APLUS vs Endura: heat pump ratings compared

Against heat pumps of the same size and type, a typical APLUS model beats 18% and a typical Endura model 64%. Endura rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

APLUS

18%

of similar heat pumps beaten by its typical model

Well below average

32 models listed

Endura

64%

of similar heat pumps beaten by its typical model

Well above average

9 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAPLUS: Beats 19%Endura: Beats 47%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAPLUS: Beats 7%Endura: Beats 74%
  • Winter-long heating efficiencyHSPF2APLUS: Beats 22%Endura: Beats 57%
  • Summer-long cooling efficiencySEER2APLUS: Beats 22%Endura: Beats 69%
  • Hot-day cooling efficiencyEER2APLUS: Beats 51%Endura: Beats 67%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    APLUS
    0%
    Endura
    100%
  • Xcel CC

    APLUS
    0%
    Endura
    100%
  • CEE Advanced

    APLUS
    0%
    Endura
    0%
  • ENERGY STAR CC

    APLUS
    0%
    Endura
    100%

All-around best, ducted 3.5 to 4.5 tons

APLUS

  1. 1ART-HF48SSMR3-C01/SE134APLUS3.5 tons · 44,500 Btu/h · DuctedNot a cold-climate pick: keeps 40% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    41% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.86 (COP at 5°F)
    Below the middle
    Winter efficiency
    6.7 (HSPF2)
    Below the middle
    Cooling efficiency
    13.4 (SEER2)
    Below the middle
    Hot-day cooling
    11.2 (EER2)
    Good
    25.0score / 100Heating 17 · Cooling 33
  2. 2ART-HF60SSMR3-C01/SE134APLUS4.5 tons · 53,500 Btu/h · DuctedNot a cold-climate pick: keeps 42% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    42% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    6.7 (HSPF2)
    Below the middle
    Cooling efficiency
    13.4 (SEER2)
    Below the middle
    Hot-day cooling
    10.8 (EER2)
    Below the middle
    22.4score / 100Heating 20 · Cooling 25

Endura

  1. 1HBEFU-48R454Bwith ducted air handler HBEC-FC48R454BEndura4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 77.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    77% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.52 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    82.6score / 100Heating 77 · Cooling 88
  2. 2HBEFLM5-OD42Endura3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 50.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    11.4 (EER2)
    Good
    60.1score / 100Heating 51 · Cooling 69

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.