Skip to content

Bestcold vs Della: heat pump ratings compared

Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical Della model 49%. Della rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Bestcold

46%

of similar heat pumps beaten by its typical model

About average

96 models listed

Della

49%

of similar heat pumps beaten by its typical model

About average

97 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 43%Della: Beats 43%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 46%Della: Beats 46%
  • Winter-long heating efficiencyHSPF2Bestcold: Beats 47%Della: Beats 51%
  • Summer-long cooling efficiencySEER2Bestcold: Beats 51%Della: Beats 57%
  • Hot-day cooling efficiencyEER2Bestcold: Beats 40%Della: Beats 42%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Bestcold
    66%
    Della
    68%
  • Xcel CC

    Bestcold
    63%
    Della
    66%
  • CEE Advanced

    Bestcold
    1%
    Della
    0%
  • ENERGY STAR CC

    Bestcold
    22%
    Della
    42%

All-around best, ductless 2 tons

Bestcold

  1. 1MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-IBestcold2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 59.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    93% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    58.5score / 100Heating 59 · Cooling 58
  2. 2MYTW24NA23BCH24ES-Owith ductless indoor unit MYTW24NA23BCH24ES-IBestcoldAlso listed as MYTD24NA23BCH24-O2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 39.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    51.4score / 100Heating 40 · Cooling 63
  3. 3MYTW24NA23BCH20/Owith ductless indoor unit MYTW24NA23BCH20/IBestcold2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 68% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    68% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Good
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    43.1score / 100Heating 48 · Cooling 38

Della

  1. 1048-MS-24K2VR-22S-M-OUTwith ductless indoor unit 048-MS-24K2VR-22S-M-INDellaAlso listed as 048-MS-24K2VR-22S-MX-OUT2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 78.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    87% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    22.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    70.2score / 100Heating 79 · Cooling 62
  2. 2048-TP-23K2V-23S-OUTwith ductless indoor unit 048-CC-24K2V-INDella2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 63.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.4 (HSPF2)
    Great
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    60.9score / 100Heating 64 · Cooling 58
  3. 3048-MS-24K2VR-21S-OUTwith ductless indoor unit 048-MS-24K2VR-21S-QC-INDella2 tons · 22,000 Btu/h · DuctlessNot a cold-climate pick: keeps 24% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    24% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.27 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Great
    60.2score / 100Heating 53 · Cooling 67

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter