Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DOE Cold Climate Heat Pump Challenge: 137 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
New to heat pump ratings? The Simple view explains them in plain words →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 1.4%
- Qualifying models
- 137
- Qualifying certifications
- 4,698
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,085 |
| 1.90 to under 2.00 | 1,249 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 470 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 531 |
| 85 to under 90% | 415 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 691 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 239 |
| 7.3 to under 7.5 | 65 |
| 7.5 to under 7.8 | 1,051 |
| 7.8 to under 8.0 | 534 |
| 8.0 to under 8.3 | 814 |
| 8.3 to under 8.5 | 123 |
| 8.5 to under 8.8 | 1,436 |
| 8.8 to under 9.0 | 268 |
| 9.0 to under 9.3 | 946 |
| 9.3 to under 9.5 | 361 |
| 9.5 to under 9.8 | 692 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 623 |
| 10.3 to under 10.5 | 171 |
| 10.5 to under 10.8 | 303 |
| 10.8 to under 11.0 | 79 |
| 11.0 to under 11.3 | 175 |
| 11.3 to under 11.5 | 85 |
| 11.5 to under 11.8 | 116 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons2.4% · 75 of 3,130
- 2 tons3.1% · 44 of 1,437
- 2.5–3 tons0.5% · 14 of 2,588
- 3.5–4.5 tons0.2% · 4 of 2,136
- 5 tons and up0% · 0 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 2.4% · 75 of 3,130 |
| 2 tons | 3.1% · 44 of 1,437 |
| 2.5–3 tons | 0.5% · 14 of 2,588 |
| 3.5–4.5 tons | 0.2% · 4 of 2,136 |
| 5 tons and up | 0% · 0 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 0.7% | 30 / 4,549 |
| Non-ducted | 1.9% | 60 / 3,236 |
| Ducted and non-ducted | 2.5% | 47 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-24ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-24W-HH-MC | 1HVAC | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 210857298 |
| 2ACIQ-24ZPL-HP230BACIQ · ACIQwith ductless indoor unit ACIQ-24W-HH-MB | ACIQ | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207825534 |
| 3DLCURAH18ABKACIQ · HORIZONTAL VS HPwith ducted air handler FMA4X18**AL | ACIQ | 1.5 tons17,400 Btu/h · Ducted | 2.44 | 108% | 8.5 | 16.0 | CEE 25CEE 26CEE AdvXcelDOE | 35 | 213072380 |
| 44TXD2036A10NU**ADPwith ducted air handler F,PE*E32930 | ADP | 2 tons23,000 Btu/h · Ducted | 2.10 | 107% | 8.9 | 16.0 | CEE 25CEE 26CEE AdvXcelDOE | 15 | 212396546 |
| 5BMY12HH26CBLUERIDGE · BM serieswith ductless indoor unit BMM12LW | BlueRidge | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.10 | 103% | 10.7 | 24.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 209550311 |
| 6BMY24HH22CBLUERIDGE · BM serieswith ductless indoor unit BMY24HH22WM | BlueRidge | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 207339186 |
| 7BOVD-36HDN1-M20GBOSCHwith indoor coil D(A,C,E)36A34+TDR and furnace BGH96M100C5B | Bosch | 2.5 tons29,800 Btu/h · Ducted | 3.03 | 126% | 8.7 | 18.0 | CEE 25CEE 26CEE AdvXcelDOE | 113 | 215375432 |
| 8BZ33-HYP24OUT2-G2-PBreeze33 · BZ33 serieswith ductless indoor unit BZ33-HYP24WALL2-G2-P | Breeze33 | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 207862073 |
| 9HSZ24H424ZMOBreeze33 · HS serieswith ductless indoor unit FC24H424ZMI | Breeze33 | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 11.0 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 211277595 |
| 1038MARBQ24AA3CARRIER · 38MAR-serieswith ductless indoor unit 40MAHBQ24XA3 | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 28 | 206348138 |
| 1138MPRBQ18AA3PAYNE · 38MP-serieswith ductless indoor unit DHMPHBQ18XA3 | Carrier | 1.5 tons18,000 Btu/h · Non-ducted | 2.89 | 120% | 11.0 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 207826654 |
| 1238MURAQ18AB3CARRIER · 38M serieswith ducted air handler 40MULAQ24XBX + CI | Carrier | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26CEE AdvXcelDOEES CC | 28 | 213372204 |
| 1338MURAQ18AB3*CARRIERwith indoor coil D(A,C,E)24B44+TDR and furnace 59TP6B040V17**12 | Carrier | 1.5 tons17,600 Btu/h · Ducted | 2.94 | 67% | 8.1 | 15.5 | CEE 25CEE 26CEE AdvXcelDOE | 2,494 | 213205782 |
| 1438MURAQ24AB3*PAYNE HEATING AND COOLINGwith indoor coil D(A,C,E)36B34+TDR and furnace PG96MSAA48060B | Carrier | 2 tons23,600 Btu/h · Ducted | 3.09 | 73% | 9.5 | 16.5 | CEE 25CEE 26CEE AdvXcelDOE | 4,576 | 215866302 |
| 1538MURAQ30AB3*CARRIERwith indoor coil D(A,C,E)30D44+TDR and furnace 58TP*A090V17**16 | Carrier | 2.5 tons29,600 Btu/h · Ducted | 2.81 | 69% | 7.7 | 15.0 | CEE 25CEE 26CEE AdvXcelDOE | 3,793 | 213206826 |
| 1638MURAQ36AB3*CARRIERwith indoor coil D(A,C,E)36C34+TDR and furnace 59TP6B080V21**20 | Carrier | 3 tons35,000 Btu/h · Ducted | 2.97 | 75% | 7.5 | 15.5 | CEE 25CEE 26CEE AdvXcelDOE | 4,874 | 213207313 |
| 17DLCPRBH18AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFPHBH18XAK | Carrier | 1.5 tons18,000 Btu/h · Non-ducted | 2.89 | 120% | 11.0 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 207826644 |
| 18DLCSRBH24AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFSHCH24XAK | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 132 | 208447615 |
| 19DLCURAH18ABKTEMPSTARwith indoor coil D(A,C,E)24B44+TDR and furnace *80VTL0451412B | Carrier | 1.5 tons17,700 Btu/h · Ducted | 2.61 | 70% | 8.5 | 16.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6,119 | 213820984 |
| 20DLCURAH24AAKTEMPSTARwith indoor coil D(A,C,E)24B44+TDR and furnace *80MS(N,L)0451412A | Carrier | 2 tons22,800 Btu/h · Ducted | 2.92 | 81% | 8.1 | 16.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 11,115 | 213821016 |
| 21DLCURAH24ABKTEMPSTARwith indoor coil D(A,C,E)30C44+TDR and furnace *92ESN0802120A | Carrier | 2 tons23,800 Btu/h · Ducted | 3.03 | 73% | 8.5 | 17.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 11,255 | 213204888 |
| 22WDLCURAH18ABKGRANDAIREwith ducted air handler FMA4X18**AL | Carrier | 1.5 tons17,400 Btu/h · Ducted | 2.44 | 108% | 8.5 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 286 | 211264940 |
| 23WDLCURAH24ABKGRANDAIREwith indoor coil WLA*244BA and furnace WFST060B048A | Carrier | 2 tons23,200 Btu/h · Ducted | 2.34 | 73% | 8.5 | 16.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 519 | 213076381 |
| 24CHF24CD(O)COMFORTSTAR · C serieswith ductless indoor unit CHF24CD(I) | COMFORTSTAR | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207658929 |
| 25CH-HPR24-230VOC&H · CH serieswith ductless indoor unit CH-24MASTWM-230VI | Cooper&Hunter | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 20 | 207740504 |