Skip to content

AIRTEMP vs DiamondAir: heat pump ratings compared

One of these brands has too few models with every rating for an overall score; see each rating below.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

AIRTEMP

36%

of similar heat pumps beaten by its typical model

Well below average

47 models listed

DiamondAir

—

of similar heat pumps beaten by its typical model

Not enough rated models

7 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAIRTEMP: Beats 26%DiamondAir: Not rated
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAIRTEMP: Beats 37%DiamondAir: Not rated
  • Winter-long heating efficiencyHSPF2AIRTEMP: Beats 30%DiamondAir: Beats 26%
  • Summer-long cooling efficiencySEER2AIRTEMP: Beats 35%DiamondAir: Beats 21%
  • Hot-day cooling efficiencyEER2AIRTEMP: Beats 46%DiamondAir: Beats 62%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    AIRTEMP
    43%
    DiamondAir
    0%
  • Xcel CC

    AIRTEMP
    40%
    DiamondAir
    0%
  • CEE Advanced

    AIRTEMP
    4%
    DiamondAir
    0%
  • ENERGY STAR CC

    AIRTEMP
    26%
    DiamondAir
    0%

All-around best, ducted up to 1.5 tons

AIRTEMP

  1. 1DXH18FMK3IHAIRTEMP1.5 tons · 16,000 Btu/h · DuctedCold-climate pick, score 40.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.86 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    41.2score / 100Heating 41 · Cooling 42
  2. 2VSH4BE5M1SP18Kwith indoor coil C75B(A,H)MX24C*A and furnace VG7S(*)-(*)A(*)AIRTEMP1.5 tons · 17,800 Btu/h · DuctedNot a cold-climate pick: keeps 44% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    47% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    21.5score / 100Heating 16 · Cooling 28

DiamondAir

None of DiamondAir’s ducted, up to 1.5 tons models has all five ratings.

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter