Skip to content

Bluefin vs DANBY: heat pump ratings compared

Against heat pumps of the same size and type, a typical Bluefin model beats 43% and a typical DANBY model 55%. DANBY rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Bluefin

43%

of similar heat pumps beaten by its typical model

Below average

7 models listed

DANBY

55%

of similar heat pumps beaten by its typical model

About average

7 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FBluefin: Beats 51%DANBY: Beats 48%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBluefin: Beats 26%DANBY: Beats 49%
  • Winter-long heating efficiencyHSPF2Bluefin: Beats 37%DANBY: Beats 70%
  • Summer-long cooling efficiencySEER2Bluefin: Beats 53%DANBY: Beats 63%
  • Hot-day cooling efficiencyEER2Bluefin: Beats 43%DANBY: Beats 44%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Bluefin
    71%
    DANBY
    86%
  • Xcel CC

    Bluefin
    43%
    DANBY
    86%
  • CEE Advanced

    Bluefin
    0%
    DANBY
    0%
  • ENERGY STAR CC

    Bluefin
    43%
    DANBY
    29%

All-around best, ductless up to 1.5 tons

Bluefin

  1. 1BFMS09BA-02Owith ductless indoor unit BFMS09BA-02IBluefin1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 41.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.99 (COP at 5°F)
    Good
    Winter efficiency
    9.4 (HSPF2)
    Below the middle
    Cooling efficiency
    21.6 (SEER2)
    Good
    Hot-day cooling
    12.6 (EER2)
    Good
    51.4score / 100Heating 41 · Cooling 62
  2. 2BFMS18BA-02Owith ductless indoor unit BFMS18BA-02IBluefin1.5 tons · 18,000 Btu/h · DuctlessNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    61% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.99 (COP at 5°F)
    Good
    Winter efficiency
    9.1 (HSPF2)
    Below the middle
    Cooling efficiency
    20.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.5 (EER2)
    Below the middle
    36.9score / 100Heating 35 · Cooling 39
  3. 3BFMS12BA-02Owith ductless indoor unit BFMS12BA-02IBluefin1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Below the middle
    Cooling efficiency
    21.3 (SEER2)
    Good
    Hot-day cooling
    10.8 (EER2)
    Below the middle
    33.0score / 100Heating 26 · Cooling 40

DANBY

  1. 1DAS090AGBAHWDB-Owith ductless indoor unit DAS090AGBAHWDB-IDANBY1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 86.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.33 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.0 (HSPF2)
    Top 10%
    Cooling efficiency
    24.6 (SEER2)
    Great
    Hot-day cooling
    14.7 (EER2)
    Top 10%
    87.7score / 100Heating 87 · Cooling 89
  2. 2DAS120AGBAHWDB-Owith ductless indoor unit DAS120AGBAHWDB-IDANBY1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 74.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.36 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.5 (HSPF2)
    Top 10%
    Cooling efficiency
    23.1 (SEER2)
    Great
    Hot-day cooling
    12.2 (EER2)
    Good
    69.1score / 100Heating 74 · Cooling 64
  3. 3DAS180ESHH1WDB-Owith ductless indoor unit DAS180ESHH1WDB-IDANBY1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 52.8Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    58.5score / 100Heating 53 · Cooling 64

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.