Both views use the same certified data. This device remembers your choice.
Pioneer heat pumps: how do their ratings compare?
A typical Pioneer heat pump beats 48% of similar heat pumps (same size and type), which is about average. Pioneer has 46 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
48%
of similar heat pumps beaten by its typical model
About averageRanked 24 among brands with a QMID on file. Based on 57 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 42%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 44%
- Winter-long heating efficiencyHSPF2Beats 58%
- Summer-long cooling efficiencySEER2Beats 57%
- Hot-day cooling efficiencyEER2Beats 40%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Rebate standards
74%
meet CEE 2025 Tier 1, the level many utility rebates use.
34 models. All brands: 57%.
70%
meet Xcel Energy Colorado’s cold-climate rebate levels.
32 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models. All brands: 3%.
Top Pioneer cold-climate picks, by size
Showing Ductless, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
2 of Pioneer’s 5 models of this size and type qualify.
- 1YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHGPioneer2 tons · 23,000 Btu/h · DuctlessKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.4 (HSPF2)
- Great
- 2YN024GLSI25RPHwith ductless indoor unit WT024GLSI25HLHPioneer2 tons · 24,000 Btu/h · DuctlessKeeps 93% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.