Pioneer heat pumps: how do their ratings compare?

A typical Pioneer heat pump beats 48% of similar heat pumps (same size and type), which is about average. Pioneer has 46 heat pump models in this list.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Overall score

48%

of similar heat pumps beaten by its typical model

About average

Ranked 24 among brands with a QMID on file. Based on 57 models with every rating.

Pioneer, rating by ratingStrongest on winter-long heating efficiency (beats 58%), weakest on hot-day cooling efficiency (beats 40%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 42%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 44%
  • Winter-long heating efficiencyHSPF2Beats 58%
  • Summer-long cooling efficiencySEER2Beats 57%
  • Hot-day cooling efficiencyEER2Beats 40%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 74%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    34 models. All brands: 57%.

    See them

  • 70%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    32 models. All brands: 53%.

    See them

  • 0%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    None of its models. All brands: 3%.

Pioneer all-around best, by size

5 of Pioneer’s 5 models of this size and type have all five ratings.

  1. 1YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHGPioneer2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 60.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.99 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.4 (HSPF2)
    Great
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    58.9score / 100Heating 60 · Cooling 58
  2. 2YN024GLSI25RPHwith ductless indoor unit WT024GLSI25HLHPioneer2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 59.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    93% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    58.5score / 100Heating 59 · Cooling 58
  3. 3YN024GLSI20RPFwith ductless indoor unit WT024GLSI20HLFPioneer2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 68% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    68% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Good
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    43.1score / 100Heating 48 · Cooling 38
  4. 4YN024GLUI20RPEwith ductless indoor unit WT024GLUI20HLEPioneer2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    29.9score / 100Heating 29 · Cooling 31
  5. 5YN024GLUI17RPDwith ductless indoor unit WT024GLUI17HLDPioneer2 tons · 23,000 Btu/h · DuctlessNot a cold-climate pick: keeps 53% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    54% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    14.6score / 100Heating 23 · Cooling 6

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What to do next

Advanced view: Pioneer’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter