Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Rheem heat pumps: how do their ratings compare?
A typical Rheem heat pump beats 54% of similar heat pumps (same size and type), which is about average. Rheem has 291 heat pump models in this list, also sold as Mainline, RUUD, SURE, Weatherking.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Overall score
54%
of similar heat pumps beaten by its typical model
About averageRanked 16 among brands with a QMID on file. Based on 232 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 69%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 59%
- Winter-long heating efficiencyHSPF2Beats 49%
- Summer-long cooling efficiencySEER2Beats 44%
- Hot-day cooling efficiencyEER2Beats 46%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want Rheem’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
40%
meet CEE 2025 Tier 1, the level many utility rebates use.
117 models. All brands: 48%.
35%
meet Xcel Energy Colorado’s cold-climate rebate levels.
102 models. All brands: 38%.
6%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
16 models. All brands: 1%.
Top Rheem cold-climate picks, by size
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
24 of Rheem’s 64 models of this size and type qualify.
- 1RO1HHZ30AJ8Swith ducted air handler RIMHHZ30AJ8SRheem2.5 tons · 30,000 Btu/h · DuctedKeeps 93% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.04 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Top 10%
- 2RO1HHZ36AJ8Swith ducted air handler RIMHHZ36AJ8SRheem3 tons · 36,000 Btu/h · DuctedKeeps 86% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.08 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.8 (HSPF2)
- Great
- 3UP18AZ36AJVCwith indoor coil RCFZ6021SEAAM and furnace R802V0754A17DZRheem (sold as RUUD)3 tons · 34,200 Btu/h · DuctedKeeps 127% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 127% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
- 4SP18AZ36AJVCwith ducted air handler SHMVZ6021SEACARheem (sold as SURE)Also sold as Mainline MLP18AZ36AJVC3 tons · 34,200 Btu/h · DuctedKeeps 121% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 121% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
- 5RP18AZ36AJVCwith indoor coil RCFZ6021SEAAM and furnace R98VB085M521URheem3 tons · 34,200 Btu/h · DuctedKeeps 126% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 126% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has Rheem’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view