Both views use the same certified data. This device remembers your choice.
BHI vs Bluefin: heat pump ratings compared
Against heat pumps of the same size and type, a typical BHI model beats 18% and a typical Bluefin model 43%. Bluefin rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
BHI
18%
of similar heat pumps beaten by its typical model
Well below average7 models listed
Bluefin
43%
of similar heat pumps beaten by its typical model
Below average7 models listed
- Efficiency on a 5°F dayCOP at 5°FBHI: Beats 24%Bluefin: Beats 51%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBHI: Beats 17%Bluefin: Beats 26%
- Winter-long heating efficiencyHSPF2BHI: Beats 38%Bluefin: Beats 37%
- Summer-long cooling efficiencySEER2BHI: Beats 10%Bluefin: Beats 53%
- Hot-day cooling efficiencyEER2BHI: Beats 12%Bluefin: Beats 43%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- BHI
- 14%
- Bluefin
- 71%
Xcel CC
- BHI
- 14%
- Bluefin
- 43%
CEE Advanced
- BHI
- 0%
- Bluefin
- 0%
ENERGY STAR CC
- BHI
- 0%
- Bluefin
- 43%
All-around best, ductless up to 1.5 tons
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
BHI
- 1BHI-*12K115V-USwith ductless indoor unit BHI-*12K115V-USBHI1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 39.7Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 10.5 (EER2)
- Below the middle
- 2BHI-*T17-12K115V-USwith ductless indoor unit BHI-*T17-12K115V-USBHIAlso listed as BHI-T17-12K115V-US1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 69% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
- 3BHI-T17-18K230V-USwith ductless indoor unit BHI-T17-18K230V-USBHI1.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 57% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 58% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
Bluefin
- 1BFMS09BA-02Owith ductless indoor unit BFMS09BA-02IBluefin1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 41.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Good
- Winter efficiency
- 9.4 (HSPF2)
- Below the middle
- Cooling efficiency
- 21.6 (SEER2)
- Good
- Hot-day cooling
- 12.6 (EER2)
- Good
- 2BFMS18BA-02Owith ductless indoor unit BFMS18BA-02IBluefin1.5 tons · 18,000 Btu/h · DuctlessNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 61% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Good
- Winter efficiency
- 9.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 20.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Below the middle
- 3BFMS12BA-02Owith ductless indoor unit BFMS12BA-02IBluefin1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 21.3 (SEER2)
- Good
- Hot-day cooling
- 10.8 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view