SL25XPV-036-230A**

ADP · AHRI 213360248

Size class: 3 tons · 33,400 Btu/h · Ducted

Numbers are from one AHRI-certified pairing of this outdoor unit with an indoor unit, with indoor coil LH35/36F9 and furnace EL297UH045XV36B (it has 24 pairings; the one with the best 5°F efficiency is shown).

Efficiency on a 5°F day
1.82
COP at 5°F
Below the middleBeats 37% of its size class
Heating power kept at 5°F
78%
Capacity retention at 5°F
GoodBeats 67% of its size class
Winter-long heating efficiency
8.8
HSPF2
GoodBeats 64% of its size class
Summer-long cooling efficiency
21.0
SEER2
Top 10%Beats 98% of its size class
Hot-day cooling efficiency
12.5
EER2
Top 10%Beats 95% of its size class
Heat output at 5°F
25,800 Btu/h
Heating capacity at 5°F
GoodBeats 66% of its size class

Cold-climate pick?

Yes. Cold-climate score 56.4 out of 100 in its size class, on its pairing AHRI 213360257. See the top picks of its size

Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.

All-around score

77.4 out of 100 in its size class (heating 55.5, cooling 99.3), on its pairing AHRI 213360276. See the all-around best of its size

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Rebate standards

A model meets a standard when at least one of its certified pairings does. Programs can have other rules too.

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Side by side with another model

Only models of the same size class (ducted, 2.5–3 tons) can be compared, so their numbers mean the same thing.

What size is my system?

Tons and Btu

A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.

Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Size classes used here

  • Up to 1.5 tonsunder 21,000 Btu/h
  • 2 tons21,000–26,999 Btu/h
  • 2.5–3 tons27,000–38,999 Btu/h
  • 3.5–4.5 tons39,000–56,999 Btu/h
  • 5 tons and up57,000 Btu/h and up

The advanced view lists every model with filters for brand, standard, size and type, sortable by any rating.