Both views use the same certified data. This device remembers your choice.
COSTWAY heat pumps: how do their ratings compare?
A typical COSTWAY heat pump beats 48% of similar heat pumps (same size and type), which is about average. COSTWAY has 71 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
48%
of similar heat pumps beaten by its typical model
About averageRanked 26 among brands with a QMID on file. Based on 69 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 50%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 40%
- Winter-long heating efficiencyHSPF2Beats 50%
- Summer-long cooling efficiencySEER2Beats 53%
- Hot-day cooling efficiencyEER2Beats 40%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Rebate standards
72%
meet CEE 2025 Tier 1, the level many utility rebates use.
51 models. All brands: 57%.
56%
meet Xcel Energy Colorado’s cold-climate rebate levels.
40 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models. All brands: 3%.
Top COSTWAY cold-climate picks, by size
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
6 of COSTWAY’s 6 models of this size and type qualify.
- 1FP10982USwith ducted air handler FP10985USCOSTWAY3 tons · 34,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 2FP11135USCOSTWAYAlso listed as FP11135US3 tons · 34,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 3FP11019USwith ducted air handler FP11022USCOSTWAY3 tons · 34,000 Btu/h · DuctedKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 4FP11134USCOSTWAYAlso listed as FP11134US2.5 tons · 27,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.88 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
Advanced view: COSTWAY’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.
Open the advanced view