- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
6,849 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 6626XH648E2S11COLEMANwith indoor coil D(A,C,E)60A4K+TDR and furnace Z9ES120D20SMPS1 | York | 3.5 tons44,500 Btu/h · Ducted | 2.91 | 72% | 8.1 | 16.0 | 11.7 | 33,000 | CEE 25CEE 26Xcel | 3,175 | 218448057 |
| 6627XH660E2S11COLEMANwith ducted air handler DM59A4K+JMC20D2SN1+TDR | York | 4.5 tons51,000 Btu/h · Ducted | 2.86 | 65% | 8.2 | 16.0 | 11.7 | 38,000 | CEE 25CEE 26 | 1,533 | 218026324 |
| 6628XH936E2C11COLEMAN · LX SERIESwith ducted air handler JHC36B5AD2SS1+CC | York | 3 tons35,000 Btu/h · Ducted | 2.00 | 93% | 9.0 | 19.0 | 11.0 | 32,200 | CEE 25CEE 26XcelES CC | 823 | 218026877 |
| 6629XH960E2C11COLEMAN · LX SERIESwith ducted air handler JHC48D5CG2SS1+CC | York | 4 tons48,000 Btu/h · Ducted | 2.00 | 95% | 8.5 | 21.0 | 11.0 | 44,000 | CEE 25CEE 26XcelES CC | 829 | 218026835 |
| 6630YD524E2D11YORK · YD5with ducted air handler JDE24E5XX2DS1 | York | 2 tons24,000 Btu/h · Ducted | 1.84 | 72% | 8.5 | 18.0 | 11.7 | 17,200 | CEE 25CEE 26XcelES CC | 6 | 218450367 |
| 6631YD536E2D11YORK · YD5with ducted air handler JDE36E5XX2DS1 | York | 3 tons34,200 Btu/h · Ducted | 1.90 | 65% | 8.5 | 17.0 | 10.4 | 22,400 | CEE 25CEE 26XcelES CC | 12 | 218619077 |
| 6632YD560E2D11YORK · YD5with indoor coil CDM48C5XXS1 and furnace Y82E080C16LMPS1 | York | 3.5 tons43,000 Btu/h · Ducted | 1.90 | 72% | 8.5 | 16.0 | 10.5 | 32,200 | CEE 25CEE 26XcelES CC | 16 | 218787951 |
| 6633YDC36E2D11YORK · YDCwith ducted air handler JDU36F5XX2DS1 | York | 3 tons36,400 Btu/h · Ducted | 2.10 | 100% | 10.0 | 19.0 | 12.0 | 36,600 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218619070 |
| 6634YDC60E2D11YORK · YDCwith ducted air handler JDU48F5XX2DS1 | York | 4 tons48,500 Btu/h · Ducted | 2.10 | 100% | 10.0 | 19.0 | 12.0 | 48,500 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218450357 |
| 6635YDV36E2D11YORK · YDVwith ducted air handler JDE24E5XX2DS1 | York | 2 tons24,000 Btu/h · Ducted | 2.01 | 73% | 9.5 | 20.0 | 13.0 | 17,400 | CEE 25CEE 26XcelES CC | 10 | 218450360 |
| 6636YDV60E2D11YORK · YDVwith ducted air handler JDE48F5XX2DS1 | York | 4 tons47,000 Btu/h · Ducted | 2.00 | 70% | 9.5 | 18.5 | 12.0 | 33,600 | CEE 25CEE 26XcelES CC | 7 | 218450361 |
| 6637YH524E2S11YORKwith ducted air handler L(E,F)W30CJ | York | 2 tons23,600 Btu/h · Ducted | 2.37 | 62% | 7.8 | 15.2 | 12.0 | 13,800 | CEE 25CEE 26 | 253 | 216436783 |
| 6638YH536E2S11YORKwith ducted air handler L(E,G)M36EK | York | 2.5 tons32,600 Btu/h · Ducted | 2.86 | 65% | 7.5 | 14.5 | 11.0 | 20,200 | CEE 25CEE 26 | 802 | 218805067 |
| 6639YH548E2S11YORKwith ducted air handler L(E,G)M60AK | York | 4 tons46,000 Btu/h · Ducted | 2.79 | 63% | 7.8 | 15.2 | 11.7 | 29,200 | CEE 25CEE 26 | 1,139 | 218805070 |
| 6640YH560E2S11YORKwith ducted air handler L(E,G)M60CK | York | 4 tons49,500 Btu/h · Ducted | 2.70 | 69% | 7.5 | 14.8 | 11.2 | 37,800 | CEE 25CEE 26 | 401 | 218805071 |
| 6641YH618E2S11YORK · LX SERIESwith ducted air handler CTF30B5ACS1+JME12B2SN1 | York | 1.5 tons17,000 Btu/h · Ducted | 2.34 | 53% | 8.0 | 16.0 | 12.5 | 8,900 | CEE 25CEE 26 | 450 | 218416881 |
| 6642YH624E2S11YORKwith indoor coil CH36A3K+TDR and furnace Y81E100B12LMPS1 | York | 2 tons21,600 Btu/h · Ducted | 2.59 | 63% | 7.8 | 15.5 | 11.0 | 14,400 | CEE 25CEE 26 | 440 | 217284406 |
| 6643YH630E2S11YORKwith ducted air handler A(E,F)W36J+TDR | York | 2.5 tons27,800 Btu/h · Ducted | 2.44 | 63% | 7.5 | 15.2 | 11.5 | 17,600 | CEE 25CEE 26 | 181 | 218640167 |
| 6644YH636E2S11YORKwith ducted air handler A(E,F)M36J+TDR | York | 2.5 tons32,200 Btu/h · Ducted | 2.83 | 66% | 8.0 | 16.0 | 12.0 | 22,800 | CEE 25CEE 26 | 695 | 217752631 |
| 6645YH648E2S11YORKwith ducted air handler D(A,C,E)60D3J+TDR | York | 3.5 tons44,500 Btu/h · Ducted | 2.90 | 75% | 8.1 | 14.3 | 11.0 | 36,000 | CEE 25CEE 26Xcel | 718 | 217455200 |
| 6646YH660E2S11YORKwith ducted air handler D(A,C,E)60D3J+TDR | York | 4.5 tons51,000 Btu/h · Ducted | 2.83 | 68% | 8.1 | 14.3 | 11.0 | 39,500 | CEE 25CEE 26 | 446 | 217455239 |
| 6647YH936E2C11YORK · LX SERIESwith ducted air handler JHC36B5AD2SS1+CC | York | 3 tons35,000 Btu/h · Ducted | 2.00 | 93% | 9.0 | 19.0 | 11.0 | 32,200 | CEE 25CEE 26XcelES CC | 278 | 218026602 |
| 6648YH960E2C11YORK · LX SERIESwith ducted air handler JHC48D5CG2SS1+CC | York | 4 tons48,000 Btu/h · Ducted | 2.00 | 95% | 8.5 | 21.0 | 11.0 | 44,000 | CEE 25CEE 26XcelES CC | 264 | 218026601 |
| 6649YHKF12YJ6DXUO-XYORKwith ductless indoor unit YHKF12XJ6DXU-RX | York | 1 ton12,000 Btu/h · Non-ducted | 2.15 | 67% | 10.0 | 21.0 | 12.0 | 8,200 | CEE 25CEE 26 | 1 | 216740987 |
| 6650YHKF12YJMEXVO-XYORKwith ductless indoor unit YHKF12XJMEXV-RX | York | 1 ton12,000 Btu/h · Non-ducted | 2.32 | 78% | 10.1 | 23.0 | 12.0 | 9,600 | CEE 25CEE 26Xcel | 1 | 216720983 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 6,849 models; narrow the filters for the rest.