agtana vs CHANGHONG: heat pump ratings compared
Against heat pumps of the same size and type, a typical agtana model beats 21% and a typical CHANGHONG model 33%. CHANGHONG rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
agtana
21%
of similar heat pumps beaten by its typical model
Well below average5 models listed
CHANGHONG
33%
of similar heat pumps beaten by its typical model
Well below average5 models listed
- Efficiency on a 5°F dayCOP at 5°Fagtana: Beats 57%CHANGHONG: Beats 81%
- Heating power kept at 5°FCapacity at 5°F vs 47°Fagtana: Beats 3%CHANGHONG: Beats 8%
- Winter-long heating efficiencyHSPF2agtana: Beats 4%CHANGHONG: Beats 14%
- Summer-long cooling efficiencySEER2agtana: Beats 14%CHANGHONG: Beats 40%
- Hot-day cooling efficiencyEER2agtana: Beats 25%CHANGHONG: Beats 23%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- agtana
- 40%
- CHANGHONG
- 40%
Xcel CC
- agtana
- 0%
- CHANGHONG
- 0%
CEE Advanced
- agtana
- 0%
- CHANGHONG
- 0%
ENERGY STAR CC
- agtana
- 0%
- CHANGHONG
- 0%
All-around best, ductless up to 1.5 tons
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
agtana
- 1AGAC-18AW1with ductless indoor unit AGAC-18AG1agtana1.5 tons · 17,100 Btu/h · DuctlessNot a cold-climate pick: keeps 55% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 55% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.22 (COP at 5°F)
- Great
- Winter efficiency
- 8.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.1 (SEER2)
- Below the middle
- Hot-day cooling
- 11.6 (EER2)
- Below the middle
- 2AGAC-12BW1with ductless indoor unit AGAC-12BG1agtana1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 48% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 48% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.67 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.1 (SEER2)
- Below the middle
- Hot-day cooling
- 10.8 (EER2)
- Below the middle
- 3AGAC-12AW1with ductless indoor unit AGAC-12AG1agtana1 ton · 12,100 Btu/h · DuctlessNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 52% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.76 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.1 (SEER2)
- Below the middle
- Hot-day cooling
- 8.8 (EER2)
- Below the middle
CHANGHONG
- 1CSDH-12DAwith ductless indoor unit CSDH-12DACHANGHONG1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 56% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 57% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 11.3 (EER2)
- Below the middle
- 2CSDH-18(R)DAwith ductless indoor unit CSDH-18(R)DACHANGHONG1.5 tons · 18,000 Btu/h · DuctlessNot a cold-climate pick: keeps 63% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 64% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.2 (EER2)
- Below the middle
- 3CSDH-09LDAwith ductless indoor unit CSDH-09LDACHANGHONG1 ton · 9,000 Btu/h · DuctlessNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 56% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.50 (COP at 5°F)
- Top 10%
- Winter efficiency
- 8.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.2 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.