Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Bestcold vs REVOLV: heat pump ratings compared
Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical REVOLV model 17%. Bestcold rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Bestcold
46%
of similar heat pumps beaten by its typical model
About average79 models listed
REVOLV
17%
of similar heat pumps beaten by its typical model
Well below average11 models listed
- Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 45%REVOLV: Beats 7%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 43%REVOLV: Beats 13%
- Winter-long heating efficiencyHSPF2Bestcold: Beats 48%REVOLV: Beats 17%
- Summer-long cooling efficiencySEER2Bestcold: Beats 51%REVOLV: Beats 13%
- Hot-day cooling efficiencyEER2Bestcold: Beats 39%REVOLV: Beats 32%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Bestcold
- 68%
- REVOLV
- 0%
Xcel CC
- Bestcold
- 66%
- REVOLV
- 0%
CEE Advanced
- Bestcold
- 1%
- REVOLV
- 0%
ENERGY STAR CC
- Bestcold
- 10%
- REVOLV
- 0%
All-around best, ducted 2 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
Bestcold
- 1MYGA36NA23BCH19-Owith ducted air handler MYGA24NA23BCH20-IBestcold2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 67.2Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.4 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.3 (EER2)
- Top 10%
- 2MYUA24NA23BCH20-Owith ducted air handler MYUA24NA23BCH20-IBestcold2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 65.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 14.0 (EER2)
- Top 10%
- 3MYUSA24NA23BCH19-Owith ducted air handler MYUSA24NA23BCH19-IBestcold2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 80.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 18.5 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
REVOLV
- 1HSH4ME5M1SP24Kwith indoor coil C75B(A,H)MX24C*B and furnace MG3P-054U1AABREVOLV2 tons · 23,400 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 51% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 14.3 (SEER2)
- Below the middle
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 2Q95RD*024KREVOLV2 tons · 23,600 Btu/h · DuctedNot a cold-climate pick: keeps 35% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 35% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.50 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.4 (SEER2)
- Below the middle
- Hot-day cooling
- 10.6 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.