Skip to content

Airdach vs Viessmann: heat pump ratings compared

Against heat pumps of the same size and type, a typical Airdach model beats 36% and a typical Viessmann model 60%. Viessmann rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Airdach

36%

of similar heat pumps beaten by its typical model

Well below average

43 models listed

Viessmann

60%

of similar heat pumps beaten by its typical model

Well above average

43 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAirdach: Beats 43%Viessmann: Beats 53%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAirdach: Beats 29%Viessmann: Beats 73%
  • Winter-long heating efficiencyHSPF2Airdach: Beats 25%Viessmann: Beats 74%
  • Summer-long cooling efficiencySEER2Airdach: Beats 28%Viessmann: Beats 59%
  • Hot-day cooling efficiencyEER2Airdach: Beats 48%Viessmann: Beats 50%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Airdach
    23%
    Viessmann
    84%
  • Xcel CC

    Airdach
    30%
    Viessmann
    79%
  • CEE Advanced

    Airdach
    0%
    Viessmann
    5%
  • ENERGY STAR CC

    Airdach
    0%
    Viessmann
    70%

All-around best, ducted 3.5 to 4.5 tons

Airdach

  1. 1A4TH60200MV1DGwith ducted air handler A4DH4800ME1DTAirdach4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 60.0Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    72.8score / 100Heating 60 · Cooling 86
  2. 2A3TH60180OV1DGwith ducted air handler A3DH60000OE1DTAirdach4.5 tons · 55,000 Btu/h · DuctedCold-climate pick, score 69.8Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    59.8score / 100Heating 70 · Cooling 50
  3. 3A4TH42152MN1DLwith ducted air handler A4DH4800ME1DTAirdach3.5 tons · 41,500 Btu/h · DuctedNot a cold-climate pick: keeps 49% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Great
    57.3score / 100Heating 50 · Cooling 65

Viessmann

  1. 1D5CMHAH48FAKViessmann4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    85.0score / 100Heating 83 · Cooling 87
  2. 2D5CMHAH55FAKViessmann4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    87% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.7 (HSPF2)
    Top 10%
    Cooling efficiency
    20.2 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    82.9score / 100Heating 81 · Cooling 85
  3. 3D5CUHAH48AAKwith ducted air handler D5FUHAH60XAKViessmann4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 76.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    17.5 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Great
    78.6score / 100Heating 77 · Cooling 81

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter