- Insights
- Check a model
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Check a heat pump’s certified ratings
Type the outdoor unit’s model number from its nameplate, or the AHRI reference number from your quote. You will see its ratings, how it compares with others of its size, and the rebate standards it meets.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Partial model numbers work. AHRI numbers find the pairing listed for each model.
Ratings
Certified ratings
FAC-24HPI/230X17N
fuji comfort · AHRI 216778969
Size class: 2 tons · 23,000 Btu/h · Ductless
Numbers are from one AHRI-certified pairing of this outdoor unit with an indoor unit, with ductless indoor unit FAC-24HPI/230X17U.
- Efficiency on a 5°F day
- 1.80
- COP at 5°F
- Below the middleBeats 16% of its size class
- Heating power kept at 5°F
- 54%
- Capacity retention at 5°F
- Below the middleBeats 3% of its size class
- Winter-long heating efficiency
- 9.5
- HSPF2
- Below the middleBeats 44% of its size class
- Summer-long cooling efficiency
- 17.0
- SEER2
- Below the middleBeats 4% of its size class
- Hot-day cooling efficiency
- 9.5
- EER2
- Below the middleBeats 6% of its size class
- Heat output at 5°F
- 12,000 Btu/h
- Heating capacity at 5°F
- Below the middleBeats 4% of its size class
Cold-climate pick?
Not a pick. Keeps 53% of its heat at 5°F; the bar is 70%.
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
All-around score
13.4 out of 100 in its size class (heating 21.4, cooling 5.3). See the all-around best of its size
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Rebate standards
- CEE 2025 Tier 1 (Split ASHP): does not meet itDoes not meet it
- CEE 2026 Tier 1 (Split ASHP): does not meet itDoes not meet it
- CEE Advanced Tier (Split ASHP): does not meet itDoes not meet it
- Xcel Energy Colorado cold-climate ASHP (2025): does not meet itDoes not meet it
- DOE Cold Climate Heat Pump Challenge: does not meet itDoes not meet it
- ENERGY STAR Cold Climate: does not meet itDoes not meet it
A model meets a standard when at least one of its certified pairings does. Programs can have other rules too.
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Side by side with another model
Only models of the same size class (ductless, 2 tons) can be compared, so their numbers mean the same thing.
What size is my system?
Tons and Btu
A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.
Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Size classes used here
- Up to 1.5 tonsunder 21,000 Btu/h
- 2 tons21,000–26,999 Btu/h
- 2.5–3 tons27,000–38,999 Btu/h
- 3.5–4.5 tons39,000–56,999 Btu/h
- 5 tons and up57,000 Btu/h and up
The advanced view lists every model with filters for brand, standard, size and type, sortable by any rating.
Open the advanced view