Skip to content

ApooDr vs YITAHOME: heat pump ratings compared

Against heat pumps of the same size and type, a typical ApooDr model beats 59% and a typical YITAHOME model 35%. ApooDr rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

ApooDr

59%

of similar heat pumps beaten by its typical model

Above average

44 models listed

YITAHOME

35%

of similar heat pumps beaten by its typical model

Well below average

43 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FApooDr: Beats 64%YITAHOME: Beats 71%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FApooDr: Beats 46%YITAHOME: Beats 14%
  • Winter-long heating efficiencyHSPF2ApooDr: Beats 66%YITAHOME: Beats 22%
  • Summer-long cooling efficiencySEER2ApooDr: Beats 65%YITAHOME: Beats 39%
  • Hot-day cooling efficiencyEER2ApooDr: Beats 55%YITAHOME: Beats 28%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    ApooDr
    91%
    YITAHOME
    47%
  • Xcel CC

    ApooDr
    75%
    YITAHOME
    12%
  • CEE Advanced

    ApooDr
    0%
    YITAHOME
    0%
  • ENERGY STAR CC

    ApooDr
    77%
    YITAHOME
    0%

All-around best, ductless 2 tons

ApooDr

  1. 1ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN1ApooDr2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 75.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    22.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    68.9score / 100Heating 76 · Cooling 62
  2. 2AM4OJ-27HFN1ApooDr2 tons · 26,000 Btu/h · DuctlessCold-climate pick, score 43.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    12.2 (EER2)
    Good
    59.0score / 100Heating 43 · Cooling 75
  3. 3ASG24-24H1Bwith ductless indoor unit ASG24-24H1AApooDr2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 54.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.13 (COP at 5°F)
    Great
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    54.9score / 100Heating 55 · Cooling 55

YITAHOME

  1. 1IMHCAC-0034YITAHOME2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 68.5Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    12.5 (EER2)
    Good
    73.3score / 100Heating 69 · Cooling 78
  2. 2IMHCAC-0014with ductless indoor unit IMHCAC-0013YITAHOME2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 63% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    64% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    50.6score / 100Heating 46 · Cooling 55
  3. 3YSAA24DL2AU-Wwith ductless indoor unit YSAA24DL2AU-NYITAHOMEAlso listed as YSAA24DN2AU-W, YSAA24DT2AU-W, YSAA24DR2AU-W, YSAA24DH2AU-W2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 53% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    53% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.9 (EER2)
    Below the middle
    34.5score / 100Heating 34 · Cooling 36

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter