Ducted2.1572%8.118.09.543,500CEE 25CEE 26XcelES CC222215682803
8627VNA154A*030*CARRIER · Infinity 21 VS Cold Climate Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 58TN*B090C17**164 tons47,000 Btu/h · Ducted2.0898%10.518.511.550,000CEE 25CEE 26XcelES CC482215588077
8727VNA324A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 58CU*B040C17**122 tons23,200 Btu/h · Ducted2.1081%9.522.013.022,200CEE 25CEE 26XcelES CC444217624599
8827VNA336A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC629215933964
8927VNA348A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 58CU*A100C21**203.5 tons43,500 Btu/h · Ducted2.0076%9.520.510.536,600CEE 25CEE 26XcelES CC346215933974
9027VNA360A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI5 tons58,000 Btu/h · Ducted2.1874%9.020.012.544,500CEE 25CEE 26XcelES CC191215931484
9127VPA924A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36L2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC1,240217934991
9227VPA936A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler F55AA*B36L3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC946217908868
9327VPA948A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler FT5ANBD60L4 tons46,000 Btu/h · Ducted2.3275%10.019.012.536,000CEE 25CEE 26XcelES CC642217907915
9427VPA960A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler F55AA*D60L4.5 tons56,000 Btu/h · Ducted2.1670%9.016.011.740,000CEE 25CEE 26XcelES CC431217918380
95290VAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 88*TB66135C242 tons21,800 Btu/h · Ducted2.7983%8.516.09.819,800CEE 25CEE 26XcelES CC738217676739
96290VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC1,240215670617
97290VAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CP49D3J+TDR and furnace 88*TB36070C143.5 tons43,000 Btu/h · Ducted2.7087%8.516.09.043,000CEE 25CEE 26XcelES CC884217676989
98290VAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)60C3J+TDR and furnace 83*CB60100C214.5 tons51,000 Btu/h · Ducted2.3887%8.118.08.551,000CEE 25CEE 26XcelES CC385217676854
99291VAN054**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 21 VS Cold Climate Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 88*TB48090C174 tons47,000 Btu/h · Ducted2.0898%10.518.511.550,000CEE 25CEE 26XcelES CC469215588078
100293VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 83*CB36040C172 tons23,200 Btu/h · Ducted2.1081%9.522.013.022,200CEE 25CEE 26XcelES CC437217624600

Download CSV of the matching modelsAll 816 matching models, every page, in this order.