Both views use the same certified data. This device remembers your choice.
ENERGY STAR Cold Climate: 2,418 qualifying heat pumps
Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).
Simple view, for homeowners: top picks by size and what each rating measures →
U.S. EPAData as of updated · sources
- Share of models
- 24.6%
- Qualifying models
- 2,418
- Qualifying certifications
- 12,921
- Paths
- Listing
Criteria
No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.
Source: U.S. EPA
Qualification by size
- Up to 1.5 tons33.4% · 1,068 of 3,201
- 2 tons29.6% · 430 of 1,454
- 2.5 to 3 tons18.5% · 486 of 2,633
- 3.5 to 4.5 tons19% · 413 of 2,174
- 5 tons and up5.8% · 21 of 362
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 33.4% · 1,068 of 3,201 |
| 2 tons | 29.6% · 430 of 1,454 |
| 2.5 to 3 tons | 18.5% · 486 of 2,633 |
| 3.5 to 4.5 tons | 19% · 413 of 2,174 |
| 5 tons and up | 5.8% · 21 of 362 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 15.1% | 698 / 4,608 |
| Non-ducted | 23.3% | 772 / 3,317 |
| Ducted and non-ducted | 49.9% | 948 / 1,899 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 170 of 403 | 42.2% |
| Midea | 152 of 408 | 37.3% |
| Mitsubishi Electric | 144 of 400 | 36% |
| Hisense | 71 of 160 | 44.4% |
| Lennox | 62 of 375 | 16.5% |
| Carrier | 62 of 701 | 8.8% |
| Fujitsu | 46 of 164 | 28% |
| Rheem | 45 of 291 | 15.5% |
| ECO AC | 36 of 49 | 73.5% |
| BlueRidge | 36 of 83 | 43.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-06W-HH-MC | 1HVAC | 0.5 tons6,000 Btu/h · Non-ducted | 2.09 | 107% | 13.6 | 26.5 | CEE 25CEE 26XcelES CC | 2 | 210857294 |
| 2ACIQ-09ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-09W-HH-MB | 1HVAC | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.97 | 88% | 11.5 | 28.1 | CEE 25CEE 26XcelES CC | 5 | 207825512 |
| 3ACIQ-12-EHPB1HVAC · ACIQ Serieswith ducted air handler ACIQ-12-AHB | 1HVAC | 1 ton12,000 Btu/h · Ducted | 2.00 | 85% | 9.0 | 17.5 | CEE 25CEE 26XcelES CC | 1 | 214602071 |
| 4ACIQ-12ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-12FM-HH-MC | 1HVAC | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 99% | 10.7 | 24.2 | CEE 25CEE 26XcelES CC | 7 | 210857311 |
| 5ACIQ-18-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-18W-WM | 1HVAC | 1.5 tons18,000 Btu/h · Ducted | 2.30 | 99% | 10.8 | 19.3 | CEE 25CEE 26XcelES CC | 5 | 213433229 |
| 6ACIQ-18Z-HH-M2B1HVAC · ACIQ | 1HVAC | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.83 | 100% | 9.8 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 207825564 |
| 7ACIQ-18ZPL-HP230B1HVAC · ACIQ serieswith ducted air handler ACIQ-18AHB-HH-M | 1HVAC | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.00 | 89% | 9.6 | 17.6 | CEE 25CEE 26XcelES CC | 8 | 210857354 |
| 8ACIQ-24-EHPB1HVAC · ACIQ serieswith ducted air handler ACIQ-24W-WM | 1HVAC | 2 tons24,000 Btu/h · Ducted | 2.33 | 75% | 10.2 | 17.0 | CEE 25CEE 26XcelES CC | 4 | 213433226 |
| 9ACIQ-24-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-24W-WM | 1HVAC | 2 tons24,000 Btu/h · Ducted | 2.00 | 92% | 10.5 | 17.5 | CEE 25CEE 26XcelES CC | 5 | 213433230 |
| 10ACIQ-24ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-24W-HH-MB | 1HVAC | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207825515 |
| 11ACIQ-27Z-HH-M3B1HVAC · ACIQ | 1HVAC | 2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 89% | 10.6 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 207825567 |
| 12ACIQ-30-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-30-ACL | 1HVAC | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26XcelES CC | 6 | 212394313 |
| 13ACIQ-36-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-36-ACL | 1HVAC | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 212394314 |
| 14ACIQ-36-HPC1HVACwith ducted air handler ACIQ-36-AHB | 1HVAC | 3 tons36,000 Btu/h · Ducted | 1.96 | 92% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 213492117 |
| 15ACIQ-36Z-HH-M4B1HVAC · ACIQ | 1HVAC | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 97% | 10.3 | 22.2 | CEE 25CEE 26XcelES CC | 3 | 207825570 |
| 16ACIQ-36ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-36CD-HH-MB | 1HVAC | 3 tons36,000 Btu/h · Ducted and non-ducted | 1.98 | 86% | 11.0 | 16.5 | XcelES CC | 3 | 210857301 |
| 17ACIQ-48-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-48-AHB | 1HVAC | 4 tons47,000 Btu/h · Ducted | 1.90 | 92% | 9.4 | 15.6 | ES CC | 2 | 208106640 |
| 18ACIQ-48Z-HH-M5B1HVAC · ACIQ | 1HVAC | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 92% | 9.8 | 21.8 | CEE 25CEE 26XcelES CC | 3 | 207825573 |
| 19ACIQ-48ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-48CD-HH-MB | 1HVAC | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.02 | 88% | 10.3 | 14.3 | ES CC | 3 | 210857302 |
| 20ACIQ-55Z-HH-M5B1HVAC · ACIQ | 1HVAC | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.77 | 85% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 210857362 |
| 21ACIQ-60HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-60AHB | 1HVAC | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | ES CC | 2 | 210857353 |
| 22ACIQ-60ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-60CD-HH-MB | 1HVAC | 4.5 tons55,000 Btu/h · Ducted and non-ducted | 1.97 | 93% | 9.5 | 15.8 | XcelES CC | 2 | 210857303 |
| 23ACIQ-PHH1748000K000V1HVAC · Extreme Heat Inverter Rooftop | 1HVAC | 4 tons47,000 Btu/h · Ducted | 1.80 | 98% | 8.5 | 17.8 | CEE 25CEE 26XcelES CC | 1 | 215387220 |
| 24ACIQ-PHH1760000K000V1HVAC · Extreme Heat Inverter Rooftop | 1HVAC | 4.5 tons56,000 Btu/h · Ducted | 1.80 | 79% | 8.3 | 17.0 | XcelES CC | 1 | 215387221 |
| 25ES-18Z-M2B1HVAC · ES SERIES | 1HVAC | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 66% | 10.5 | 22.9 | CEE 25CEE 26XcelES CC | 3 | 210857365 |