Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

12 models

Sorted by manufacturer and model.
Page 1 of 1
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1RD16AY36AJVCRUSSELL · VANTIXwith indoor coil TCFY3624MTANM and furnace S972V1155A24UPS3 tons34,200 Btu/h · Ducted2.4058%8.517.011.019,200CEE 25CEE 26ES CC197218719597
2RD16AY48AJVCRUSSELLwith indoor coil TCFY4824STANM and furnace S921T1005A21M43.5 tons43,000 Btu/h · Ducted2.1058%8.115.210.025,000CEE 25ES CC127217350635
3RD18AY24AJVCRUSSELL · VANTIXwith ducted air handler RH2VY3617STACN2 tons21,200 Btu/h · Ducted2.0071%9.518.011.717,000CEE 25CEE 26XcelES CC53216613176
4RD18AY36AJVCRUSSELLwith ducted air handler TCFY4821STANM+RXMD-C032.5 tons31,600 Btu/h · Ducted2.3080%7.514.39.025,400CEE 25CEE 26XcelES CC194216613183
5RD18AY48AJVCRUSSELLwith ducted air handler TCFY6024STANM+RXMD-C033.5 tons41,500 Btu/h · Ducted2.2076%8.115.210.031,400CEE 25CEE 26XcelES CC129216613188
6RD18AY60AJVCRUSSELL · VANTIXwith indoor coil TCFY6021STAAM and furnace S972V0705A21UPS4 tons48,500 Btu/h · Ducted2.2075%8.116.010.036,200CEE 25CEE 26XcelES CC73218729679
7SP15AY42AJ2NRUSSELL · VANTIXwith ducted air handler SH2CY4821STANN3.5 tons40,000 Btu/h · Ducted2.1049%7.815.211.719,700CEE 25ES CC72215487019
8SP15AY48AJ2NRUSSELL · VANTIXwith ducted air handler SH2CY4821STANN4 tons45,500 Btu/h · Ducted2.2052%7.815.211.723,600CEE 25CEE 26ES CC75215415467
9SP19AY24AJVCRUSSELL · VANTIXwith indoor coil TCFY2421HEAAM and furnace S972V0603A17UPS2 tons22,800 Btu/h · Ducted2.1077%8.521.013.017,500CEE 25CEE 26XcelES CC34218728661
10SP19AY36AJVCRUSSELL · VANTIXwith indoor coil TCFY3621MEAAM and furnace S972V0603A17UPS3 tons34,200 Btu/h · Ducted2.2077%8.520.012.026,200CEE 25CEE 26XcelES CC19218728679
11SP19AY48AJVCRUSSELL · VANTIXwith indoor coil TCFY4821SEAAM and furnace S972V0705A21UPS4 tons45,500 Btu/h · Ducted2.2076%8.519.012.034,800CEE 25CEE 26Xcel17218728694
12SP19AY60AJVCRUSSELL · VANTIXwith indoor coil TCFY6021SEAAM and furnace S972V0855A21UPS4.5 tons53,500 Btu/h · Ducted2.1084%8.117.010.045,000CEE 25CEE 26Xcel14218728708

Download CSV of the matching modelsAll 12 matching models, every page, in this order.