Both views use the same certified data. This device remembers your choice.
Bestcold vs THERMAL ZONE: heat pump ratings compared
Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical THERMAL ZONE model 30%. Bestcold rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Bestcold
46%
of similar heat pumps beaten by its typical model
About average96 models listed
THERMAL ZONE
30%
of similar heat pumps beaten by its typical model
Well below average101 models listed
- Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 43%THERMAL ZONE: Beats 39%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 46%THERMAL ZONE: Beats 25%
- Winter-long heating efficiencyHSPF2Bestcold: Beats 47%THERMAL ZONE: Beats 22%
- Summer-long cooling efficiencySEER2Bestcold: Beats 51%THERMAL ZONE: Beats 24%
- Hot-day cooling efficiencyEER2Bestcold: Beats 40%THERMAL ZONE: Beats 32%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Bestcold
- 66%
- THERMAL ZONE
- 8%
Xcel CC
- Bestcold
- 63%
- THERMAL ZONE
- 8%
CEE Advanced
- Bestcold
- 1%
- THERMAL ZONE
- 0%
ENERGY STAR CC
- Bestcold
- 22%
- THERMAL ZONE
- 8%
All-around best, ducted 5 tons and up
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
Bestcold
No ducted, 5 tons and up model from Bestcold.
THERMAL ZONE
- 1TZP15AY60AJ2Nwith ducted air handler TZHDYTST6024*NANTHERMAL ZONE5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 50% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 7.8 (HSPF2)
- Good
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2TZP14AY60AJ2Nwith indoor coil TCFY6024STANM and furnace TZ80UH1V100C5STHERMAL ZONE5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 61% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 45% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.8 (HSPF2)
- Good
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3RHPCYC060ACTHERMAL ZONEAlso listed as RHPCYC060AD5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 46% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 46% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 16.1 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view