Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

6,854 models

Sorted by manufacturer and model.
Page 82 of 275
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2026DRA1H12S2ADurastar · DRA Serieswith ductless indoor unit DRAL0612F2ADurastar1 ton12,000 Btu/h · Ducted and non-ducted1.9992%10.023.013.011,500CEE 25CEE 26XcelES CC6215359253
2027DRA1H18S2ADurastar · DRA Serieswith ducted air handler DRAM18F2ADurastar1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.018.012.018,000CEE 25CEE 26CEE AdvXcelDOEES CC9215374882
2028DRA1H24S2ADurastar · DRA Serieswith ductless indoor unit DRAC24F2ADurastar2 tons23,400 Btu/h · Ducted and non-ducted2.2395%11.620.712.023,800CEE 25CEE 26XcelES CC6215359266
2029DRA1H33S2ADurastar · DRA Serieswith ductless indoor unit DRAW33F2ADurastar3 tons33,000 Btu/h · Non-ducted1.9196%10.520.011.734,600CEE 25CEE 26XcelES CC1215359269
2030DRA1U09S2ADurastar · DRA Serieswith ductless indoor unit DRAW09F2ADurastar1 ton9,000 Btu/h · Ducted and non-ducted2.3382%13.024.614.78,200CEE 25CEE 26XcelES CC7215359270
2031DRA1U12S2ADurastar · DRA Serieswith ductless indoor unit DRAS12F2ADurastar1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.612.78,900CEE 25CEE 26XcelES CC6215359280
2032DRA1U18S2ADurastar · DRA Serieswith ducted air handler DRADH18F2ADurastar1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.320.013.314,200CEE 25CEE 26XcelES CC8215359289
2033DRA1U24S2ADurastar · DRA Serieswith ductless indoor unit DRAC24F2ADurastar2 tons24,000 Btu/h · Ducted and non-ducted2.3074%10.522.012.018,500CEE 25CEE 26XcelES CC5215359291
2034DRA3H18M2ADurastar · DRA SeriesDurastar1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.013.018,000CEE 25CEE 26XcelES CC3215359215
2035DRA3U18M2ADurastar · DRA SeriesDurastar1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3077%10.020.012.014,600CEE 25CEE 26XcelES CC3215359231
2036DRA4H28M2ADurastar · DRA SeriesDurastar2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%9.519.012.027,000CEE 25CEE 26XcelES CC3215359219
2037DRA4U28M2ADurastar · DRA SeriesDurastar2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.523.012.219,000CEE 25CEE 26XcelES CC3215359233
2038DRA5H36M2ADurastar · DRA SeriesDurastar3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00106%10.419.412.038,000CEE 25CEE 26XcelES CC3215359222
2039DRA5U36M2ADurastar · DRA SeriesDurastar3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%10.023.112.026,000CEE 25CEE 26XcelES CC3215359236
2040DRA6H48M2ADurastar · DRA SeriesDurastar4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0098%10.221.212.048,000CEE 25CEE 26XcelES CC3215415532
2041DRA6H55M2ADurastar · DRA SeriesDurastar4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1087%10.720.011.748,000CEE 25CEE 26XcelES CC3215415536
2042DRA6U48M2ADurastar · DRA SeriesDurastar4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1075%10.021.311.736,000CEE 25CEE 26XcelES CC3215415538
2043DRA6U60M2ADurastar · DRA SeriesDurastar5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1067%9.218.010.040,000CEE 25CEE 263215359213
2044DRE1U09S2ADurastarwith ductless indoor unit DREW09S2ALDurastar1 ton9,000 Btu/h · Non-ducted1.8673%9.519.011.77,300CEE 25CEE 26Xcel1217727837
2045DRE1U12S2ADurastarwith ductless indoor unit DREW12S2ALDurastar1 ton12,000 Btu/h · Non-ducted1.7975%9.520.010.59,000CEE 25CEE 26Xcel1217727839
2046DRU1H18S2ADurastar · DRU Serieswith ducted air handler DRUF1820S2ADurastar1.5 tons18,000 Btu/h · Ducted2.10103%10.819.312.119,600CEE 25CEE 26CEE AdvXcelDOEES CC7217465406
2047DRU1H24S2ADurastar · DRU Serieswith ducted air handler DRUF2420S2ADurastar2 tons24,000 Btu/h · Ducted1.9678%10.517.510.819,600CEE 25CEE 26XcelES CC8217465407
2048DRU1H30S2ADurastarwith ducted air handler D(A,C,E)37B2J+TDRDurastar2.5 tons28,400 Btu/h · Ducted2.5380%8.514.89.023,800CEE 25CEE 26XcelES CC11217752026
2049DRU1H36S2ADurastarwith ducted air handler D(A,C,E)37B2J+TDRDurastar2.5 tons31,400 Btu/h · Ducted2.1578%8.114.310.027,000CEE 25CEE 26XcelES CC23217752027
2050DRU1H42S2ADurastar · DRU Serieswith ducted air handler DRUM4260S2ADurastar3.5 tons42,000 Btu/h · Ducted1.9092%9.516.711.746,000CEE 25CEE 26XcelES CC1215374888

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 6,854 models; narrow the filters for the rest.