Heat pump efficiency data for 9,640 certified models
Every split air-source heat pump certified by AHRI with R-410A, joined with NEEP cold-climate ratings and ENERGY STAR listings. Counts are certified models, not sales.
New to heat pump ratings? The Simple view explains them in plain words →
Heat pump market dataData as of updated · sources
- Outdoor models
- 9,640
- Manufacturers
- 278
- Brand names
- 344
- Marketed names, grouped under their manufacturer
- AHRI certifications
- 737,594
- Each is one outdoor + indoor pairing
- Ducted model (sample)
- Non-ducted model (sample)
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Dots: 1,200 of 11,475 models, a fixed sample drawn from every size and duct type in proportion; the grey shapes count all of them, half a ton at a time. A model is plotted through its representative certification; the few beyond the axis range are counted but not drawn.
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Key facts
- 9,640 heat pump outdoor models from 278 manufacturers are certified with R-410A, across 737,594 AHRI-certified combinations. Details: 9,640 heat pump outdoor models from 278 manufacturers are certified with R-410A, across 737,594 AHRI-certified combinations.
- 48.4% of these models (4,663) have at least one certified combination that meets CEE 2025 Tier 1. Details: 48.4% of these models (4,663) have at least one certified combination that meets CEE 2025 Tier 1.
- Among QMID-verified manufacturers, the highest COP at 5°F is 3.70, from the York RHP15048B21 (ducted, 3.5–4.5 tons) (AHRI 213612208). The leaderboards compare each model only with units of the same size and duct type. Details: Among QMID-verified manufacturers, the highest COP at 5°F is 3.70, from the York RHP15048B21 (ducted, 3.5–4.5 tons) (AHRI 213612208). The leaderboards compare each model only with units of the same size and duct type.
- 48.7% of models with a published 5°F rating keep at least 70% of their rated heating capacity at 5°F. Details: 48.7% of models with a published 5°F rating keep at least 70% of their rated heating capacity at 5°F.
- Carrier has the most certified models in this group: 701, or 7.3% of the catalog (a count of certified models, not of sales). Details: Carrier has the most certified models in this group: 701, or 7.3% of the catalog (a count of certified models, not of sales).
How many models meet each standard
A model counts when at least one of its certified indoor pairings meets every criterion on its own.
Cold-climate tier = CEE Advanced, which uses the same rating criteria as the DOE Cold Climate Heat Pump Challenge (HSPF2 8.5, COP 2.1 at 5°F, 100% capacity at 5°F). It has no SEER2/EER2 path, so a model can reach it without meeting Tier 1.
Show the data as a table
| Duct type | Highest CEE Tier 1 | Cold-climate tier | Models |
|---|---|---|---|
| Ducted | CEE 2026 | Yes | 28 |
| Ducted | CEE 2026 | No | 1,045 |
| Ducted | CEE 2025 only | No | 104 |
| Ducted | Below Tier 1 | Yes | 2 |
| Ducted | Below Tier 1 | No | 3,370 |
| Non-ducted | CEE 2026 | Yes | 60 |
| Non-ducted | CEE 2026 | No | 1,802 |
| Non-ducted | CEE 2025 only | No | 93 |
| Non-ducted | Below Tier 1 | No | 1,281 |
| Ducted + ductless heads | CEE 2026 | Yes | 47 |
| Ducted + ductless heads | CEE 2026 | No | 1,408 |
| Ducted + ductless heads | CEE 2025 only | No | 76 |
| Ducted + ductless heads | Below Tier 1 | No | 324 |
Source: AHRI Directory, criteria from CEE and DOE · as of
| Standard | Share of models | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP)Consortium for Energy Efficiency | 48.4% | 4,663 |
| CEE 2026 Tier 1 (Split ASHP)Consortium for Energy Efficiency | 45.5% | 4,390 |
| CEE Advanced Tier (Split ASHP)Consortium for Energy Efficiency | 1.4% | 137 |
| Xcel Energy Colorado cold-climate ASHP (2025)Xcel Energy | 37.6% | 3,627 |
| DOE Cold Climate Heat Pump ChallengeU.S. Department of Energy | 1.4% | 137 |
| ENERGY STAR Cold ClimateU.S. EPA | 25.2% | 2,434 |
Cold-weather leaders
Top cold-climate picks first: Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F. One model per manufacturer, among manufacturers with a QMID on file. The two single-rating boards beside it are ranked by that one rating only.
Top cold-climate picks, all sizes
- 1LMU421HHVLGNon-ducted, 3.5–4.5 tonsHeat kept at 5°F 100% (beats 98%)Efficiency at 5°F 2.29 (beats 98%)Seasonal efficiency 11.0 (beats 96%)97.4score
- 2NAXSPH06B112A*Mitsubishi ElectricNon-ducted, up to 1.5 tonsHeat kept at 5°F 121% (beats 98%)Efficiency at 5°F 2.46 (beats 98%)Seasonal efficiency 11.9 (beats 96%)97.3score
- 3AOUG12LZAS1FujitsuNon-ducted, up to 1.5 tonsHeat kept at 5°F 138% (beats 99%)Efficiency at 5°F 2.32 (beats 93%)Seasonal efficiency 12.9 (beats 98%)96.9score
- 438MURAQ36AB3*CarrierDucted, 2.5–3 tonsHeat kept at 5°F 115% (beats 99%)Efficiency at 5°F 2.34 (beats 90%)Seasonal efficiency 11.5 (beats 100%)96.4score
- 5DLCPRBH18AAKMideaNon-ducted, up to 1.5 tonsAlso sold as MDV MOD30-18HFN1-MZ20W, Arcoaire DLCPRBH18AAK, Payne 38MPRBQ18AA3; also listed as 38MPRBQ18AA3Heat kept at 5°F 120% (beats 97%)Efficiency at 5°F 2.89 (beats 99%)Seasonal efficiency 11.0 (beats 88%)95.0score
Ranked by COP at 5°F only
- 1ARUN038GSS4LGNon-ducted, 2.5–3 tons3.19beats 100%
- 2PUZ-A30NHA7***Mitsubishi ElectricNon-ducted, 2.5–3 tonsAlso sold as Trane / Mitsubishi Electric TRUZA0301HA702.90beats 100%
- 3MCY-MAP0367HS-UL*CarrierNon-ducted, 2.5–3 tons2.70beats 100%
- 4AOU48RLAVS4FujitsuNon-ducted, 3.5–4.5 tons2.91beats 100%
- 5THE2B42T21YorkDucted, 2.5–3 tons3.44beats 100%
Ranked by capacity retention at 5°F only
How efficient is a typical heat pump at 5°F?
Half of the 7,758 models with a 5°F rating reach a COP of 1.93 or more, and the middle half sit between 1.80 and 2.10. CEE Tier 1 asks for at least 1.75; the cold-climate tier for 2.1.
- Models per 0.1 COP
- Smoothed shape
- Middle 50% / 80%
- Standard threshold
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,085 |
| 1.90 to under 2.00 | 1,249 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 470 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: CEE 2025–26 / Xcel 1.75 | 1.75 |
| Baseline: CEE Adv. / DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory, NEEP · as of
What happens to capacity as it gets colder
Among the models listed by NEEP, a typical ducted unit still delivers 62% of its 47°F capacity at 5°F, and a typical non-ducted one 62%; efficiency falls from a COP near 3.2 to 2.06 over the same range.
- Ducted (median, middle 50%)
- Non-ducted (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 47°F | 93 | 100% | 100% | 100% | 100% | 100% |
| Ducted, 17°F | 93 | 59% | 62% | 68% | 80% | 89% |
| Ducted, 5°F | 93 | 47% | 54% | 62% | 77% | 89% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 47°F | 93 | 2.81 | 3.1 | 3.24 | 3.53 | 3.73 |
| Ducted, 17°F | 93 | 2.1 | 2.2 | 2.4 | 2.59 | 2.96 |
| Ducted, 5°F | 93 | 1.83 | 1.9 | 2.06 | 2.33 | 2.62 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Non-ducted, 47°F | 160 | 100% | 100% | 100% | 100% | 100% |
| Non-ducted, 17°F | 160 | 61% | 65% | 73% | 90% | 100% |
| Non-ducted, 5°F | 160 | 50% | 56% | 62% | 77% | 100% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Non-ducted, 47°F | 160 | 2.66 | 2.93 | 3.25 | 4 | 4.1 |
| Non-ducted, 17°F | 160 | 2.06 | 2.15 | 2.3 | 2.46 | 2.66 |
| Non-ducted, 5°F | 160 | 1.87 | 2 | 2.02 | 2.2 | 2.66 |
Source: NEEP ccASHP list · as of
The refrigerant switch, as AHRI recorded it
New split heat pumps moved from R-410A to low-GWP refrigerants under the AIM Act. This view counts every active certification of both groups, ordered by AHRI reference number.
- R-410A
- R-454B
- R-32
- Other
Reference numbers stand in for dates: AHRI issues them in increasing order, and certification dates are not published. 12,793 older certifications sit in the sparse early bands before the first one shown, and 1,897 have a reference outside the 9-digit series.
Show the data as a table
| References from | R-410A | R-454B | R-32 | Other |
|---|---|---|---|---|
| 206,000,000 | 4,513 | 0 | 0 | 309 |
| 206,500,000 | 10,471 | 0 | 0 | 26 |
| 207,000,000 | 2,049 | 0 | 0 | 66 |
| 207,500,000 | 10,207 | 0 | 0 | 30 |
| 208,000,000 | 2,003 | 0 | 0 | 70 |
| 208,500,000 | 5,149 | 0 | 3 | 20 |
| 209,000,000 | 12,194 | 0 | 1 | 12 |
| 209,500,000 | 4,737 | 0 | 0 | 18 |
| 210,000,000 | 51,924 | 0 | 4 | 6 |
| 210,500,000 | 43,275 | 0 | 4 | 252 |
| 211,000,000 | 42,080 | 0 | 15 | 653 |
| 211,500,000 | 53,746 | 0 | 0 | 24 |
| 212,000,000 | 50,773 | 0 | 8 | 10 |
| 212,500,000 | 55,087 | 0 | 12 | 66 |
| 213,000,000 | 95,900 | 0 | 18 | 78 |
| 213,500,000 | 119,779 | 0 | 61 | 984 |
| 214,000,000 | 59,960 | 122,707 | 49 | 140 |
| 214,500,000 | 40,634 | 17,182 | 216 | 261 |
| 215,000,000 | 15,881 | 12,652 | 15,407 | 43 |
| 215,500,000 | 7,892 | 122,420 | 1,264 | 3 |
| 216,000,000 | 2,549 | 49,374 | 744 | 15 |
| 216,500,000 | 6,171 | 88,977 | 2,837 | 28 |
| 217,000,000 | 27,814 | 119,559 | 2,064 | 233 |
| 217,500,000 | 236 | 136,562 | 3,041 | 97 |
| 218,000,000 | 110 | 111,142 | 3,031 | 3,012 |
| 218,500,000 | 48 | 88,731 | 1,927 | 41 |
Source: AHRI Directory · as of
Largest catalogs
Share of certified outdoor models by manufacturer. A large catalog is not the same as a large market share.
Show the data as a table
| Group | Share of models |
|---|---|
| Carrier | 7.3% · 701 |
| Midea | 4.2% · 402 |
| Gree | 4.1% · 395 |
| Mitsubishi Electric | 3.9% · 373 |
| Daikin | 3.8% · 367 |
| Lennox | 3.2% · 313 |
| Trane | 3.2% · 309 |
| Rheem | 3% · 291 |
| York | 1.9% · 179 |
| Fujitsu | 1.7% · 164 |
The other 268 manufacturers hold 63.8% (6,146 models). All manufacturers
Sizes and duct types
| Size | Models |
|---|---|
| Up to 1.5 tons | 3,130 |
| 2 tons | 1,437 |
| 2.5–3 tons | 2,588 |
| 3.5–4.5 tons | 2,136 |
| 5 tons and up | 349 |
| Type | Models |
|---|---|
| Ducted | 4,549 |
| Non-ducted (mini-split) | 3,236 |
| Both (certified with ducted and non-ducted indoor units) | 1,855 |
All sections
- LeadersTop cold-climate picks, and the top models on each single rating, ranked against models of the same size and duct type.
- ManufacturersPeer scores and ranks per manufacturer, catalog size and concentration.
- Compare two manufacturersPeer scores, standards, sizes and standout models for any pair.
- StandardsCEE, DOE cold-climate, Xcel and ENERGY STAR: criteria, pass rates, what fails.
- RecordsHighest certified values, best per peer group, small manufacturers that outscore the largest.
- New certificationsNewest AHRI references and the R-410A to low-GWP switch.
- OEM familiesIdentical certified ratings sold under more than one brand.
- Explore modelsFilter and sort every certified outdoor model.
- Methodology and FAQSources, sync dates, ranking rules and definitions.