Ratings
Certified ratings
DPSH05BAPB5****E35**G*
Daikin · AHRI 216030338
Size class: 4.5 tons · 55,000 Btu/h · Ducted
Numbers are from one AHRI-certified pairing of this outdoor unit with an indoor unit.
- Efficiency on a 5°F day
- 1.72
- COP at 5°F
- Below the middleBeats 10% of its size class
- Heating power kept at 5°F
- 68%
- Capacity retention at 5°F
- Below the middleBeats 42% of its size class
- Winter-long heating efficiency
- 7.9
- HSPF2
- Below the middleBeats 44% of its size class
- Summer-long cooling efficiency
- 19.5
- SEER2
- GreatBeats 89% of its size class
- Hot-day cooling efficiency
- 11.9
- EER2
- GreatBeats 82% of its size class
- Heat output at 5°F
- 33,200 Btu/h
- Heating capacity at 5°F
- Below the middleBeats 43% of its size class
Cold-climate pick?
Not a pick. Keeps 67% of its heat at 5°F; the bar is 70%.
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
All-around score
59.2 out of 100 in its size class (heating 32.6, cooling 85.9). See the all-around best of its size
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Rebate standards
- CEE 2025 Tier 1 (Split ASHP): does not meet itDoes not meet it
- CEE 2026 Tier 1 (Split ASHP): does not meet itDoes not meet it
- CEE Advanced Tier (Split ASHP): does not meet itDoes not meet it
- Xcel Energy Colorado cold-climate ASHP (2025): does not meet itDoes not meet it
- DOE Cold Climate Heat Pump Challenge: does not meet itDoes not meet it
- ENERGY STAR Cold Climate: does not meet itDoes not meet it
A model meets a standard when at least one of its certified pairings does. Programs can have other rules too.
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Side by side with another model
Only models of the same size class (ducted, 3.5–4.5 tons) can be compared, so their numbers mean the same thing.
What size is my system?
Tons and Btu
A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.
Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Size classes used here
- Up to 1.5 tonsunder 21,000 Btu/h
- 2 tons21,000–26,999 Btu/h
- 2.5–3 tons27,000–38,999 Btu/h
- 3.5–4.5 tons39,000–56,999 Btu/h
- 5 tons and up57,000 Btu/h and up
The advanced view lists every model with filters for brand, standard, size and type, sortable by any rating.
Open the advanced view