Both views use the same certified data. This device remembers your choice.
1HVAC vs Bosch: heat pump ratings compared
Against heat pumps of the same size and type, a typical 1HVAC model beats 62% and a typical Bosch model 63%. Bosch rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
1HVAC
62%
of similar heat pumps beaten by its typical model
Well above average70 models listed
Bosch
63%
of similar heat pumps beaten by its typical model
Well above average70 models listed
- Efficiency on a 5°F dayCOP at 5°F1HVAC: Beats 58%Bosch: Beats 63%
- Heating power kept at 5°FCapacity at 5°F vs 47°F1HVAC: Beats 60%Bosch: Beats 63%
- Winter-long heating efficiencyHSPF21HVAC: Beats 71%Bosch: Beats 55%
- Summer-long cooling efficiencySEER21HVAC: Beats 65%Bosch: Beats 55%
- Hot-day cooling efficiencyEER21HVAC: Beats 56%Bosch: Beats 64%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- 1HVAC
- 87%
- Bosch
- 63%
Xcel CC
- 1HVAC
- 74%
- Bosch
- 56%
CEE Advanced
- 1HVAC
- 4%
- Bosch
- 10%
ENERGY STAR CC
- 1HVAC
- 77%
- Bosch
- 57%
All-around best, ductless 5 tons and up
Showing Ductless, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
1HVAC
- 1ES-55Z-M6C1HVAC5 tons · 60,000 Btu/h · DuctlessNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 65% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 22.0 (SEER2)
- Great
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
Bosch
- 1BOHA-60MTB-M18SBosch5 tons · 60,000 Btu/h · DuctlessCold-climate pick, score 52.1Meets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.87 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.1 (HSPF2)
- Great
- Cooling efficiency
- 19.5 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
- 2BOHA-60RTB-M18SBosch5 tons · 60,000 Btu/h · DuctlessCold-climate pick, score 48.7Meets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.84 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.8 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.