Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIR C vs EG4: heat pump ratings compared
Against heat pumps of the same size and type, a typical AIR C model beats 78% and a typical EG4 model 66%. AIR C rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
AIR C
78%
of similar heat pumps beaten by its typical model
Well above average11 models listed
EG4
66%
of similar heat pumps beaten by its typical model
Well above average11 models listed
- Efficiency on a 5°F dayCOP at 5°FAIR C: Beats 60%EG4: Beats 76%
- Heating power kept at 5°FCapacity at 5°F vs 47°FAIR C: Beats 85%EG4: Beats 75%
- Winter-long heating efficiencyHSPF2AIR C: Beats 88%EG4: Beats 72%
- Summer-long cooling efficiencySEER2AIR C: Beats 81%EG4: Beats 58%
- Hot-day cooling efficiencyEER2AIR C: Beats 79%EG4: Beats 65%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- AIR C
- 91%
- EG4
- 73%
Xcel CC
- AIR C
- 100%
- EG4
- 73%
CEE Advanced
- AIR C
- 0%
- EG4
- 0%
ENERGY STAR CC
- AIR C
- 0%
- EG4
- 73%
Top cold-climate picks, ductless 2 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ductless, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
AIR C
- 1UE-H24S1Pwith ductless indoor unit UI-H24MS1PAIR C2 tons · 24,000 Btu/h · DuctlessKeeps 83% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.34 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.5 (HSPF2)
- Top 10%
EG4
- 1DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)EG4Also listed as DWLC2-24KR2(US)2 tons · 22,000 Btu/h · DuctlessKeeps 116% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 116% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.05 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.0 (HSPF2)
- Great
- 2DW3B1-ACDC-24KR2(US)EG42 tons · 24,000 Btu/h · DuctlessKeeps 79% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
- 3DWB3-ACDC-24KR2(US)with ductless indoor unit DGA2-ACDC-24KR2(US)EG42 tons · 24,000 Btu/h · DuctlessKeeps 73% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.15 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view