Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
KLIMACOM heat pumps: how do their ratings compare?
A typical KLIMACOM heat pump beats 31% of similar heat pumps (same size and type), which is well below average. KLIMACOM has 4 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
31%
of similar heat pumps beaten by its typical model
Well below averageKLIMACOM has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 4 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 63%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 31%
- Winter-long heating efficiencyHSPF2Beats 14%
- Summer-long cooling efficiencySEER2Beats 43%
- Hot-day cooling efficiencyEER2Beats 9%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want KLIMACOM’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
0%
meet CEE 2025 Tier 1, the level many utility rebates use.
0 models. All brands: 57%.
0%
meet Xcel Energy Colorado’s cold-climate rebate levels.
0 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 3%.
Top KLIMACOM cold-climate picks, by size
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
4 of KLIMACOM’s 4 models of this size and type qualify.
- 1ND-10H2KLIMACOMAlso listed as ND1-10H21 ton · 10,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Seasonal efficiency
- 7.5 (HSPF2)
- Below the middle
- 2ND-10H1KLIMACOMAlso listed as ND1-10H11 ton · 10,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 7.5 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has KLIMACOM’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view