Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BlueRidge vs Midea: heat pump ratings compared
Against heat pumps of the same size and type, a typical BlueRidge model beats 56% and a typical Midea model 59%. Midea rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
BlueRidge
56%
of similar heat pumps beaten by its typical model
Above average192 models listed
Midea
59%
of similar heat pumps beaten by its typical model
Above average546 models listed
- Efficiency on a 5°F dayCOP at 5°FBlueRidge: Beats 57%Midea: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBlueRidge: Beats 55%Midea: Beats 56%
- Winter-long heating efficiencyHSPF2BlueRidge: Beats 60%Midea: Beats 66%
- Summer-long cooling efficiencySEER2BlueRidge: Beats 58%Midea: Beats 61%
- Hot-day cooling efficiencyEER2BlueRidge: Beats 54%Midea: Beats 54%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- BlueRidge
- 76%
- Midea
- 76%
Xcel CC
- BlueRidge
- 68%
- Midea
- 70%
CEE Advanced
- BlueRidge
- 4%
- Midea
- 3%
ENERGY STAR CC
- BlueRidge
- 65%
- Midea
- 64%
All-around best, ducted 5 tons and up
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
BlueRidge
- 1BH714S60P-**Awith ducted air handler BAH7V60PT-BlueRidge5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 53% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 54% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.24 (COP at 5°F)
- Top 10%
- Winter efficiency
- 8.1 (HSPF2)
- Good
- Cooling efficiency
- 14.7 (SEER2)
- Below the middle
- Hot-day cooling
- 12.2 (EER2)
- Top 10%
- 2BMS60UYCwith ducted air handler BMS60HCDBlueRidgeAlso listed as BXL1A60SC05 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
- 3BMMZ60CBlueRidgeAlso listed as BXM1A60SC05 tons · 60,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.2 (HSPF2)
- Great
- Cooling efficiency
- 18.0 (SEER2)
- Great
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
Midea
- 1MRD-60HWD1N10-M18GMideaAlso listed as MRD-60HWD1N10-M18GB5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 63.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.2 (EER2)
- Good
- 237MBRAQ58AA3with ducted air handler 45MBDAQ58XH3Midea5 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
- 3D5CLRAH58AAKwith ducted air handler D5FLDAH58XHKMideaAlso sold as MDV MOE30-60HFN10-M25 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view