Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

11 models

Sorted by manufacturer and model.
Page 1 of 1
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1ECOSZ109DAEMIwith ductless indoor unit ECOWAL09DA1 ton9,000 Btu/h · Non-ducted2.1670%9.719.010.97,000CEE 25CEE 26XcelES CC2215444929
2ECOSZ124DAEMI · ECO Serieswith ductless indoor unit ECOWAL24DA2 tons24,000 Btu/h · Non-ducted2.1171%9.018.59.617,000XcelES CC2215862730
3EMXMZ218DAEMI · EMX Series1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3215444940
4EMXMZ327DAEMI · EMX Series2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3215444943
5EMXMZ436DAEMI · EMX Series3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3215444946
6EMXMZ548DAEMI · EMX Series4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.012.047,000CEE 25CEE 26XcelES CC3215444949
7EMXSZ106DAEMI · EMX Serieswith ductless indoor unit EMXWAL06DA0.5 tons6,000 Btu/h · Non-ducted2.40110%14.825.518.07,700CEE 25CEE 26CEE AdvXcelDOEES CC1215444935
8EMXSZ109DAEMI · EMX Serieswith ductless indoor unit EMXWAL09DA1 ton9,000 Btu/h · Non-ducted1.8096%12.527.415.411,500CEE 25CEE 26XcelES CC1215444936
9EMXSZ112DAEMI · EMX Serieswith ductless indoor unit EMXWAL12DA1 ton12,000 Btu/h · Non-ducted1.8096%10.525.413.411,500CEE 25CEE 26XcelES CC1215444937
10EMXSZ118DAEMI · EMX Serieswith ductless indoor unit EMXWAL18DA1.5 tons18,000 Btu/h · Non-ducted1.92100%11.021.412.518,000CEE 25CEE 26XcelES CC1215444938
11EMXSZ124DAEMI · EMX Serieswith ductless indoor unit EMXWAL24DA2 tons24,000 Btu/h · Non-ducted2.3483%13.521.013.024,200CEE 25CEE 26XcelES CC1215444939

Download CSV of the matching modelsAll 11 matching models, every page, in this order.