Skip to content

AireForce vs Bosch: heat pump ratings compared

Against heat pumps of the same size and type, a typical AireForce model beats 39% and a typical Bosch model 63%. Bosch rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

AireForce

39%

of similar heat pumps beaten by its typical model

Well below average

70 models listed

Bosch

63%

of similar heat pumps beaten by its typical model

Well above average

70 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAireForce: Beats 32%Bosch: Beats 63%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAireForce: Beats 41%Bosch: Beats 63%
  • Winter-long heating efficiencyHSPF2AireForce: Beats 39%Bosch: Beats 55%
  • Summer-long cooling efficiencySEER2AireForce: Beats 42%Bosch: Beats 55%
  • Hot-day cooling efficiencyEER2AireForce: Beats 42%Bosch: Beats 64%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    AireForce
    50%
    Bosch
    63%
  • Xcel CC

    AireForce
    49%
    Bosch
    56%
  • CEE Advanced

    AireForce
    3%
    Bosch
    10%
  • ENERGY STAR CC

    AireForce
    17%
    Bosch
    57%

All-around best, ducted 3.5 to 4.5 tons

AireForce

  1. 1UXH48-60MSK3IHwith ducted air handler UMD48MSK3IHAireForce4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 83.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Great
    80.0score / 100Heating 79 · Cooling 81
  2. 2AC-48-HP-E-32with ducted air handler AC-48-AH-E-32AireForce4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 72.3Meets none of the standards tracked here
    Heat kept at 5°F
    84% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    53.5score / 100Heating 72 · Cooling 35
  3. 3AC-60-HP-E-32with ducted air handler AC-60-AH-E-32AireForce4.5 tons · 55,000 Btu/h · DuctedCold-climate pick, score 63.0Meets none of the standards tracked here
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    48.8score / 100Heating 63 · Cooling 35

Bosch

  1. 1BOVA-60MTB-M19Ewith ducted air handler (V,R)60H210P19*+TXV+AEFE5Bosch4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 90.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    86.5score / 100Heating 85 · Cooling 88
  2. 2BOVB-60MTB-M19Ewith ducted air handler BIVB-48MCB-M19XBosch4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 85.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    85.8score / 100Heating 84 · Cooling 88
  3. 3BMS500-AAM048-1CSXRDBosch4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.6 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    85.3score / 100Heating 78 · Cooling 93

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter