Skip to content

Bestcold vs THERMAL ZONE: heat pump ratings compared

Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical THERMAL ZONE model 30%. Bestcold rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Bestcold

46%

of similar heat pumps beaten by its typical model

About average

96 models listed

THERMAL ZONE

30%

of similar heat pumps beaten by its typical model

Well below average

101 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 43%THERMAL ZONE: Beats 39%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 46%THERMAL ZONE: Beats 25%
  • Winter-long heating efficiencyHSPF2Bestcold: Beats 47%THERMAL ZONE: Beats 22%
  • Summer-long cooling efficiencySEER2Bestcold: Beats 51%THERMAL ZONE: Beats 24%
  • Hot-day cooling efficiencyEER2Bestcold: Beats 40%THERMAL ZONE: Beats 32%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Bestcold
    66%
    THERMAL ZONE
    8%
  • Xcel CC

    Bestcold
    63%
    THERMAL ZONE
    8%
  • CEE Advanced

    Bestcold
    1%
    THERMAL ZONE
    0%
  • ENERGY STAR CC

    Bestcold
    22%
    THERMAL ZONE
    8%

All-around best, ducted 2.5 to 3 tons

Bestcold

  1. 1MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-IBestcold3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 70.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    11.3 (EER2)
    Below the middle
    66.2score / 100Heating 70 · Cooling 62
  2. 2MYUSA36NA23BCH18-Owith ducted air handler MYUSA36NA23BCH18-IBestcold3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 69.3Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    60.5score / 100Heating 69 · Cooling 52
  3. 3MYOA36NA22BCH18-Owith ducted air handler MYOA36NA22BCH18-IBestcold3 tons · 33,000 Btu/h · DuctedCold-climate pick, score 59.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    11.2 (EER2)
    Below the middle
    58.3score / 100Heating 59 · Cooling 57

THERMAL ZONE

  1. 1TZP15AY36AJ2Nwith ducted air handler AEW37J+TDRTHERMAL ZONE2.5 tons · 31,600 Btu/h · DuctedCold-climate pick, score 72.5Meets none of the standards tracked here
    Heat kept at 5°F
    102% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.66 (COP at 5°F)
    Top 10%
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    14.5 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    59.1score / 100Heating 73 · Cooling 46
  2. 2TZID30H520ZCSwith ducted air handler TZID30H520ZAMTHERMAL ZONE2.5 tons · 30,000 Btu/h · DuctedNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    62% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Good
    Hot-day cooling
    10.7 (EER2)
    Below the middle
    44.8score / 100Heating 49 · Cooling 41
  3. 3TZID36H520ZCSwith ducted air handler TZID36H520ZAMTHERMAL ZONE3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 59.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    16.1 (SEER2)
    Below the middle
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    44.2score / 100Heating 60 · Cooling 28

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter