Both views use the same certified data. This device remembers your choice.
1HVAC vs HITACHI: heat pump ratings compared
Against heat pumps of the same size and type, a typical 1HVAC model beats 62% and a typical HITACHI model 67%. HITACHI rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
1HVAC
62%
of similar heat pumps beaten by its typical model
Well above average70 models listed
HITACHI
67%
of similar heat pumps beaten by its typical model
Well above average66 models listed
- Efficiency on a 5°F dayCOP at 5°F1HVAC: Beats 58%HITACHI: Beats 65%
- Heating power kept at 5°FCapacity at 5°F vs 47°F1HVAC: Beats 60%HITACHI: Beats 62%
- Winter-long heating efficiencyHSPF21HVAC: Beats 71%HITACHI: Beats 73%
- Summer-long cooling efficiencySEER21HVAC: Beats 65%HITACHI: Beats 59%
- Hot-day cooling efficiencyEER21HVAC: Beats 56%HITACHI: Beats 75%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- 1HVAC
- 87%
- HITACHI
- 97%
Xcel CC
- 1HVAC
- 74%
- HITACHI
- 85%
CEE Advanced
- 1HVAC
- 4%
- HITACHI
- 17%
ENERGY STAR CC
- 1HVAC
- 77%
- HITACHI
- 80%
All-around best, ducted 2.5 to 3 tons
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
1HVAC
- 1ACIQ-36Z-HH-M5C1HVAC3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.4 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.4 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2ACIQ-36ZPL-HP230Cwith ducted air handler ACIQ-36CD-HH-MC1HVAC3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 83.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 11.1 (HSPF2)
- Top 10%
- Cooling efficiency
- 17.7 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3ACIQ-27Z-HH-M4C1HVAC2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 73.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
HITACHI
- 1PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQHITACHI2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 87.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 99% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.6 (SEER2)
- Top 10%
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 2PAS-36BUFASDQ1with ducted air handler PPIM-B36UFA1DQHITACHI3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 87.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 10.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.6 (SEER2)
- Top 10%
- Hot-day cooling
- 12.8 (EER2)
- Top 10%
- 3PAS-30BUFASDQ1-LACwith ducted air handler PPIM-B30UFA1DQHITACHI2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 81.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 94% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.13 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view