- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
179 models
Sorted by manufacturer and model.
| # · Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|
| 26AOUH18KWAS2FUJITSU · AIRSTAGE H-series | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.27 | 77% | 10.5 | 22.0 | 13.2 | 17,000 | CEE 25CEE 26XcelES CC | 3 | 215447685 |
| 27AOUH18KZAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH18KZAS | 1.5 tons18,000 Btu/h · Non-ducted | 2.02 | 118% | 12.5 | 25.5 | 14.0 | 25,400 | CEE 25CEE 26XcelES CC | 2 | 215647921 |
| 28AOUH24KNAS1FUJITSUwith ductless indoor unit ASUH24KNAS | 2 tons22,000 Btu/h · Non-ducted | 2.20 | 67% | 9.0 | 20.0 | 10.5 | 16,000 | CEE 25CEE 26 | 1 | 217617836 |
| 29AOUH24KPAS1FUJITSU · AIRSTAGE H serieswith ductless indoor unit ASUH24KPBS | 2 tons22,000 Btu/h · Non-ducted | 2.16 | 83% | 10.0 | 21.5 | 11.7 | 20,000 | CEE 25CEE 26XcelES CC | 2 | 218381305 |
| 30AOUH24KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit ABUH24KUAS | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 107% | 10.8 | 21.7 | 12.8 | 29,000 | CEE 25CEE 26CEE AdvXcelDOE | 4 | 218814797 |
| 31AOUH24KUAS1FUJITSU · AIRSTAGE H serieswith ducted air handler AMUH24KUAS | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.14 | 91% | 10.1 | 17.7 | 11.8 | 24,600 | CEE 25CEE 26XcelES CC | 4 | 217290594 |
| 32AOUH24KWAH3FUJITSU · AIRSTAGE H-series | 2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 101% | 11.5 | 23.5 | 13.5 | 25,200 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215447693 |
| 33AOUH24KWAS3FUJITSU · AIRSTAGE H-series | 2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.04 | 80% | 10.5 | 23.0 | 13.0 | 19,200 | CEE 25CEE 26XcelES CC | 3 | 215447687 |
| 34AOUH24KZAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH24KZAS | 2 tons22,000 Btu/h · Non-ducted | 2.06 | 102% | 11.9 | 24.0 | 12.5 | 25,800 | CEE 25CEE 26XcelES CC | 2 | 215647924 |
| 35AOUH30KPAS1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH30KPAS | 2.5 tons30,000 Btu/h · Non-ducted | 2.20 | 86% | 10.2 | 22.0 | 11.7 | 25,800 | CEE 25CEE 26XcelES CC | 2 | 215390440 |
| 36AOUH30KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH30KUAS | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.16 | 103% | 11.0 | 23.0 | 13.7 | 33,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217895708 |
| 37AOUH30KUAS1FUJITSU · AIRSTAGE H serieswith ducted air handler AMUH30KUAS | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.18 | 92% | 10.0 | 19.0 | 11.7 | 29,400 | CEE 25CEE 26XcelES CC | 4 | 217290595 |
| 38AOUH36KPAS1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH36KPAS | 3 tons33,000 Btu/h · Non-ducted | 2.20 | 76% | 10.0 | 21.0 | 9.8 | 25,800 | XcelES CC | 2 | 215390441 |
| 39AOUH36KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH36KUAS | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.00 | 105% | 10.7 | 22.0 | 12.7 | 40,000 | CEE 25CEE 26XcelES CC | 4 | 217895709 |
| 40AOUH36KUAS1FUJITSU · AIRSTAGE H serieswith ducted air handler AMUH36KUAS | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.18 | 84% | 9.8 | 17.6 | 10.6 | 32,000 | CEE 25CEE 26XcelES CC | 4 | 217290596 |
| 41AOUH36KWAH4FUJITSU · AIRSTAGE H-series | 3 tons35,200 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 100% | 10.0 | 22.0 | 13.0 | 36,400 | CEE 25CEE 26XcelES CC | 3 | 215735282 |
| 42AOUH36KWAS4FUJITSU · AIRSTAGE H-series | 3 tons34,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 66% | 10.0 | 22.0 | 12.0 | 24,000 | CEE 25CEE 26 | 3 | 215447689 |
| 43AOUH36KWBH4FUJITSU · AIRSTAGE H-series | 3 tons35,200 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 100% | 10.0 | 22.0 | 13.0 | 36,400 | CEE 25CEE 26XcelES CC | 3 | 217994865 |
| 44AOUH42KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH42KUAS | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.02 | 102% | 10.6 | 22.0 | 13.0 | 48,000 | CEE 25CEE 26XcelES CC | 2 | 217895710 |
| 45AOUH42KUAS1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH42KUAS | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.36 | 79% | 10.4 | 19.0 | 10.8 | 37,000 | CEE 25CEE 26XcelES CC | 2 | 215812200 |
| 46AOUH45KWAS5FUJITSU · AIRSTAGE H-series | 3.5 tons43,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.14 | 75% | 10.0 | 22.0 | 12.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 215735280 |
| 47AOUH45KWBS5FUJITSU · AIRSTAGE H-series | 3.5 tons43,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.14 | 80% | 10.0 | 22.0 | 12.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 217994862 |
| 48AOUH48KUAH1FUJITSU · AIRSTAGE H-serieswith ducted air handler AMUH48KUAS | 4 tons45,500 Btu/h · Ducted and non-ducted | 1.96 | 100% | 10.2 | 19.0 | 11.2 | 51,000 | CEE 25CEE 26XcelES CC | 3 | 217895718 |
| 49AOUH48KUAS1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH48KUAS | 4 tons46,000 Btu/h · Ducted and non-ducted | 2.34 | 75% | 10.2 | 18.2 | 10.1 | 38,500 | CEE 25CEE 26XcelES CC | 3 | 215812201 |
| 50AOUK024SSAN7FUJITSU · J-7S | 2 tons24,000 Btu/h · Mixed (multi-zone) | 3.03 | 94% | 11.3 | 22.2 | 15.7 | 26,200 | CEE 25CEE 26XcelES CC | 3 | 216372779 |
Download CSV of the matching modelsAll 179 matching models, every page, in this order.