Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
1HVAC heat pumps: how do their ratings compare?
A typical 1HVAC heat pump beats 61% of similar heat pumps (same size and type), which is well above average. 1HVAC has 70 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
61%
of similar heat pumps beaten by its typical model
Well above average1HVAC has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 90 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 57%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 59%
- Winter-long heating efficiencyHSPF2Beats 71%
- Summer-long cooling efficiencySEER2Beats 64%
- Hot-day cooling efficiencyEER2Beats 55%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want 1HVAC’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
87%
meet CEE 2025 Tier 1, the level many utility rebates use.
61 models. All brands: 57%.
74%
meet Xcel Energy Colorado’s cold-climate rebate levels.
52 models. All brands: 53%.
4%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
3 models. All brands: 3%.
Top 1HVAC cold-climate picks, by size
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
8 of 1HVAC’s 8 models of this size and type qualify.
- 1ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC1HVAC2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 2ACIQ-24-HP32with ducted air handler ACIQ-24-AH321HVAC2 tons · 24,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 3ACIQ-24-HPDwith ducted air handler ACIQ-24-PAH1HVAC2 tons · 24,000 Btu/h · DuctedKeeps 86% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 4EZ-24-HPBwith ducted air handler EZ-24-AHB1HVAC2 tons · 23,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.87 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 5ACIQ-24-EHPDwith ducted air handler ACIQ-24W-WMB1HVAC2 tons · 24,000 Btu/h · DuctedKeeps 78% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.96 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.4 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has 1HVAC’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view