Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
109 models
Sorted by manufacturer and model.
| # · Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|
| 76RHPXYB042AJTFRIGIDAIRE | 3.5 tons40,000 Btu/h · Ducted | 1.55 | 43% | 6.7 | 13.4 | 10.6 | 17,000 | None | 3 | 217469143 |
| 77RHPXYB048AJTFRIGIDAIRE | 4 tons45,500 Btu/h · Ducted | 1.80 | 43% | 6.7 | 13.4 | 10.6 | 19,400 | None | 3 | 217469146 |
| 78RHPXYB060AJTFRIGIDAIRE | 5 tons57,000 Btu/h · Ducted | 1.59 | 43% | 6.7 | 13.4 | 10.6 | 24,400 | None | 3 | 217469149 |
| 79SH4BE5M1SP18KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65BMMX18K-A | 1.5 tons17,800 Btu/h · Ducted | 1.75 | 44% | 7.5 | 14.3 | 11.0 | 7,500 | None | 9 | 216802031 |
| 80SH4BE5M1SP24KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65BMMX24K-A | 2 tons23,400 Btu/h · Ducted | 1.75 | 47% | 7.5 | 14.3 | 11.0 | 10,800 | None | 21 | 216802032 |
| 81SH4BE5M1SP30KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65BMMX30K-B | 2.5 tons29,000 Btu/h · Ducted | 1.75 | 48% | 7.5 | 14.3 | 11.0 | 13,800 | None | 24 | 216802033 |
| 82SH4BE5M1SP36KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65BMMX36K-B | 3 tons34,200 Btu/h · Ducted | 1.75 | 49% | 7.5 | 14.3 | 11.0 | 16,200 | None | 20 | 216802034 |
| 83SH4BE5M1SP42KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65BMMX42K-C | 3.5 tons40,500 Btu/h · Ducted | 1.75 | 48% | 7.5 | 14.3 | 11.0 | 19,700 | None | 12 | 216802035 |
| 84SH4BE5M1SP48KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65EMMX48K-C | 4 tons46,500 Btu/h · Ducted | 1.75 | 47% | 7.5 | 14.3 | 11.0 | 22,000 | None | 11 | 216802036 |
| 85SH4BE5M2SX60KNORDYNE · NORDYNE SH4BE SERIESwith ducted air handler B65VMMX60K-C | 4.5 tons53,500 Btu/h · Ducted | 2.00 | 53% | 7.5 | 14.3 | 10.7 | 31,000 | None | 6 | 216802037 |
| 86SH4BF5M2SX24KNORTEK GLOBAL HVAC LLC · NORTEK GLOBAL HVAC SH4BF SERIESwith ducted air handler B65VMMX24K-B | 2 tons24,000 Btu/h · Ducted | 1.75 | 48% | 8.0 | 16.0 | 11.7 | 11,000 | CEE 25 | 7 | 216508803 |
| 87SH4BF5M2SX36KNORTEK GLOBAL HVAC LLC · NORTEK GLOBAL HVAC SH4BF SERIESwith ducted air handler B65VMMX3648K-C | 3 tons36,000 Btu/h · Ducted | 1.75 | 52% | 8.0 | 16.0 | 11.7 | 17,800 | CEE 25CEE 26 | 7 | 216508804 |
| 88SH4BF5M2SX48KNORTEK GLOBAL HVAC LLC · NORTEK GLOBAL HVAC SH4BF SERIESwith ducted air handler B65VMMX3648K-C | 4 tons45,500 Btu/h · Ducted | 1.75 | 51% | 8.0 | 16.0 | 11.7 | 23,400 | CEE 25CEE 26 | 7 | 216508805 |
| 89SH4BF5M2SX60KNORTEK GLOBAL HVAC LLC · NORTEK GLOBAL HVAC SH4BF SERIESwith ducted air handler B65VMMX60K-C | 4.5 tons53,500 Btu/h · Ducted | 1.75 | 54% | 8.0 | 15.2 | 9.8 | 31,000 | None | 7 | 216508959 |
| 90SH4ME5M1SP24KNORDYNE · NORDYNE SH4ME5 SERIESwith ducted air handler C85DAMX24U-B | 2 tons23,400 Btu/h · Ducted | 1.75 | 50% | 7.5 | 14.3 | 11.0 | 12,000 | None | 4 | 216802044 |
| 91SH4ME5M1SP30KNORDYNE · NORDYNE SH4ME5 SERIESwith ducted air handler C85DAMX3036U-B | 2.5 tons29,600 Btu/h · Ducted | 1.75 | 52% | 7.5 | 14.3 | 11.0 | 15,000 | None | 5 | 216802045 |
| 92SH4ME5M1SP36KNORDYNE · NORDYNE SH4ME5 SERIESwith ducted air handler C85DAMX3036U-B | 3 tons34,600 Btu/h · Ducted | 1.75 | 50% | 7.5 | 14.3 | 11.0 | 17,800 | None | 5 | 216802046 |
| 93SH4ME5M1SP42KNORDYNE · NORDYNE SH4ME5 SERIESwith ducted air handler C85DAMX43U-B | 3.5 tons40,500 Btu/h · Ducted | 1.75 | 51% | 7.5 | 14.3 | 11.0 | 21,000 | None | 4 | 216802047 |
| 94SH4ME5M1SP48KNORDYNE · NORDYNE SH4ME5 SERIESwith indoor coil C85DAMX4960U-B and furnace E7E*-0**H | 4 tons46,000 Btu/h · Ducted | 1.75 | 49% | 7.5 | 14.3 | 11.0 | 23,000 | None | 5 | 216954212 |
| 95UXH24-36MSK3IHGibson · E Serieswith ducted air handler UMD24MSK3IH | 2 tons24,000 Btu/h · Ducted | 2.00 | 96% | 10.0 | 18.0 | 12.5 | 24,000 | CEE 25CEE 26XcelES CC | 14 | 217138206 |
| 96UXH48-60MSK3IHGibson · E Serieswith ducted air handler UMD60MSK3IH | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | 11.5 | 54,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 217138209 |
| 97WHS09SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS09WMB21S | 1 ton9,000 Btu/h · Non-ducted | 2.11 | 60% | 9.0 | 22.5 | 12.5 | 5,400 | CEE 25CEE 26 | 1 | 217101979 |
| 98WHS12SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS12WMB21S | 1 ton12,000 Btu/h · Non-ducted | 1.83 | 63% | 9.0 | 20.0 | 10.0 | 7,500 | CEE 25 | 1 | 217101980 |
| 99WHS18SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS18WMB21S | 1.5 tons18,000 Btu/h · Non-ducted | 2.53 | 74% | 9.8 | 20.0 | 12.0 | 13,400 | CEE 25CEE 26Xcel | 1 | 217101981 |
| 100WHS24SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS24WMB21S | 2 tons24,000 Btu/h · Non-ducted | 1.98 | 76% | 9.0 | 19.5 | 10.6 | 18,200 | CEE 25CEE 26Xcel | 1 | 217101982 |
Download CSV of the matching modelsAll 109 matching models, every page, in this order.