Skip to content

Armbridge vs KLIMAIRE: heat pump ratings compared

Against heat pumps of the same size and type, a typical Armbridge model beats 52% and a typical KLIMAIRE model 54%. KLIMAIRE rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Armbridge

52%

of similar heat pumps beaten by its typical model

About average

29 models listed

KLIMAIRE

54%

of similar heat pumps beaten by its typical model

About average

29 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FArmbridge: Beats 42%KLIMAIRE: Beats 48%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FArmbridge: Beats 46%KLIMAIRE: Beats 49%
  • Winter-long heating efficiencyHSPF2Armbridge: Beats 61%KLIMAIRE: Beats 61%
  • Summer-long cooling efficiencySEER2Armbridge: Beats 63%KLIMAIRE: Beats 62%
  • Hot-day cooling efficiencyEER2Armbridge: Beats 46%KLIMAIRE: Beats 49%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Armbridge
    52%
    KLIMAIRE
    72%
  • Xcel CC

    Armbridge
    48%
    KLIMAIRE
    69%
  • CEE Advanced

    Armbridge
    3%
    KLIMAIRE
    0%
  • ENERGY STAR CC

    Armbridge
    31%
    KLIMAIRE
    0%

All-around best, ducted 2.5 to 3 tons

Armbridge

  1. 1AB-GTMH36-230VOArmbridge3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 66.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    94% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    21.5 (SEER2)
    Top 10%
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    81.4score / 100Heating 66 · Cooling 97
  2. 2AB-GTMR30-230VOArmbridge2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 73.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    77% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    80.8score / 100Heating 74 · Cooling 88
  3. 3AB-GTMR36-230VOArmbridge3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 70.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.6 (EER2)
    Good
    72.8score / 100Heating 70 · Cooling 75

KLIMAIRE

  1. 1KMHR536-H224-4KLIMAIRE3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.7Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    106% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.4 (HSPF2)
    Top 10%
    Cooling efficiency
    19.4 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    83.9score / 100Heating 83 · Cooling 85
  2. 2KMHR427-H225-4KLIMAIRE2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 73.1Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    77.8score / 100Heating 73 · Cooling 83
  3. 3KMIR536-H224-4KLIMAIRE3 tons · 35,000 Btu/h · DuctedCold-climate pick, score 60.5Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    70.0score / 100Heating 61 · Cooling 80

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter