Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

717 models

Sorted by manufacturer and model.
Page 6 of 29
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
126GWH09AGCXD-D6DNA4D/OGREE · Ductedwith ducted air handler GFH(09)DA-D6DN***/I1 ton9,100 Btu/h · Ducted and non-ducted2.1490%9.222.014.29,500CEE 25CEE 26XcelES CC8216618210
127GWH09ATCXB-A6DNA1B/OGREE · Charmowith ductless indoor unit GWH09ATCXB-A6DN***/I1 ton9,100 Btu/h · Non-ducted1.9079%9.222.012.37,700CEE 25CEE 26XcelES CC3214855373
128GWH09ATCXB-A6DNA1C/OGREE · Charmowith ductless indoor unit GWH09ATCXB-A6DN***/I1 ton9,100 Btu/h · Non-ducted1.8676%8.820.511.97,600CEE 25CEE 26XcelES CC3214215187
129GWH09ATCXB-A6DNA5D/OGREE · Charmowith ductless indoor unit GWH09ATCXB-A6DN***/I1 ton9,100 Btu/h · Non-ducted1.8676%8.820.511.97,600CEE 25CEE 26XcelES CC2216020690
130GWH09ATCXB-D6DNA1B/OGREE · Charmowith ductless indoor unit GWH09ATCXB-D6DN***/I1 ton9,100 Btu/h · Non-ducted1.9079%9.222.012.37,700CEE 25CEE 26XcelES CC3214780391
131GWH09ATCXB-D6DNA1C/OGREE · Charmowith ductless indoor unit GWH09ATCXB-D6DN***/I1 ton9,100 Btu/h · Non-ducted1.9476%8.820.512.57,600CEE 25CEE 26XcelES CC3214061912
132GWH09ATCXB-D6DNA4D/OGREE · Charmowith ductless indoor unit GWH09ATCXB-D6DN***/I1 ton9,100 Btu/h · Non-ducted1.9476%8.820.512.57,600CEE 25CEE 26XcelES CC3215386291
133GWH09AUCXD-A6DNA1C/OGREE · Cliviawith ductless indoor unit GWH09AUCXD-A6DN***/I1 ton9,100 Btu/h · Non-ducted1.8395%10.527.015.09,500CEE 25CEE 26XcelES CC2213925481
134GWH09AUCXD-D6DNA1C/OGREE · Ductedwith ducted air handler GFH(09)DA-D6DN***/I1 ton9,100 Btu/h · Ducted and non-ducted2.1490%9.222.014.29,500CEE 25CEE 26XcelES CC8215406442
135GWH09AVDXE-D6DNA1A/OGREE · Airywith ductless indoor unit GWH09AVDXE-D6DN***/I1 ton9,100 Btu/h · Ducted and non-ducted2.11108%11.230.016.811,500CEE 25CEE 26CEE AdvXcelDOEES CC6214802442
136GWH09AVDXE-D6DNA1B/OGREE · Airywith ductless indoor unit GWH09AVDXE-D6DN***/I1 ton9,100 Btu/h · Ducted and non-ducted2.11108%11.230.016.811,500CEE 25CEE 26CEE AdvXcelDOEES CC6215385452
137GWH09AWCXB-A6DNA1A/OGREEwith ductless indoor unit GWH09AWCXB-A6DN***/I1 ton9,100 Btu/h · Non-ducted1.9079%8.622.012.37,700CEE 25CEE 26Xcel1213879366
138GWH09AWCXB-D6DNA1A/OGREEwith ductless indoor unit GWH09AWCXB-D6DN***/I1 ton9,100 Btu/h · Non-ducted1.9074%8.622.012.37,200CEE 25CEE 26Xcel1213880763
139GWH09AYBXB-A6DNA1A/OGREE · ZENOwith ductless indoor unit GWH09AYBXB-A6DN***/I1 ton9,100 Btu/h · Non-ducted1.8070%8.618.511.97,000CEE 25CEE 26Xcel4216046763
140GWH09AYBXB-D6DNA1A/OGREE · ZENOwith ductless indoor unit GWH09AYBXB-D6DN***/I1 ton9,100 Btu/h · Non-ducted1.8576%8.618.812.37,600CEE 25CEE 26Xcel4216046762
141GWH09BDCXE-D6DNA1C/OGREE · Gloviawith ductless indoor unit GWH09BDCXE-D6DN***/I1 ton9,100 Btu/h · Non-ducted1.90114%10.626.516.012,000CEE 25CEE 26XcelES CC1218425000
142GWH12AGCXD-D6DNA4D/OGREE · Pularwith ductless indoor unit GWH12AGCXD-D6DN***/I1 ton12,000 Btu/h · Ducted and non-ducted1.9592%9.524.513.011,000CEE 25CEE 26XcelES CC8215402266
143GWH12AGDXF-D6DNA2B/OGREE · Pularwith ductless indoor unit GWH12AGDXF-D6DN***/I1 ton12,000 Btu/h · Non-ducted2.00123%9.026.015.714,770CEE 25CEE 26XcelES CC1218644512
144GWH12ATCXB-A6DNA1A/OGREE · Charmowith ductless indoor unit GWH12ATCXB-A6DN***/I1 ton12,000 Btu/h · Non-ducted1.8171%8.519.09.38,500XcelES CC3214640136
145GWH12ATCXB-A6DNA5B/OGREE · Charmowith ductless indoor unit GWH12ATCXB-A6DN***/I1 ton12,000 Btu/h · Non-ducted1.8171%8.519.09.38,500XcelES CC2215887359
146GWH12ATCXB-A6DNA5C/OGREEwith ductless indoor unit GWH12ATCXB-A6DN***/I1 ton11,500 Btu/h · Non-ducted2.3158%8.520.510.97,000None1218722969
147GWH12ATCXB-D6DNA1A/OGREE · Charmowith ductless indoor unit GWH12ATCXB-D6DN***/I1 ton12,000 Btu/h · Non-ducted1.8076%8.519.09.89,100XcelES CC4214640135
148GWH12ATCXB-D6DNA4B/OGREE · Charmowith ductless indoor unit GWH12ATCXB-D6DN***/I1 ton12,000 Btu/h · Non-ducted1.8076%8.519.09.89,100XcelES CC3215402236
149GWH12ATCXD-A6DNA1B/OGREE · Charmowith ductless indoor unit GWH12ATCXD-A6DN***/I1 ton12,000 Btu/h · Non-ducted1.9071%8.521.511.08,500CEE 25CEE 26XcelES CC3213925483
150GWH12ATCXD-D6DNA1B/OGREE · Charmowith ductless indoor unit GWH12ATCXD-D6DN***/I1 ton12,000 Btu/h · Non-ducted1.9078%8.521.511.09,400CEE 25CEE 26XcelES CC3213927350

Download CSV of the matching modelsAll 717 matching models, every page, in this order.