Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

111 models

Sorted by manufacturer and model.
Page 4 of 5
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
76RHPXYC060ADTRUSSELL5 tons57,000 Btu/h · Ducted1.6045%7.215.211.525,000None1216437562
77RHPXYC060AJTRUSSELL · RHPXYC5 tons57,000 Btu/h · Ducted1.6045%7.215.211.525,000None1216437566
78SP14AY18AJ1NRUSSELLwith ducted air handler SH2CY2417STANN1.5 tons17,100 Btu/h · Ducted1.8051%7.514.39.08,600None35214568787
79SP14AY24AJ2NRUSSELLwith ducted air handler RF2TY2421STANS2 tons22,800 Btu/h · Ducted2.0046%7.514.39.010,500None40215772201
80SP14AY30AJ2NRUSSELLwith indoor coil TCFY3621STANM and furnace S972V0855A21UPS2.5 tons28,400 Btu/h · Ducted2.0049%7.514.810.513,900None68218696001
81SP14AY36AC2NRUSSELLwith ducted air handler SH2CY3617STANN3 tons34,200 Btu/h · Ducted——7.514.39.0—None1216011635
82SP14AY36AD2NRUSSELLwith ducted air handler SH2CY3617STANN3 tons34,200 Btu/h · Ducted——7.514.39.0—None1216011638
83SP14AY36AJ2NRUSSELLwith ducted air handler SH2CY3617STANN3 tons34,200 Btu/h · Ducted2.1053%7.514.39.017,400None95214568802
84SP14AY42AC2NRUSSELLwith ducted air handler SH2CY4821STANN3.5 tons40,000 Btu/h · Ducted——7.514.39.0—None1216011633
85SP14AY42AD2NRUSSELLwith ducted air handler SH2CY4821STANN3.5 tons40,000 Btu/h · Ducted——7.514.39.0—None1216011634
86SP14AY42AJ2NRUSSELLwith indoor coil TCFY4824STANM and furnace S801T1505A24UH3.5 tons40,000 Btu/h · Ducted2.2047%7.514.811.718,300None92214592198
87SP14AY48AC2NRUSSELLwith ducted air handler SH2CY4821STANN4 tons45,500 Btu/h · Ducted——7.514.39.0—None1216011636
88SP14AY48AD2NRUSSELLwith ducted air handler SH2CY4821STANN4 tons45,500 Btu/h · Ducted——7.514.39.0—None1216011639
89SP14AY48AJ2NRUSSELLwith indoor coil TCFY4821STANM and furnace S972V0705A21UPS4 tons45,500 Btu/h · Ducted2.1053%7.814.810.524,000None84218696101
90SP14AY60AC2NRUSSELLwith ducted air handler SH2CY6021STANA4.5 tons55,000 Btu/h · Ducted——7.514.39.0—None1216011637
91SP14AY60AD2NRUSSELLwith ducted air handler SH2CY6021STANA4.5 tons55,000 Btu/h · Ducted——7.514.39.0—None1216011640
92SP14AY60AJ2NRUSSELLwith ducted air handler SH2CY6021STANA4.5 tons55,000 Btu/h · Ducted2.1051%7.514.39.027,800None67214568817
93SP15AY18AJ2NRUSSELL · VANTIXwith ducted air handler RF2TY2421STANS1.5 tons17,100 Btu/h · Ducted2.0050%8.115.211.78,600ES CC16216533447
94SP15AY24AJ2NRUSSELL · VANTIXwith ducted air handler RF2TY2421STANS2 tons22,800 Btu/h · Ducted2.1050%7.815.211.711,200None34216533453
95SP15AY30AJ2NRUSSELL · VANTIXwith ducted air handler SH2CY3617STANN2.5 tons28,400 Btu/h · Ducted2.0051%7.815.211.714,600None81215487013
96SP15AY36AC2NRUSSELLwith ducted air handler SH2CY3617STANN3 tons34,200 Btu/h · Ducted——7.514.39.0—None1216011708
97SP15AY36AD2NRUSSELLwith ducted air handler SH2CY3617STANN3 tons34,200 Btu/h · Ducted——7.514.39.0—None2216011709
98SP15AY36AJ2NRUSSELL · VANTIXwith ducted air handler SH2VY3621STACN3 tons34,200 Btu/h · Ducted2.1052%7.816.012.017,800None86216030766
99SP15AY42AC2NRUSSELLwith ducted air handler SH2CY4821STANN3.5 tons40,000 Btu/h · Ducted——7.514.39.0—None2216011710
100SP15AY42AD2NRUSSELLwith ducted air handler SH2CY4821STANN3.5 tons40,000 Btu/h · Ducted——7.514.39.0—None2216011711

Download CSV of the matching modelsAll 111 matching models, every page, in this order.